Peizoresistive Sensor, Compound, -14.7Psi Min, 15Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U533A-H00002-015PC Overview

Peizoresistive Sensor, Compound, -14.7Psi Min, 15Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U533A-H00002-015PC Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145065356151
Reach Compliance Codeunknown
Maximum accuracy(%)0.1%
Other featuresPort Height = 13.9 MM
body height66.2 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port type1/4-19 BSPP
Maximum pressure range15 Psi
Minimum pressure range-14.7 Psi
Pressure sensing modeCOMPOUND
Response time2000 µs
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCONNECTOR
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no O-rings or organics exposed to the pressure
media. The U5300 is weatherproof and exceeds the latest heavy industrial
CE requirements including surge protection. The circuit is protected from
reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
07/2018
Page 1
Answer questions to win prizes | ADI Technology Express Issue 1
With the continuous development of electronic technology and new breakthroughs in technologies such as cloud computing, artificial intelligence (AI), the Internet of Things (IoT) and 5G, digital healt...
EEWORLD社区 Sensor
Questions about impedance setting?
[font=微软雅黑, 宋体]Questions about impedance settings? According to the chip manual, the differential signal line needs to set impedance, but when I look at our product wiring, it seems that there is no s...
gurou1 PCB Design
Capacitance and inductance recording
1. The current flowing through a capacitor always leads the voltage by 90°. When we apply voltage to a capacitor, its current reaches its maximum value first and the voltage is 0. As the current decre...
小魏哥哥 Switching Power Supply Study Group
EEWORLD recent recruitment information
Because I just received a call from a netizen who said he was interested in EEWORLD's information about finding people.So here are some recruitment information for your reference:Forum administrator: ...
soso Recruitment
xdata variable problem in keil
Define a global variable int xdata i; Why is the initial value of i not 0?...
好小子 51mcu
(Help) Driver for MPC8315 DMA mode UPM transmission via local bus
Please tell me the way...
dhwdm22 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 135  2745  763  1642  805  3  56  16  34  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号