EEWORLDEEWORLDEEWORLD

Part Number

Search

059-0113

Description
Electric Fuse, 7A, 440VAC, Inline/holder
CategoryCircuit protection    Circuit protection   
File Size58KB,1 Pages
ManufacturerCooper Industries
Environmental Compliance
Download Datasheet Parametric View All

059-0113 Online Shopping

Suppliers Part Number Price MOQ In stock  
059-0113 - - View Buy Now

059-0113 Overview

Electric Fuse, 7A, 440VAC, Inline/holder

059-0113 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCooper Industries
Reach Compliance Codecompliant
Is SamacsysN
body height32.05 mm
Body length or diameter6.37 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal84 J
Manufacturer's serial number059
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.37mm x 32.05mm
Rated current7 A
Rated voltage (AC)440 V
GuidelineBS
surface mountNO
Terminal shapeEND CAP
Base Number Matches1
BS88
Joint Service Fuse Links
Ferrule type fuses 0.25 to 15 Amp 440V ac
Body Size '0'
Time-Current Characteristic Curves
Bussmann
®
2A
3A
5A
7A
10A
15A
The range of Joint Service Fuse Links was originally
developted for the Admiralty, but is now classified under
the N.A.T.O. Reference system, Ref. Number 5920.99
The fuse links have been type approved and include short
circuit tests to BS88, at 440 volts 33kA.
The complete Joint Service range has been entered by
Lloyd's Register of Shipping in their schedule 'A' cartridge
fuses for use in all types of ships.
Whilst intended for use by the Services, the fuse links are
also suitable for normal industrial applications, being
especially useful wherever space is at a premium, e.g. In
the electronic, aeronautical and allied industries.
Dimensional Data (mm)
32.05
5.55
5.55
Fuse Type
and
Catalogue
Number
059-0107
059-0108
059-0109
059-0110
059-0111
059-0112
059-0113
011-9925
011-9926
I
2
t (Amp
2
Seconds)
Rating Amps
Pre-Arcing
0.169
0.939
1.66
5.26
20.2
49.3
84.1
135
539
Total at 440V
0.337
1.88
3.33
10.5
40.4
148
252
404
1,620
Nom. Watts
Loss
2.65
1.11
1.7
3.15
2.88
2.02
2.42
3.7
4.71
Packaging - 100 per carton standard,
also available 10 to a pack - add 10
as a suffix to the reference number.
0.25
0.5
1
2
3
5
7
10
15
This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update,
without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by
the user in all possible applications.
Bussmann Division
Cooper (U.K.) Ltd
Burton-on-the-Wolds
Leicestershire, LE12 5TH
United Kingdom
Tel: (44) (0)1509 88 27 37
Fax: (44) (0)1509 88 27 86
Head Office
St. Louis, MO, U.S.A. Tel: (314) 527-3877 Fax: (800) 544-2570 International Fax: (314) 527-1445
B
i
F
Bussmann Information Fax (00 1) 314 527 1450
Joint Service 11.96
Doc. No. 4188
6.37
0.25A
0.5A
1A
Newbie help with LPC1765 low power mode code
I want to turn off the PLL or enter deep sleep mode. The code stops running at while ((LPC_SC->PLL0STAT & (1<<25)) != 0x00);. Why is this? Or is there any low power engineering code? :)...
xiaovhl MCU
Sharing of experience in single board circuit design (1) - power supply filtering
[align=left][color=rgb(34, 34, 34)][font=宋体][size=4]There are some common experiences in single board design, and I will share them with you today. [/size][/font][/color][/align][align=left][color=rgb...
tiankai001 Analog electronics
Application of industrial control computers in coal mine safety production system monitoring
The energy industry is the lifeblood of our country's economic development. In recent years, with the shortage of oil resources and the soaring oil prices, the importance and irreplaceability of the c...
vini Industrial Control Electronics
“Taming” Oscillations—The Capacitive Load Problem
[size=4][size=3][font=宋体][color=#333333]I found several good articles in the [b]TI E2E[/b] community, and I translated them to share with you. Among them, the [color=#000000]Bruce Trump series has goo...
德州仪器 Analogue and Mixed Signal
Powerful program editor SourceInsight-v3.50.0050
Powerful Program Editor SourceInsight-v3.50.0050 Source Insight is a powerful program editor with built-in parsing of C/C++, Java and x86 assembly language programs; it has its own dynamic database to...
MCU—杨博 Embedded System
CCS cannot burn the program
[b]What is the reason for "cannot load from non-primitive location" during CCS debugging? [/b]...
mw102378 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 251  669  121  152  534  6  14  3  4  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号