EEWORLDEEWORLDEEWORLD

Part Number

Search

56.42.8.024.00541

Description
Electromechanical Relay, DPDT, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.42.8.024.00541 Overview

Electromechanical Relay, DPDT, AC/DC Output

56.42.8.024.00541 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width20.7 mm
body height36.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)19.2 V
Coil resistance190 Ω
Maximum coil voltage (AC)26.4 V
Nominal coil voltage24 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts4000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Nickel
Number of terminals8
operating hours8 ms
PCB hole count8
physical size27.7mm x 20.7mm x 36.8mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay functionDPDT
release time3 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
GMS87C1102-GMS87C1202.pdf
GMS87C1102-GMS87C1202 is mainly used in mobile phones...
rain PCB Design
Why doesn't ST make a software similar to DAVE?
Since ST has gone to great lengths to create a library, why not learn from Infineon and create a software similar to DAVE? This way, it would be much easier to initialize the system! When I first came...
gskinggs stm32/stm8
A complete guide to FPGA development for electronic engineers
The Essential Guide for Electronic Engineers to Innovative Design: A Complete Guide to FPGA Development (Part 1) 114 pages...
douglas816 FPGA/CPLD
The first hello, world program compiles without errors, but when executed it prompts: Connection was not created
The emulator can be opened, and then a message pops up saying Connection was not created. It is not a problem with the emulator settings. I have already selected Win32 [WCE emulator] and the standard ...
ricky03221115 Embedded System
When opening the ad software, an error message appears
After opening the ad, it shows unrecognized project file version[img]C:\Users\Administrator\Desktop[/img]...
jeremy是新手 PCB Design
Have you been using KEIL3 for a long time but still can’t build a project?
Hello everyone, I am using KEIL-MLK3.4 version. I have been unable to build a project for a long time. I am a novice and need help!...
cuizhihao Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1137  1478  1500  1867  1364  23  30  31  38  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号