EEWORLDEEWORLDEEWORLD

Part Number

Search

125C35-B2M-02-KB

Description
Non-Linear Resistor
CategoryPassive components    The resistor   
File Size65KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

125C35-B2M-02-KB Overview

Non-Linear Resistor

125C35-B2M-02-KB Parametric

Parameter NameAttribute value
Objectid402313755
Reach Compliance Codeunknown
ECCN codeEAR99
Bussmann
®
SHORTSTOP
®
Auto, Manual & Modified Reset Circuit Protectors
Series 120
SPECIFICATIONS
Single Pole Thermal Type Breakers
Ratings:
8A to 50A; 12 VDC; 24 VDC.
Operating Temperature:
–10°F (–23°C) to 150°F (65°C).
Storage Temperature:
–20°F (–29°C) to 200°F (93°C).
Applications:
Battery chargers, trucks, buses, RV’s, trolling motors, etc.
Approvals:
Complies with SAE Standard J553.
TEMPERATURE DERATING CURVES
200%
% 0F RATED CURRENT
% 0F RATED CURRENT
150%
100%
50%
0%
-50º
Two 10-32 studs:
.66" (AUX); .56" (BAT)
.69"
(17.5)
Two 10-32 studs:
.56" (AUX & BAT)
.99"
(25.2)
.66"
(16.8)
TIME VS. PERCENT OF RATED CURRENT
600%
500%
400%
300%
200%
100%
0
5
10 15
20 30 40 100 200 500
TIME IN SECONDS
Terminal Options
.69"
(17.5)
.66"
(16.8)
.69"
(17.5)
.56"
(14.2)
A
B
.56"
(14.2)
50º 77º 100º 150º
200º
TEMPERATURE IN DEGREES F.
250º
C
D
.41"
(10.3)
Cover & Bracket Options
METAL COVER
1.24"
(31.5)
.79"
(20.1)
1.56"
(39.6)
.38" (9.6)
1.24"
(31.5)
.79"
(20.1)
PLASTIC COVER
1.27"
(32.3)
.83" 1.56"
(21.1) (39.6)
.62"
(15.7)
O Bracket
1.56"
(39.6)
.83"
1.27" (21.1)
(32.3)
A Bracket
.37" (9.4)
.37" (9.4)
Two 10-32 studs:
.66" (AUX & BAT)
.84"
(21.4)
.41"
(10.3)
Two .25" Q.C.
(AUX & BAT)
.69"
(17.5)
E
.56"
(14.2)
.41"
(10.3)
H
.56"
(14.2)
One .25" Q.C. (AUX);
One 10-32 stud (BAT)
.99"
(25.2)
.30"
(7.7)
Double .25" Q.C. (AUX);
One 10-32 stud (BAT)
.84"
(21.4)
.64"
(16.3)
O Bracket
.69"
(17.5)
A Bracket
.79"
1.24"
(31.5) (20.1)
1.27"
(32.2)
B Bracket
.12" (3.0)
dia. boss
1.27"
(32.2)
C Bracket
J
.41"
(10.3)
K
.83"
(21.1)
.54"
(13.7)
1.56"
(39.6)
.79"
(20.1)
1.24"
(31.5)
.69"
(17.5)
B Bracket
Double .25" Q.C. (AUX);
Single .25" Q.C. (BAT)
.69"
(17.5)
Two .25" Q.C. (AUX & BAT)
Perpendicular
Orientation
Reset button
.06"
(1.5)
.62"
(15.7)
1.27"
(32.3)
.83"
(21.1)
.38" (9.6)
1.56"
(39.6)
L
.37" (9.4)
.69"
(17.5)
C Bracket
Two 10-32 studs
(AUX & BAT)
.62" (15.7)
Ref. (Typ)
w/base attached
E Bracket
Series 123
O Bracket w/reset
PART NUMBERING SYSTEM
Series
Terminal
Rating
Bracket
Mtg. Holes
Cover*
Options
Hardware
1 2
ttt
t
tt
t
O – No bracket
A – Bracket
B – Bracket
C – Bracket
E – Bracket
(plastic only)
t
0 – No bracket
1 – .140 dia.
2 – .196 dia.
3 – .237 dia.
(metal only)
4 – .265 dia.
(plastic only)
5 – .228 dia.
(plastic only)
6 – .221 dia.
(metal only)
t
tt
tt
M – Metal
P – Plastic
01 – Waterproof
(metal
covers only)
02 – Splashproof
(optional on
metal covers -
add 02 suffix;
std. on plastic
covers - omit
02 suffix.)
WA – Whiz-lock nut
assembled
WB – Whiz-lock
nut bulk un-
assembled
HA – Nut & lock
washer
assembled
HB – Nut & lock
washer bulk
unassembled
KA – Keps lock nut
assembled
KB – Keps lock
nut bulk
unassembled
121 – Auto Reset
08 – 8 amps
A – Two 10-32 studs;
12 VDC
10 – 10 amps
.66 (Aux), .56 (Bat)
122 – Modified
12 – 12 amps
B – Two 10-32 studs;
12 VDC
15 – 15 amps
.56 (Aux & Bat)
123 – Manual
20 – 20 amps
C – Two 10-32 studs;
24 VDC
25 – 25 amps
.66 (Aux & Bat)
115 VAC
30 – 30 amps
***D – Two .250 QC;
124 – Auto
35 – 35 amps
(Aux & Bat)
24 VDC
***E – One .250 QC (Aux); 40 – 40 amps
125 – Modified
One 10-32 stud (Bat) 50 – 50 amps
24 VDC
** H – One 10-32 stud
.56 (Bat), Double
.250 QC (Aux)
***J – Single .250 QC (Bat)
Double .250 QC (Aux)
***K – Two .250 QC (Aux & Bat)
L – Two 10-32 studs; .37 (Aux & Bat)
* Series 123 available in plastic cover only. Series
122 & 125 available in metal cover only.
** 40A maximum
*** 30A maximum
12-16-98
SB98107 Rev. A
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies
of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide
technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design
or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or
update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the
user in all possible applications.
Form No. 120 ShortStop
Page 1 of 1
BIF Document: 2067
The TouchGFX Designer is a real pain
Some time ago, I was using TouchGFX Designer to create a project. At that time, I was using 4G Internet access at home, and the creation often failed. Sometimes I spent the whole day downloading routi...
littleshrimp Integrated technical exchanges
MC34063 application seeks a solution
How to convert 5V to positive and negative 12V using MC34063? How to calculate the resistance and capacitance ? The manual does not give the corresponding values. I should look for them there....
dianzijie5 Power technology
EBOOT interrupt problem? ?
I want to implement an interrupt in EBOOT. I did it according to the USB interrupt. I can enter the interrupt, but after the interrupt is executed, I can't return to the place where the interrupt was ...
niuxiaofeng Embedded System
Help: PB6.0 network download NK failed?
I want to download NK.BIN file via ETHERNET in PB6.0, and the development board is imx35. EBOOT on the development board sends SEND ME UDP packet normally, and the name of the development board can be...
excellence Embedded System
The confusion of a developer over thirty years old
I am over thirty years old and have been engaged in software development for ten years. During this period, I have experienced changes in various languages and development models. After going through ...
小威 Embedded System
How to implement analog serial communication with TI MSP430
1. Background: In many cases, due to limited hardware resources, but serial communication is needed, you can consider using an analog serial port; 2. Prerequisites: To achieve a specific bps serial po...
Aguilera Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1867  1449  2213  1231  2508  38  30  45  25  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号