EEWORLDEEWORLDEEWORLD

Part Number

Search

LPT62-M

Description
PWR SUPPLY 60W 5/12/12V TRPL MED
CategoryPower/power management    The power supply circuit   
File Size813KB,3 Pages
ManufacturerArtysen Embedded Technologies
Environmental Compliance
Download Datasheet Parametric View All

LPT62-M Online Shopping

Suppliers Part Number Price MOQ In stock  
LPT62-M - - View Buy Now

LPT62-M Overview

PWR SUPPLY 60W 5/12/12V TRPL MED

LPT62-M Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerArtysen Embedded Technologies
package instruction,
Reach Compliance Codeunknown
Factory Lead Time18 weeks

LPT62-M Preview

POWER
Data Sheet
Total Power:
60 - 80 Watts
Input Voltage:
85 - 264 Vac
120 - 300 Vdc
# of Outputs:
Triple
SPECIAL FEATURES
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Medical safety approvals
Universal input
3” x 5” footprint
Remote sense on main output
Built-in EMI filter
Low output ripple
Adjustable 5V output
Overvoltage protection
Overload protection
110 KHz switching frequency
LPX60 enclosure kit available
RoHS compliant
LPT60-M Series
60 Watts
Electrical Specifications
Input
Input range
Frequency
Inrush current
Input current
85 - 264 Vac
120 - 300 Vdc
47 - 440 Hz
<18 A peak @ 115 Vac;
<36 A peak @ 230 Vac, cold start @ 25 °C
1.5A max. (RMS) @ 115VAC
70% typical at full load
FCC Class A conducted; CISPR 22 Class A conducted EN55022 Class
A conducted; VDE 0878 PT3 Class A conducted
<75 μA max. @ 50/60 Hz, 264 Vac input
SAFETY
ƒ
VDE
ƒ
UL
ƒ
CSA
ƒ
CE
0750/EN60601-1 (IEC601)
21310-3336-0015
UL2601
E182560
CSA 22.2 No. 601.1
LR109492
Mark (LVD)
Efficiency
EMI
Safety ground
leakage current
Output
Maximum power
Cross regulation
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Remote sense
60 W for convection; 80 W with 30CFW forced air
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20 ms @ 60 W load, 115 Vac nominal line
Short circuit protection on all outputs. Case overload protected @ 110%
to 145% above peak rating
5.7 to 6.7 Vdc on the main output
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
LPT60-M Series Data Sheet
Environmental Specifications
Operating temperature
Electromagnetic susceptibility
Humidity
Vibration
Storage temperature
Temperature coefficient
MTBF demonstrated
0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 °C to 70 °C, -20 °C startup
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 5G peak 5 Hz to
500 Hz, operational
-40 °C to 85 °C
±.04% per °C
>550,000 hours at full load and 25 °C ambient conditions
Ordering Information
Model Number
Output
Voltage
+5 V
+12 V
-12 V
+5 V
+15 V
-15 V
Minimum
Load
0.7 A
0.3 A
0A
0.7 A
0.3 A
0A
Maximum Load with Maximum Load with
Convection Cooling 30CFM Forced Air
7A
3A
0.7 A
7A
2.8 A
0.7 A
8A
3.5 A
1A
8A
3.3 A
1A
Peak Load
1
10 A
6A
1.5 A
10 A
4A
1.5 A
Regulation
2
±2%
±5%
±5%
±2%
±5%
±5%
Ripple
P/P (PARD)
3
50 mV
120 mV
120 mV
50 mV
150 mV
150 mV
LPT62-M
LPT63-M
1.
2.
3.
4.
Peak current lasting <30 seconds with a maximum 10% duty cycle.
At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges.
Minimum Loads are required.
5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as
a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System
Integrators, including through Distribution Channels. It is not intended for sale to End Users.
Power Derating Curve
80W
30 CFM Forced Air Cooling
60W
Output
Power
(Watts)
40W
20W
0W
Natural
Convection
Cooling
40W
30W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
LPT60-M Series Data Sheet
Mechanical Drawing
0.22"
(5.6)
M1
GND
SK201
4.55"
(115.6)
5.00"
(127)
M2
Remote Sense
Connector
Voltage
Adj. Pot
3.00"
(76.2)
2.55"
(64.8)
3
1
SK 1
SK 2
1
2
3
4
5
6
N
L
0.15" (4)
DIA (4 places)
1.69"
(42.9)
0.12"
(3)
Pin Assignments
Connector
SK1-1
SK1-3
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK201-1
SK201-2
LPT62-M
Line
Neutral
+12V
+5V
+5V
Common
Common
-12V
+Sense
-Sense
LPT63-M
Line
Neutral
+15V
+5V
+5V
Common
Common
-15V
+Sense
-Sense
Mating Connectors
AC Input
Molex 09-50-8031 (USA)
09-93-0300 (UK)
PINS: 08-58-0111
Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Molex 22-01-2025
PINS: 08-52-0113
DC Outputs
Remote Sense
Astec Connector Kit #70-841-006, includes all of the above
1.
2.
3.
4.
5.
Specifications subject to change without notice.
All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm)
Mounting holes M1 and M2 should be grounded for EMI purposes.
Mounting hole M1 is safety ground connection.
Specifications are for convection rating at factory settings at 115 VAC input,
25°C unless otherwise stated.
6. Warranty: 2 year
7. Weight: 0.75lbs/0.34kg
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
www.artesyn.com
For more information:
www.artesyn.com/power
For support:
productsupport.ep@artesyn.com
LPT60-M Series-DS 22Mar2016
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
LCD AND TOUCH BOOSTERPACK progress (recent photos)
[size=4][color=#ff0000]Thank you for your support, everyone is very concerned about the progress of LCD AND TOUCH BOOSTERPACK. [/color][/size] [size=4][color=#ff0000]Today is the weekend, I quickly to...
wstt Microcontroller MCU
Experiment 4.1: usb_dev_serial program example?
1. Experimental purpose Learn how to use serial port and USB to communicate with each other 2. Experimental equipment Computer (windows xp system) LM3S9B96 experimental evaluation board USB A-type mal...
喜鹊王子 Microcontroller MCU
Repost: Dad's joke
Dad's joke 1 Naming There is a boy in my high school class named He Nan. Because of this special name, the teacher often asks him to answer questions. Anyway, for him, "How difficult is it!" I was ver...
思念加祝 Talking
Beginners understand interrupt control serial port communication and routines
I believe that this understanding has confused beginners for a long time. Please give me some advice! I still want to control serial port communication with high-definition interrupts... Receiving int...
xinjitmzy stm32/stm8
Dynamic memory allocation confusion
#include "INCLUDES.h" #define TASK_STK_SIZE 512 /* Task stack length*/ OS_STK StartTaskStk[TASK_STK_SIZE]; /* Define task stack area*/ OS_STK MyTaskStk[TASK_STK_SIZE]; OS_MEM *IntBuffer; //Define memo...
haoandlong Real-time operating system RTOS
sopc software programming
An example based on sopc, I hope it will be helpful to everyone...
blueangell Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 725  2649  301  693  779  15  54  7  14  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号