JBX
Push Pull
Pull
JBX Push Pull
High reliability where quick, simple coupling mechanism is required
Secure, quick confirmed mating
Blind mate capability
A versatile product
✓
✓
✓
✓
✓
✓
Tactile, Audible, Visual
Mechanically keyed - prevents accidental
engagement of wrong connector
* Ergonomic design, fast and easy to use
* Modular design
* 5 shell sizes
*
Solder, crimp, PCB, R/A PCB contact terminations
* Small footprint, allows access in tight
applications
* High density layouts 2 - 30 pins
Multiple cable collets / single part number
Metal shielding housing, high vibration and
shock environments
Space Saving
www.souriau.com
Economical
Rugged
Push Pull Connectors
Part number system
Basic series
Shell type-Receptacle
Shell type - Plug
Shell size
Keying
Contact layout
Contact type
Contact termination
Surface plating
Obligatory Suffix
Contact Size
Cable Backnut Option
Key Identifier
FD-FC-FF-FM-FN
00 - 0 - 1 - 2 - 3
G-J-A-B
02 ---------- 30
M
: pin
F
: socket
Solder
Crimp
PCB Straight Tails*
PCB Right Angle*
Contact Diameter mm
Male Insulator Wire Side
Push Pull Connectors
Contacts layouts
JBX
ER-EA-SR-PC-ED-EP-EZ-SA
FD
1
G
05
M
C
S
D
S
M
R
Shell size 2
02
03
04
05
06
07
08
S
C
XX
S
C
XX
S
C
P
Q
S
C
P
Q
1.3
S
C
P
Q
1.3
S
C
P
Q
1.3
S
C
P
Q
0.9
C:
crimp;
S:
solder;
P*:
straight PCB tails ;
Q*:
Right Angle PCB tails
S
: Outer shell brass alloy chrome over nickel plating
N
: Outer shell in brass alloy with black plating (consult Souriau USA)
D
: For all part numbers
S
: All contact diameters except .05 mm
P
: 0.5 mm contact dimensions only
M
: Connector with backnut for protective boot - Protective boot to order separately page 13
R :
Red dot on shell for ED, ER, EZ, PC, SR, FC, FD, FF, FM & FN only
1.3
1.3
1.3
Shell size 2
Male Insulator Wire Side
*
For receptacles with female contacts only.
10
12
16
18
19
Shell Types
Technical characteristics
Environmental
Solder
Crimp
PCB Straight Tails*
PCB Right Angle*
Contact Diameter mm
S
C
P
Q
0.9
S**
C
P
Q
0.7
S**
C
P
Q
0.7
0.7
0.7
S**
C
P
S**
C
P
*
*
*
*
IP40 & IP 67/68
Temperature range: IP40 -40
°
- +125
°
C
Temperature range: IP67/68 -40
°
- +80
°
C
Shielding effectivity: 55dB up to 100MHg
ER :
Front panel mount, fixed receptacle front flange
FD :
Straight plug
EA :
Front or rear panel mount with double nuts
fixed receptacle
Mechanical
*
*
*
*
*
*
*
*
*
Shell: Brass alloy
Shell plating: Chrome over nickel
Insulator: Peek
Contact: Brass
Contact plating: Gold
Up to 8 key options
7 Color code options
5 Shell sizes
>1,000 Mating cycles
EP :
fixed receptacle, back panel mounting, fixed rear
panel flange (appropriate with 90° contacts for PCB)
Shell size 3
03
Male Insulator Wire Side
FC :
Right angle plug
ED :
Front mount protruding shell panel mount
receptacle
04
07
08
10
14
18
22
30
FN :
Straight plug with lanyard
SR :
Front panel mount cable receptacle. fixed
front flange
Electrical
* Contact temination: Solder, Crimp
PCB, R/A PCB
* Contact rating:
0.5mm 2.0-2.5 Amp
0.7mm 5.0-7.0 Amp
0.9mm 7.0-10.0 Amp
1.3mm 11.0-15.0 Amp
1.6mm 15.0-17.0 Amp
2.0mm 25.0-30.0 Amp
Solder
Crimp
PCB Straight Tails*
PCB Right Angle*
Contact Diameter mm
S**
C
XX
S**
C
XX
S
C
XX
S
C
P
S
C
P
S
C
P
S
C
P
S**
C
P
S**
C
P
PC :
Inline cable receptacle
FM :
Right angle plug with lanyard
EZ :
PCB straight receptacle
FF :
Straight plug, no latch
2
2
1.6
1.3
1.3
0.9
0.9
0.7
0.7
Please contact Souriau for additional technical information
SA :
Front or rear mount cable receptacle with
double nuts, panel mount
Push Pull Connectors
Contacts layouts
Shell size 00
04
Male Insulator Wire Side
Solder
Crimp
PCB Straight Tails
PCB Right Angle*
Contact Diameter mm
0.5
S
Push Pull Connectors
KEYING
J
Key
G
sizes 0 - 1
Keying angle
Plug
0°
45°
Dual Key Way
• Voltage Test Procedure
-
The testing voltage
corresponds to the maximum voltage the connector is able to withstand
in normal climatic conditions. The value is about 75% of the electrical breakdown voltage. The
testing voltage level can be reached several times in connectors life, but never applied for a con-
tinuous duration.
-
The working voltage
corresponds to the maximum voltage the connector is able to withstand
continuously during its life time, in real environmental conditions, even with high temperature.
The value is around 1/3 of the testing voltage
.
A
sizes 2 - 3
37.5°
30°
B*
60°
• Maximum current rating
-
This indicated maximum current rating
corresponds to the maximum current that can be ap-
plied
simultaneously on each line of the connector mated pair,
continuously during its life
time, in normal climatic conditions.
