EEWORLDEEWORLDEEWORLD

Part Number

Search

2639LP/2A23608L380V/6

Description
Rocker Switch, SPDT, Latched, 10A, 12VDC, Solder/quick Connect Terminal, Concave Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size229KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2639LP/2A23608L380V/6 Overview

Rocker Switch, SPDT, Latched, 10A, 12VDC, Solder/quick Connect Terminal, Concave Rocker Actuator, Panel Mount

2639LP/2A23608L380V/6 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeCONCAVE ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature125 °C
Minimum operating temperature-20 °C
method of packingBULK
sealDUST PROOF; WATER PROOF
surface mountNO
Switch actionLATCHED
switch functionSPDT
Switch typeROCKER SWITCH
Termination typeSOLDER/QUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
D78F9177.pdf
D78F9177.pdf...
Rick37 Power technology
Is the data cable of 432lanuchpad dedicated?
I want to ask, is the data cable of 432lanuchpad special? My data cable was taken away by someone in the company, and I can't download with other data cables, so angry!...
Ds_Sky Microcontroller MCU
Fighting for the title of the best university - WCG2010 AMD Cup Campus Battle ignites the flames of war in May
[font=宋体]“[/font][font=Calibri]WCG2010 AMD[/font][font=宋体]Campus Championship” is an e-sports event specially designed for college students by the world-renowned chip manufacturer [/font][font=Calibri...
AMD_XD Talking
How do you transfer your phone contacts when you change your phone?
In the previous post about DIY mobile phones, I mentioned the issue of importing mobile phone contacts. It seems that there is no unified standard for the contacts of different brands of mobile phones...
wangfuchong Talking
Newbie help, description of vhdl state machine
I have just started learning vhdl, and have seen many examples of writing state machines, but they are all the classic two-stage style. However, I heard that the best way to describe a state machine i...
ruoxie FPGA/CPLD
About the use of dac0832
I want to use dac0832 to output several voltages, even 4 voltages. But I used the direct-through method to design the circuit, which is to connect wr2, xfer, ground terminal, and output current termin...
liufengjing9 PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 136  2839  2855  2328  839  3  58  47  17  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号