D38999/26KD15SD

Description
MIL Series Connector, 15 Contact(s), Stainless Steel, Female, Crimp Terminal, Plug,
CategoryThe connector    The connector   
File Size192KB,1 Pages
ManufacturerAero-Electric Connector
Websitehttps://www.aero-electric.com/index.html
Download Datasheet Parametric View All

D38999/26KD15SD Overview

MIL Series Connector, 15 Contact(s), Stainless Steel, Female, Crimp Terminal, Plug,

D38999/26KD15SD Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerAero-Electric Connector
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARD: MIL-DTL-38999, EMI/RFI SHIELDED, POLARIZED, COMPATIBLE CONTACTS: M39029/56-352; M39029/56-353
Back shell typeSOLID
Body/casing typePLUG
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Number of contacts\"14,1\"
Contact size\"20,16\"
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsCORROSION/ENVIRONMENT/FLUID/VIBRATION RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
Maximum operating temperature200 °C
Minimum operating temperature-65 °C
OptionsGENERAL PURPOSE
polarizationD
Shell materialSTEEL
Housing sizeD
Termination typeSOLDER
Total number of contacts15
Unique insertion numberD15
D38999/26
Self-Locking, RFI Grounding Plug
AE326
Triple Start Threaded Coupling, Crimp Removable, Rear Release, Scoop-Proof
31.00(1.220)
MAX
BLUE COLOR BAND
LOCATION OPTIONAL
(REAR RELEASE)
A
MASTER KEY
MAX
COUPLING NUT
2.16(.085) MAX
GROMMET EXTENSION
7.11(.280)
MIN FULL THREAD
B
MAX
GROMMET
MIL–DTL–
38999 S III
RFI STRIP
T
NUMBER OF TEETH
D
ACCESSORY THREAD
E
4 MINOR KEYS
MATING THREAD
Page 38
Page 44
Pages 17–19
Page 37
Pages 15, 16
Page 42
Completed Part Number
Contacts, Sealing Plugs and Tools
Insert Arrangements
Performance Specifications
Insert Availability and Contact Information
Polarization
Note :
Maximum Grommet Extension for insert layouts
incorporating size 8 and 10 contacts =
5.95(.234).
A
Shell
Size
A
B
C
D
E
F
G
H
J
Maximum
inch
.858
.984
1.157
1.280
1.406
1.516
1.642
1.768
1.890
mm
21.80
25.00
29.40
32.50
35.70
38.50
41.70
44.90
48.00
inch
.299
.427
.541
.666
.791
.897
1.022
1.147
1.272
B
Maximum
mm
7.59
10.85
13.74
16.92
20.09
22.78
25.96
29.13
32.31
D
Accessory Thread
Metric
M12x1.0-6g 0.100R
M15x1.0-6g 0.100R
M18x1.0-6g 0.100R
M22x1.0-6g 0.100R
M25x1.0-6g 0.100R
M28x1.0-6g 0.100R
M31x1.0-6g 0.100R
M34x1.0-6g 0.100R
M37x1.0-6g 0.100R
E
Mating Thread
Class 2B
.6250-0.1P-0.3L
.7500-0.1P-0.3L
.8750-0.1P-0.3L
1.0000-0.1P-0.3L
1.1875-0.1P-0.3L
1.2500-0.1P-0.3L
1.3750-0.1P-0.3L
1.5000-0.1P-0.3L
1.6250-0.1P-0.3L
T
No. of
Teeth
12
16
20
24
28
32
36
40
44
www.conesys.com
– 41 –
sales
@
aero-electric.com
About RAM and ROM self-test functions written by MC9S12GMLL chip
When debugging the RAM and ROM self-test functions, I found that the custom pointer assignment statement was invalid and was not executed. The pointer variable was displayed as unassigned. I don't kno...
fjhdy1221 NXP MCU
Open a discussion thread about ADI laboratory circuits
I have been reading the information about ADI laboratory circuits for several hours. It is very interesting. I have started a thread to discuss it and share my experience with everyone....
chunyang ADI Reference Circuit
The simulation application of common mode inductors is here, full of useful information for everyone!
Author: Huang Gang, member of YiBo Technology Expressway First of all, let's clarify the questions that need to be solved in this article. There are mainly two. One is what role does the common-mode i...
yvonneGan PCB Design
Does surveillance data have legal effect?
When we were talking about how clear the surveillance video should be, a question came to mind: Does the surveillance data have legal effect? When mentioning this, two points came to mind: 1. Traffic ...
john_wang Industrial Control Electronics
Use memset function to assign values to char array
# Use memset function to assign values to char array Regarding the use of memory, memcpy function can easily assign values to array, but when a certain integer data is assigned to array using memcpy f...
bqgup Creative Market
Please answer the remote control decoding program using registers to set the 9MS boot code and 4.5MS result code detection method
Originally, this program uses a 10MS delay subroutine to detect the boot code, but after this design, there are many problems in the actual simulation decoding. The crystal oscillator of this hardware...
smilesmile13 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2808  1431  1289  293  751  57  29  26  6  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号