Remark : If the current is applied on only one contact of the layout, then an increased current
value can be achieved over a long duration.
Receptacle
Options
• Protective boot
With each JBX connector, one protective
boot can accept diverse cable diameters
thus the end-user can manage various
cable diameters without bothering with
multiple part numbers.
Part
number
JBX 00 MPN
JBX 0 MP*
JBX 1 MP*
JBX 2 MP*
JBX 3 MP*
Shell
size
00
0
1
2
3
Dimensions
Ø
A
1.5
2.2
2.6
4
5
L
min
15
20
25
30
35
1
1.5
2
3.5
4.9
Ø
Cable
max
3.5
5.5
7.5
9.7
12
Shell size 0
02
Male Insulator Wire Side
03
04
05
06
07
08
Solder
Crimp
PCB Straight Tails*
PCB Right Angle*
Contact Diameter mm
S
C
P
Q
0.9
S
C
P
Q
0.9
S**
C
P
Q
0.7
S**
C
P
Q
0.7
S**
S**
S**
P
P
P
* Color code - See chart below / In size 00, available only in black
Color code
0.5
0.5
0.5
Colors
blue
white
grey
yellow
brown
black
red
green
orange
Material :
ELASTOLLAN (PUR)
Working temperature :
- 40°C ; + 80°C
- 40°F ; + 176°F
A
B
G
J
M
N
R
V
O
Shell size 1
Male Insulator Wire Side
02
03
04
05
06
07
08
10
12
Parts that require a protective boot
need to be ordered with an M
suffix.
Protective boots are ordered
separately.
Solder
Crimp
PCB Straight Tails*
PCB Right Angle*
Contact Diameter mm
S
C
P
S
C
P
Q
S
C
P
Q
0.9
S
C
P
Q
0.9
S**
C
P
Q
0.7
S**
C
P
Q
0.7
S**
C
P
Q
0.7
S**
S**
• Caps :
an efficient protection
against dust
P
P
Receptacle Caps
Part number
Shell
Size
Plug Caps
Part number
JBX BF00
Shell
Size
00
0
1
2
3
1.3
1.3
0.5
0.5
JBX BR0
JBX BR1
0
1
2
3
JBX BF0
JBX BF1
JBX BF2
JBX BF3
**Inserts
with fixed non removable contacts
*
For receptacles with female contacts.
Note :
Contact numbering mating faces receptacle view: counterclockwise from key at position 1
Contact numbering mating faces plug view: clockwise from key at position 1
JBX BR2
JBX BR3
Push Pull Connectors
Dimensions - Receptacles
ER :
Front mount
EA :
Double nut
EP :
Rear mount
Push Pull Connectors
Dimensions - Plugs
FC :
Straight Plug with Lanyard
FM :
Right angle with lanyard
FF :
Straight, no latch
Size
A
B
C
Ø
D
00
14
6
0.8
8
0
19
8
1.2
10
1
21
10
1.5
14
2
24
10
1.8
18
3
28
12
2.0
22
Size
A
B
C
Ø
D
0
19
6.7
2.5
12
1
21
8.3
3.2
16
2
24
8
3.8
20
3
28
9.5
4.5
24
Size
A
B
C
Ø
D
0
19
4.5
2.5
12
1
21
6
3.2
16
2
24
6.5
3.8
20
Size
A
B
C
Ø
D
0
30.5
20.5
29.5
10
1
36.5
25.5
33.5
12
2
42.5
30.5
36.5
15
3
50.5
35.5
45
18
Size
A
B
C
Ø
D
0
30.5
20.5
29.5
10
1
36.5
25.5
33.5
12
2
42.5
30.5
36.5
15
3
50.5
35.5
45
18
Size
A
B
C
Ø
D
0
30.5
20.5
29.5
10
1
36.5
25.5
33.5
12
2
42.5
30.5
36.5
15
3
50.5
35.5
45
18
SA :
Double nut panel
mount receptacle
ED :
Front mount, protruding
SR :
Front mount cable clamp
FN :
Straight plug with lanyard
FC :
Right angle
FD :
Straight
Size
A
B
C
Ø
D
0
38
-
2.5
12
1
43
-
3.2
16
2
50
6.5
3.8
20
3
59
-
-
24
Size
A
B
C
Ø
D
0
19
3
1.2
10
1
21
4.5
1.5
14
2
24
6.3
1.8
18
Size
A
B
C
Ø
D
0
38
8
1.2
10
1
43
10
1.5
14
2
50
10
1.8
18
3
59
12
2
22
Size
A
B
Ø
C
00
31
23
8
0
39
29
1
1
45
34
13
2
52
40
16
3
62
47
19
Size
A
B
C
Ø
D
0
30.5
20.5
29.5
10
1
36.5
25.5
33.5
12
2
42.5
30.5
36.5
15
3
50.5
35.5
45
18
A
B
Ø
C
31
23
7
39
29
10
45
34
12
52
40
15
62
47
18
Size
00
0
1
2
3
PC :
In line receptacle
EZ :
PCB
Range of cable diameters
With the plastic collet set supplied with the standard product, a wide range of cable diameters is allowed. Find below the max-
imum and the minimum for each size of shell (for information only because it can change with the cable characteristics).
Size
Size
Ø
A
B
C
D
Ø
E
0
10
19
4
7.62
1.1
1
12
21
4
7.62
1.1
Ø A min
Ø A Max
00
1.1
3.5
0
1.5
5.5
1
2.0
7.5
2
3.5
9.7
3
4.9
12.0
Size
A
Ø
B
0
38
10
1
43
13
2
50
16
3
59
19.5