The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
Ribbon Cable connector Compliant with MIL Standard
HIF3B Series
sFeatures
1. Product Compliant with MIL Standard
HIF3B series has been developed as a product compliant with MIL
standard, and used for wide applications.
2. UL Approval Product
HIF3B series connectors are UL approved.
3. Mechanism to Prevent Mis-insertion
This connector is equipped with the mechanism to prevent Mis-
insertion as follows.
1
The system provides the convex area to insert the guide-key on the
pin header side, and to guide it in combination with the socket
convex area (MIL standard).
2
The system embeds and guides the polarizing key in the socket holes.
4. Applicable Cable AWG#28
The applicable cable is UL2651 AWG#28 flat cable (7 cores./
0.127mm, jacket dia. 0.9±0.1mm).
sProduct
Specifications
Rating
Current rating : 1A
Operating Temperature Range :
–55 to +85ç
(Note 1) Storage Temperature Range :
–10 to +60ç
(Note 2)
Storage Humidity Range : 40
to
70% (Note 2)
Condition
500V DC
650V AC/1 minute
0.1A
Voltage rating : 200V AC Operating Moisture Range : 40
to
80%
Item
1. Insulation Resistance
2. Withstanding voltage
3. Contact Resistance
4. Vibration
1000M
ohms
min.
Specification
No flashover or insulation breakdown.
15m
ohms
max.
No electrical discontinuity of 1µs or more
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 directions.
96 hours at temperature of 40ç and humidity of 90% to 95%
No deformation of components affecting performance.
Flow: 260ç for 10 seconds
Manual soldering: 300ç for 3 seconds
Note 1: Includes temperature rise caused by current flow.
Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers non conducting condition of installed connectors in storage, shipment or during transportation.
sMaterial
Part
Insulator
D
Socket Contact
DA
Pin header contact
Copper alloy
Brass
Material
PBT
Beryllium copper
Connection area
Connection area
Connection area
Connection area
Finish
Black
Gold plated
Gold plated
Gold plated
Tin lead plated
–––––––
–––––––
Remarks
UL94V-0
Selective Gold plated
B15
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sOrdering
Information
qSocket
HIF 3B -
*
D A - 2.54 R
q
w
e
: HIF
: 3B, 3BA, 3BB (50, 60, 64 contacts only)
r
t
y
u
q
Series Name
w
Series No.
e
Number of contacts : 16, 20, 26, 30, 34, 40, 50, 60, 64
r
Contact alignment : D : Double
t
A
: VA type
: 2.54mm
R : ID type
y
Contact pitch
u
Connection type
qPin
Header
HIF 3B -
*
P A - 2.54 DS
q
w
: HIF
:
3BC: (10 contacts only)
3BD: (10 contacts only)
e
r
t
y
u
q
Series Name
w
Series No.
3B
: (14 contacts not included)
3BA, 3BB: (50, 60, 64 contacts only)
r
t
P
A
: Pin header
: Selective gold plated
: 2.54mm
: Right angle type
: Straight type
e
Number of contacts : 16, 20, 26, 30, 34, 40, 50, 60, 64
y
Contact pitch
u
Contact style
DS
DSA
B16
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sSocket
(With guide to prevent mis-insertion)
Body
Protector
Clamp
Note1, Note2: The number of polarizing keys and polarizing keyways changes according to products. Refer to the list as shown below.
Note3: The 50, 60 and 64 contact connector contain two types of polarizing guides. Use the products, referring to Notes 1 and 2.
68.07 60.96 62.23 63.6 One on right and left sides, resp. left sides, resp.
One at center
One at center
One at center
80.77 73.66 74.93 76.3 One on right and left sides, resp.
85.85 78.74 80.01 81.38 One on right and left sides, resp.
The products marked with
5
comply with MIL standard.
B17
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sSocket
with Withdrawal Tab
Unit : mm
Part Number
HIF3BA-10D-2.54R-CL
HIF3BA-16D-2.54R-CL
HIF3BA-20D-2.54R-CL
HIF3BA-26D-2.54R-CL
HIF3BA-30D-2.54R-CL
HIF3BA-34D-2.54R-CL
HIF3BA-40D-2.54R-CL
HIF3BA-50D-2.54R-CL
HIF3BB-50D-2.54R-CL
HIF3BA-60D-2.54R-CL
HIF3BB-60D-2.54R-CL
HIF3BA-64D-2.54R-CL
HIF3BB-64D-2.54R-CL
CL No.
610-0190-4
610-0192-0
610-0193-2
610-0194-5
610-0195-8
610-0196-0
610-0197-3
610-0198-6
610-0201-9
610-0199-9
610-0202-1
610-0200-6
610-0203-4
Number of Contacts
10
16
20
26
30
34
40
50
60
64
A
17.27
24.89
29.97
37.59
42.67
47.75
55.37
68.07
80.77
85.85
B
5.3
12.9
18.0
25.5
30.5
35.8
43.4
56.0
68.5
73.8
B18
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sSocket
Body
Protector
Clamp
Note1: The number of polarizing keys and polarizing keyways changes according to products. For details, refer to the list as shown below.
[i=s]This post was last edited by wo4fisher on 2022-1-22 23:59[/i]**Starting from this post, bsp will be gradually increased and improved according to the resources used.
This section mainly implement...
I plugged the GPS into the computer with a USB cable and installed activesync. The USB port COM3 is available. In VS2005, I created a WinCE 5.0 device application project. I want to make a simple prog...
Please help me:Below is my initialization of ADC, but it doesn't work, and I can't do pin selection yet./****************************************ADC single conversion initialization*******************...
China's new energy vehicles are in a transition period from research and development to real industrial development. In 2012, with the intensive launch of new energy vehicle policy planning, the de...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
From the PIC16F946 datasheet, we know that there are two ways to write values to the LCD for display:
1. Directly write the value to LCDDATA1~LCDDATA23
2. Use disconnect t...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
LED lighting: Basic circuit design can be completed in as little as one day
Semiconductor manufacturers are also getting involved in the LED lighting business. The power circuit of LED req...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
With the rapid development of wireless
digital communication
, more challenges have been raised for integrated circuit design and testing. In the product design stage, in order to ensure
t...[Details]
The launch of Shenzhou IX is imminent, and Tiangong is welcoming visitors again. Yesterday, Professor Fu Qiang, Vice President of the Institute of Science and Industrial Technology of Harbin Instit...[Details]
The ARINC429 bus is one of the most commonly used communication buses between various subsystems of avionics. As the "skeleton" of modern avionics systems, once the bus system or the attached airbo...[Details]