EEWORLDEEWORLDEEWORLD

Part Number

Search

177-740-5-51-2GP6K1-18MNN

Description
Cable Assembly, 26AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-740-5-51-2GP6K1-18MNN Overview

Cable Assembly, 26AWG,

177-740-5-51-2GP6K1-18MNN Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7005106266
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL8.23
Other featuresSTANDARDS: MIL-DTL-83513, MIL-W-22759/11
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1PIN CONNECTOR
ConnectorSide2PIN CONNECTOR
Connector bracket typeCABLE ASSEMBLY
insulator materialEXTRUDED TFE TEFLON
length0.42 mm
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
shieldNO
Wire gauge26 AWG
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
Can't configure the Linux kernel of mini2440? ?
Please help me find out how to solve this problem....
wuquan-1230 Linux and Android
Causes of PCB line noise
[align=left]When electromagnetic interference is found in digital circuits, the main reason is that on the power line and ground line, obvious noise voltage can be observed with an oscilloscope. Altho...
jdbzhl Energy Infrastructure?
Puran Communications (Shanghai) is looking for a senior software engineer
-------------------------------------------------------------------------------- Puran Communication Technology (Shanghai) Co., Ltd. ([url=http://www.opulan.com]http://www.opulan.com[/url]) is a high-...
youyouyouxia Embedded System
Discussion of CCM buck circuit
After reading Raymond B. Ridley's paper, I designed a 10V-5V circuit based on the Simplis simulation tool. However, there are still many things that are not very clear. I found that the basis for meas...
海南的苹果 Power technology
Make announces its return
[i=s]This post was last edited by dcexpert on 2019-8-20 23:44[/i]A few months ago, Make announced that it would cease publication due to financial problems. A few days ago, Make announced its return.A...
dcexpert MicroPython Open Source section
If you have any unused electronic items, come and exchange them!
This section has added some new categories for everyone to interact with:Gift: Many friends have some unused boards and items that can be given to friends in the forum; Exchange: to hope to exchange o...
soso Buy&Sell

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 532  1761  825  2905  284  11  36  17  59  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号