EEWORLDEEWORLDEEWORLD

Part Number

Search

D2425EGF

Description
Solid State Relay,
CategoryLED optoelectronic/LED    photoelectric   
File Size189KB,5 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Environmental Compliance
Download Datasheet Parametric View All

D2425EGF Overview

Solid State Relay,

D2425EGF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid108373455
Reach Compliance Codecompliant
10-90Amp • 120/240 Vac - AC OUTPUT
Series
1
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 600V Transient Capability
• Internal Snubber
• 110 & 125A Models
Available
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
MODEL NUMBERS
AC CONTROL
DC CONTROL
A1210
D1210
A1225
D1225
A1240
D1240
A2410
D2410
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross, random turn-
on (phase controllable) and normally
closed (Form B) versions with either
AC or DC input (coil) control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
A2425
D2425
A2450
D2450
A2475
D2475
A2490
D2490
OUTPUT SPECIFICATIONS
1
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
24-140
10
40
400
120
1.6
1.48
60
8
500
24-140
25
40
400
250
1.6
1.02
260
8
500
24-140
40
40
400
625
1.6
0.63
1620
8
500
24-280
10
40
600
120
1.6
1.48
60
10
500
24-280
25
40
600
250
1.6
1.02
260
10
500
24-280
50
40
600
625
1.6
0.63
1620
10
500
24-280
75
40
600
1000
1.6
0.31
4150
1
0
500
24-280
90
40
600
1200
1.6
0.28
6000
10
500
3
[Arms]
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
qJC
) [°C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
2
4
0.5
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
1
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
DC CONTROL
3-32 Vdc
-32 Vdc
3.0 Vdc
1.0 Vdc
1500 Ohms
3.4mA @ 5 Vdc, 20mA @ 28Vdc
AC CONTROL
90-280 Vrms (60Hz)
---
90 Vrms
10 Vrms
60K Ohms
2mA @ 120 Vrms, 4mA @ 240 Vrms
24V AC/DC CONTROL
(E SUFFIX)
18-36 Vrms/Vdc
---
18 Vrms/Vdc
4.0 Vrms/Vdc
9.0K Ohms
3mA @ 24 V
GENERAL NOTES
© 2007 CRYDOM Inc., Specifications subject to change without notice.
1
All parameters at 25° C unless otherwise specified.
2
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3
Heat sinking required, for derating curves see page 3.
4
Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
For recommended applications and more information contact:
USA:
Sales Support (877) 502-5500
Tech Support
(877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 606030 •
FAX
+44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
SERIES1
Rev. 100107
PAGE 1 OF 4
Control
[i=s]This post was last edited by paulhyde on 2014-9-15 09:43[/i] Smart Car...
hzxbmw Electronics Design Contest
Analysis of optimization methods for overcrowded solder joints in PCB design
Analysis of optimization methods for overcrowded solder joints in PCB designIf the solder joints in PCB design are too dense, it is easy to cause wave soldering and leakage between solder joints. The ...
ohahaha PCB Design
Have you passed all the exams?
The final exams for forum friends are almost over! Did everyone pass?...
maylove Talking
I don't know where the error is. Please help me.
My CCs is set up, but when I save and start it, Error adding memory map range: End address is beyond target memory length appears. Can anyone help me? Thank you....
zhaohongpeng DSP and ARM Processors
A Brief Analysis of the Control Function of Configuration Software
Currently, configuration software has been widely used in industrial control. Configuration software connects to various hardware devices based on its own process database, and can display the collect...
jek9528 Industrial Control Electronics
Previous Good Books Comic Books Electronic Circuits
You can learn by reading comics[[i] This post was last edited by ddllxxrr on 2011-4-8 17:43 [/i]]...
ddllxxrr Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1625  165  2892  2575  1078  33  4  59  52  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号