EEWORLDEEWORLDEEWORLD

Part Number

Search

3100-15U19777C

Description
general purpose relays 40a 1pws 208/24
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size75KB,2 Pages
ManufacturerAll Sensors
Download Datasheet Parametric View All

3100-15U19777C Online Shopping

Suppliers Part Number Price MOQ In stock  
3100-15U19777C - - View Buy Now

3100-15U19777C Overview

general purpose relays 40a 1pws 208/24

3100-15U19777C Parametric

Parameter NameAttribute value
ManufactureTE Connectivity
Product CategoryGeneral Purpose Relays
Catalog 1308242
Issued 3-03 (PDF Rev. 3-04)
PRODUCTS UNLIMITED
Model 98 - 3100
series
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
3 Form X (3PST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
20, 25, 30 FLA Models
Type:
#10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size:
16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque:
25 in.-lbs.
40 FLA Models
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-4 Cu/Al AWG
Tightening Torque:
40 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects, standard.
A 0.250” quick connect and a #6-32 screw, optional.
Arc Cover:
Optional on 20-30 FLA models, standard on 40 FLA models.
Weight:
16 oz. (455 g) approximately
Coil Data @ 25°C
Voltage:
24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
20
Number
of
Poles
3
Line
Voltage
240/277
480
600
240/277
480
600
Locked
Rotor
Amps
120
100
80
150
125
100
Resistive
Amps
Rating
30
30
30
35
35
35
Voltage
110/120
200/240
480/600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
Maximum Horsepower
Single
Phase
1.5
3
-
2
-
5
-
-
2
-
5
-
-
3
-
7.5
-
-
Three
Phase
-
7.5
7.5
-
7.5
10
15
20
-
10
10
15
20
-
10
10
20
25
25
3
30
3
240/277
480
600
180
150
120
40
40
40
40
3
240/277
480
600
240
200
160
50
50
50
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
24
18
6 -15
60
53
6.0
5
7
120
88
20 - 70
60
53
6.0
5
180
208/240
177
40 - 140
60
53
6.0
5
720
277
220
65 - 185
60
53
6.0
5
950
480
384
150 - 270
65
53
6.0
5
3100
Dimensions are shown for
832
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
The inevitable trend of the development of video surveillance system
"In the field of video surveillance, users have higher and higher requirements for image clarity. How clear do users want to see and whether they have strong demands for details are the basis for the ...
xyh_521 Industrial Control Electronics
E-sports easy liquid filling
[i=s]This post was last edited by paulhyde on 2014-9-15 09:08[/i] Is there any expert who has done this and can teach me? ??? ???...
vivisect21 Electronics Design Contest
How to implement the help document function under EVC?
I want to implement a help document function in the application, and of course I need to add some pictures to the document. I wonder if any expert can help me? Thank you very much!...
笑哈哈 Embedded System
How to deal with the coupling problem of multi-process shared memory? ? Send points
Recently I encountered a synchronization problem of multi-process shared memory, which troubled me for several days (because I don't want to use Mute to lock, so I plan to write a simple one myself: (...
lwhay Embedded System
Question: lm3s graphics display program
GrCircleDraw(&sContext, 40, 105, 25);GrContextFontSet(sContext, g_sFontCmss16);GrStringDrawCentered(sContext, "PWM2", -1, 40, 105, 0);GrContextFontSet(sContext, g_sFontCmss26b);GrStringDrawCentered(sC...
喜鹊王子 Microcontroller MCU
There is a problem when using the atmega128 PF port.
#include#include#include #define uchar unsigned char #define uint unsigned int void delay_us(uint t) { uint j;for (j=0;j Changing the JTAG fuse bit doesn't work. Check if there are four pull-up resist...
shaoyuanfu Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2027  222  2274  2017  506  41  5  46  11  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号