EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS100AF/J

Description
AC-DC Power Factor Correction Module,
CategoryPower/power management    The power supply circuit   
File Size589KB,4 Pages
ManufacturerTDK-LAMBDA
Download Datasheet Parametric View All

ZWS100AF/J Overview

AC-DC Power Factor Correction Module,

ZWS100AF/J Parametric

Parameter NameAttribute value
MakerTDK-LAMBDA
package instruction,
Reach Compliance Codecompliant
Is SamacsysN
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Base Number Matches1
• Universal Input (85 - 265VAC)
• Power factor Corrected
• Input transient Corrected
• Peak Power capability
• 2 year warranty
• High quality design
Key Market Segments & Applications
Factory Automation
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
Gaming, Vending, Printers
ZWS-AF Series
50 - 150W
Single output power supplies
ZWS-AF Features and Benefits
Features
• Input Transient Protected
• 2 Year Warranty
• Power Factor Corrected
• Peak Power Capability
Test & Measurement
Light Industrial
Benefits
• Withstands Harsh Environments
• Low Cost of Ownership
• Supports Global Use
• Can Drive High current Start Up Devices
Specifications
MODELS
ITEMS
AC Input Voltage range
DC Input Voltage range
Input Current (Typ)
Inrush Current
Power Factor
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection
Hold Up Time (Typ)
Leakage Current
Remote On / Off
Operating Temperature
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock (in packaging)
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
Notes:
(1) 100/200VAC (2) ZWS150AF -10 to 60°C, Derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
ZWS50AF
ZWS75AF
ZWS100AF
ZWS150AF
(1)
(1)
(4)
(1)
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3V & 5V :120mV, 12V to 24V : 150mV, 36V & 48V : 200mV
<0.02%/°C
>105% of Peak Current Capability
20
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, Derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Gnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Gnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL/CSA60950-1, EN60950-1, EN50178, CE Mark
Designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
Designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
2 Years
ZWS-AF Series
1

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1643  207  2239  1296  2658  34  5  46  27  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号