EEWORLDEEWORLDEEWORLD

Part Number

Search

3838P100KRN362XC

Description
Ceramic Capacitor, Ceramic, 3600V, 10% +Tol, 10% -Tol, P90, 90+/-20ppm/Cel TC, 0.00001uF, Through Hole Mount, RADIAL LEADED
CategoryPassive components    capacitor   
File Size754KB,6 Pages
ManufacturerPassive Plus Inc
Download Datasheet Parametric View All

3838P100KRN362XC Overview

Ceramic Capacitor, Ceramic, 3600V, 10% +Tol, 10% -Tol, P90, 90+/-20ppm/Cel TC, 0.00001uF, Through Hole Mount, RADIAL LEADED

3838P100KRN362XC Parametric

Parameter NameAttribute value
Objectid7050368328
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSTANDARD: MIL-PRF-55681; MIL-PRF-123
capacitance0.00001 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
JESD-609 codee4
Installation featuresTHROUGH HOLE MOUNT
multi-layerNo
negative tolerance10%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
method of packingWAFFLE PACK
positive tolerance10%
Rated (DC) voltage (URdc)3600 V
surface mountNO
Temperature characteristic codeP90
Temperature Coefficient90+/-20ppm/Cel ppm/°C
Terminal surfaceSilver (Ag)
Terminal shapeWIRE
Traditional High Q (>10,000) Low ESR Capacitors
3838C/P (.380” x .380”)
3838C/P (.380” x .380”)
Product
Features
High Q, High RF Current/Voltage, High RF Power, Low ESR/ESL, Low Noise,
Ultra-Stable Performance.
Product Application
Typical Functional Applications: Bypass, Coupling, Tuning, Impedance Matching and D.C. Blocking.
Typical Circuit Applications: HF/RF Power Amplifiers, Transmitters, Antenna Tuning,
Plasma Chambers, and Medical.
3838C/P Capacitance Table
Cap.
Code
pF
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
1.9
2.0
2.1
2.2
2.4
2.7
3.0
0R5
0R6
0R7
0R8
0R9
1R0
1R1
1R2
1R3
1R4
1R5
1R6
1R7
1R8
1R9
2R0
2R1
2R2
1R9
2R0
2R1
2R2
2R4
2R7
3R0
B,
C,D
3600V
Code
362
or
7200V
Code
722
Tol.
Rated Cap.
Code
WVDC pF
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
20
22
24
27
30
33
3R3
3R6
3R9
4R3
4R7
5R1
5R6
6R2
6R8
7R5
8R2
9R1
100
110
120
130
150
160
180
200
220
240
270
300
330
NP0= C; P90=P
Tol.
Rated Cap.
Code
WVDC pF
36
39
43
47
B,
C,D
51
56
62
68
75
3600V
Code
362
or
7200V
Code
722
82
91
100
110
120
130
150
160
F,G,
J,K
180
200
220
240
270
300
330
360
360
390
430
470
510
560
620
680
750
820
910
101
111
121
131
151
161
181
201
221
241
271
301
331
361
F,G,
J,K
3600V
Code
362
or
5000V
Code
502
3600V
Code
362
or
7200V
Code
722
Tol.
Rated Cap.
Code
WVDC pF
390
430
470
510
560
620
680
750
820
910
1000
1100
1200
1500
1800
2200
2400
2700
3000
3300
3600V 3600
Code 3900
362 4300
4700
5100
391
431
471
511
561
621
681
751
821
911
102
112
122
152
182
222
242
272
302
332
362
392
432
472
512
500V
Code
501
F,G,
J,K
1000V
Code
102
2500V
Code
252
Tol.
Rated
WVDC
Remark: special capacitance, tolerance and WVDC are available, consult with PASSIVE PLUS.
www.passiveplus.com
(631) 425-0938
sales@passsiveplus.com
Problems with selecting serial port chip for CC2530
I recently bought a CC2530 module from the Internet and found that it uses the PL2303 UART to USB chip. This chip can choose the input voltage of 2.4V or 3.3V, but I want to use the RS232 chip now. Th...
mayulin2008 RF/Wirelessly
interview
After I learned Linux+C, I wondered whether it would be more promising to develop in the embedded field or in the network programming (TCP/IP and socket) field. I have successfully interviewed two com...
cosmowang Embedded System
About CAN communication
Communication - combined with the book, there are the following contents: Digital logic of CAN communication, implicit level 1, dominant level 0CAN communication frames are divided into data frames, r...
fish001 DSP and ARM Processors
I am taking the computer science postgraduate exam this year. I don't know whether to choose embedded technology or programming? Please give me some advice.
I graduated from computer science and took the postgraduate entrance examination for computer application this year. I originally chose embedded technology. In fact, I don’t know much about this field...
zmz.558 Embedded System
The problem of rs485 networking in the meter reading system is urgent! ! ! ! !
Now we are making a meter reading system. Each meter controller has a 485 communication port. However, there are usually more than 50 meters in a building. A 485 bus network can connect up to 32 meter...
x02004514 Embedded System
[DIY] The story of the alarm clock rechargeable battery power supply solution 2
I have to say that the previous method still doesn't work. I have always felt very strange about this. I just read the posts and thought that one of the posts by a buddy is worth noting. However, I am...
辛昕 DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 973  1576  59  220  651  20  32  2  5  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号