EEWORLDEEWORLDEEWORLD

Part Number

Search

3GDF62GE-80T-60.000

Description
LVDS Output Clock Oscillator, 60MHz Nom, ROHS COMPLIANT, SMD, 6 PIN
CategoryPassive components    oscillator   
File Size156KB,1 Pages
ManufacturerEuroquartz
Websitehttp://www.euroquartz.co.uk/
Environmental Compliance
Download Datasheet Parametric View All

3GDF62GE-80T-60.000 Overview

LVDS Output Clock Oscillator, 60MHz Nom, ROHS COMPLIANT, SMD, 6 PIN

3GDF62GE-80T-60.000 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresTRI-STATE; ENABLE/DISABLE FUNCTION
Maximum control voltage3 V
Minimum control voltage0.3 V
maximum descent time0.7 ns
Frequency Adjustment - MechanicalNO
Frequency offset/pull rate80 ppm
frequency stability50%
Installation featuresSURFACE MOUNT
Nominal operating frequency60 MHz
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Oscillator typeLVDS
Output load50 OHM
physical size11.4mm x 9.6mm x 2.5mm
longest rise time0.7 ns
Maximum supply voltage3.465 V
Minimum supply voltage3.135 V
Nominal supply voltage3.3 V
surface mountYES
maximum symmetry55/45 %
Base Number Matches1
EURO
QUARTZ
11.4 x 9.6 x 2.5mm SMD
Frequency range 38MHz to 640MHz
LVDS Output
Supply Voltage 3.3 VDC
Phase jitter 0.4ps typical
Pull range from ±30ppm to ±150ppm
GDF62 LVDS VCXO
38.0MHz to 640.0MHz
DESCRIPTION
GDF62 VCXOs are packaged in a 6 pad 11.4 x 9.6m SMD package.
Typical phase jitter for GDF series VCXOs is 0.4 ps. Output is LVDS.
Applications include phase lock loop, SONET/ATM, set-top boxes,
MPEG , audio/video modulation, video game consoles and HDTV.
OUTLINE & DIMENSIONS
SPECIFICATION
Frequency Range:
Supply Voltage:
Output Logic:
RMS Period Jitter:
Peak to Peak Jitter:
Phase Jitter:
Initial Frequency Accuracy:
Output Voltage HIGH (1):
Output Voltage LOW (0):
Pulling Range:
Control Voltage Range:
Temperature Stability:
Output Load:
Rise/Fall Times:
Duty Cycle:
Start-up Time:
Current Consumption:
Static Discharge Protection:
Storage Temperature:
Ageing:
Enable/Disable:
RoHS Status:
38.0MHz to 640.0MHz
3.3 VDC ±5%
LVDS
3.0ps typical
20.0ps typical, 30.0ps maximum
0.4ps typical, 5.0ps maximum
Tune to the nominal frequency
with Vc= 1.65 ±0.2VDC
1.4 Volts typical
1.1 Volts typical
From ±30ppm to ±150ppm
1.65 ±1.35 Volts
See table
50W into Vdd or Thevenin equiv.
0.5ns typ., 0.7ns max.
20% Vdd to 80% Vdd
50% ±5%
(Measured at Vdd-1.3V)
10ms maximum, 5ms typical
55mA typical, 60mA maximum
(At 202.50MHz)
2kV maximum
-55° to +150°C
±2ppm per year maximum
See table
Fully compliant or non compliant
FREQUENCY STABILITY
Stability Code Stability ±ppm Temp. Range
A
25
0°~+70°C
B
50
0°~+70°C
C
100
0°~+70°C
D
25
-40°~+85°C
E
50
-40°~+85°C
F
100
-40°~+85°C
If non-standard frequency stability is required
Use ‘I’ followed by stability, i.e. I20 for ±20ppm
ENABLE/DISABLE FUNCTION
Tristate Pad
Status
Not connected
Below 0.3Vdd
(Ref. to ground)
Above 0.7Vdd
(Ref. to ground)
Output Status
LVDS and Complimentary LVDS enabled
Both outputs are disabled (high impedance)
Both outputs are enabled
PART NUMBERING
Example:
Supply Voltage
3 = +3.3V
Series Designator
GDF62
RoHS Status
G = Compliant
Blank - Non-compliant
Stability over temperature range
(See table)
Pullability in ±ppm
Pullability determinator
N = minimum
M = maximum
T = Typical
Frequency in MHz
3GDF62GB-80N-60.000
EUROQUARTZ LIMITED Blacknell Lane CREWKERNE Somerset UK TA18 7HE
Tel: +44 (0)1460 230000 Fax: +44 (0)1460 230001 info@euroquartz.co.uk www.euroquartz.co.uk
Issues with identifiers in AD09
Please help, why after modifying the identifier, there is a lighter color and bracketed original identifier next to the identifier, what is going on?...
哼啊啊啊啊 PCB Design
How to program several digital tubes to light up at the same time?
At first, I saw a code using P0=0xea, and later I saw a code using P2=2, P0=0x3f (this is for the stc microcontroller I just bought, but I don’t know how to light up multiple digital tubes at the same...
hulala Embedded System
Help me figure out what's going on
When I connect keil3 to the development board and click debug, the message "Conception to target system lost" appears, but I can hear the sound of the relay on the development board. I have been worki...
gampt 51mcu
Urgent~~~~Get hard disk information under DOS
I would like to ask, in DOS system, when SATA hard disk is in AHCI mode, how to programmatically obtain hard disk information, such as hard disk model name, etc.?...
diyichen Embedded System
The evolution history of the world's famous car brand logos - Cadillac
[b]Cadillac[/b][b] Cadillac[/b] The birth of the Cadillac brand under General Motors is actually related to Henry Ford, the founder of Ford Motor Company. Didn’t you expect it? The story starts before...
1ying Automotive Electronics
AVR interrupt problem???????? . . .
I have a small program here. When debugging, as long as the global interrupt is turned on (hint: the serial port interrupt was turned on before), the print information will not be printed completely, ...
xmmant Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 136  1008  2865  1757  1960  3  21  58  36  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号