EEWORLDEEWORLDEEWORLD

Part Number

Search

T212D187K010DS7443

Description
Tantalum Capacitor, Polarized, Tantalum (dry/solid), 10V, 10% +Tol, 10% -Tol, 180uF,
CategoryPassive components    capacitor   
File Size2MB,26 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

T212D187K010DS7443 Overview

Tantalum Capacitor, Polarized, Tantalum (dry/solid), 10V, 10% +Tol, 10% -Tol, 180uF,

T212D187K010DS7443 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid7009217806
package instruction,
Reach Compliance Codenot_compliant
ECCN codeEAR99
capacitance180 µF
Capacitor typeTANTALUM CAPACITOR
diameter8.92 mm
dielectric materialsTANTALUM (DRY/SOLID)
JESD-609 codee0
leakage current0.009 mA
length19.96 mm
Installation featuresTHROUGH HOLE MOUNT
negative tolerance10%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formAxial
method of packingAMMO PACK
polarityPOLARIZED
positive tolerance10%
Rated (DC) voltage (URdc)10 V
surface mountNO
Delta tangent0.06
Terminal surfaceTin/Lead (Sn60Pb40)
Terminal shapeWIRE
Tantalum Through-Hole Capacitors – Hermetically Sealed
T110 Axial MIL–PRF–39003 Polar Type and
T212 (CSR13 Style)
Overview
The KEMET standard hermetically sealed T110 Series is
targeted for use in high humidity environments. These
capacitors are ruggedly built, designed for miniaturized
circuitry, and are especially well-suited for coupling, bypass,
filtering and RC timing circuits. The T110 Series exhibits
excellent stability as well as extremely low DC leakage
current, dissipation factor, and ESR/impedance over a wide
temperature and frequency range. Available in standard
EIA capacitance values from 0.0047 µF to 330 µF in ±20%,
±10%, and ±5% tolerances, the T110 Series is now offered in
working voltages of 6 VDC to 125 VDC and low ESR limits.
Higher CV values in comparable case sizes are available in
the KEMET T410 Series.
Benefits
• Taped and reeled per EIA Specification RS–296
• Marking per MIL–STD–1285
• Qualified to MIL–PRF–39003 (CSR13 Style)
• Failure rate options: Graded – B, C, D, and G
Exponential – M, P, R, and S*
• Capacitance values of 0.0047 μF to 330 μF
• Tolerances of ±5%, ±10% and ±20%
• Voltage rating of 6 – 125 VDC
• Operating temperature range of −55°C to +125°C
• Case sizes: A, B, C, D
*Failure rates apply to military products only
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
Applications
Typical applications include coupling, bypass, filtering and RC timing circuits in miniaturized circuitry.
One world. One KEMET
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
T2031_T110_AXIAL_T212 • 2/24/2020
1
Help with LwIP operating system transplantation, compilation and linking issues!
There is no problem in compiling, but there are several problems in linking as follows: .\Object\ucos_lwip.axf: Error: L6406E: No space in execution regions with .ANY selector matching rit128x96x4.o(....
186874509 Microcontroller MCU
Factors affecting the characteristic impedance of printed circuit boards (PCBs) and their countermeasures
Factors affecting the characteristic impedance of printed circuit boards (PCBs) and their countermeasures...
fighting PCB Design
"Play with pyboardCN V2" 1 Install the driver and serial port assistant to light up 4 lights
[i=s]This post was last edited by damiaa on 2018-6-25 09:18[/i] "Play with pyboardCN V2" Part 1 Install the driver and serial port assistant to light up the four lights 1. Install PUTTY or Tera Term V...
damiaa MicroPython Open Source section
Regarding the problem of hmc5883L, there has been a problem with data reading and writing. Please take a look
Regarding HMC5883L, I used MSP to implement it, but the data is always wrong and the range of change is always around 180~250. I don't know what the problem is....
aaronjedi 51mcu
Error when installing RHEL5
When I install RHEL5 on vmware, the following error message appears. My operating system is win7, what is the reason? ? Thank you[[i] This post was last edited by Pumpkin from Jianghan University on 2...
江汉大学南瓜 Linux and Android
Register reading and writing problems in xps
During the creation of the XPS project, I selected DDR2 as the data , instruction, and stack space . I added my own user-defined IP. This IP has several registers that can be read and written by softw...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1494  2546  324  2854  1974  31  52  7  58  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号