K = ±10% 006 = 6Vdc C = Std ESR S = 13" T&R L = Group A
represent
J = ±5%
010 = 10Vdc L = Low ESR W = Waffle
M = MIL (JAN)
significant
015 = 15Vdc
CWR11
figures 3rd
020 = 20Vdc
See page 5
digit represents
025 = 25Vdc
for additional
multiplier
035 = 35Vdc
(number of
packaging
zeros to follow)
050 = 50Vdc
options.
Reliability Grade
Qualification Termination Finish
Level
Weibull:
H = Solder Plated
0 = N/A
B = 0.1%/1000 hrs.
0 = Fused Solder
90% conf.
Plated
9 = SRC9000
C = 0.01%/1000 hrs.
8 = Hot Solder
90% conf.
Dipped
D = 0.001%/1000 hrs.
9 = Gold Plated
90% conf.
7 = Matte Sn
T = T Level
(COTS-Plus only)
Z = Non-ER
CWR11 P/N CROSS REFERENCE:
CWR11
Type
D
Voltage
Code
C = 4Vdc
D = 6Vdc
F = 10Vdc
H = 15Vdc
J = 20Vdc
K = 25Vdc
M = 35Vdc
N = 50Vdc
^
Termination
Finish
H = Solder Plated
K = Solder Fused
C = Hot Solder
Dipped
B = Gold Plated
686
Capacitance
Code
pF code:
1st two digits
represent
significant
figures 3rd digit
represents
multiplier
(number of zeros
to follow)
*
Capacitance
Tolerance
M = ±20%
K = ±10%
J = ±5%
@
Reliability
Grade
Weibull:
B = 0.1%/1000 hrs.
90% conf.
C = 0.01%/1000 hrs.
90% conf.
D = 0.001%/1000
hrs. 90% conf.
T = T Level
A = Non-ER
+
Surge Test
Option
A = 10 cycles, +25°C
B = 10 cycles,
-55°C & +85°C
C = 10 cycles,
-55°C & +85°C
before Weibull
If blank,
None required
Packaging
Bulk = Standard
\TR = 7" T&R
\TR13 = 13" T&R
\W = Waffle
See page 5
for additional
packaging
options.
SPACE LEVEL OPTIONS TO SRC9000*:
TBJ D
Type
Case
Size
686
*
006
C
L
@
9
^
++
Surge Test
Option
00 = 10 Cycles,
-55ºC & +85ºC
45 = 10 cycles,
-55ºC & +85ºC
before Weibull
Capacitance Capacitance
Voltage
Standard or Packaging Inspection Level
Code
Tolerance
Code
Low ESR
L = Group A
B = Bulk
pF code:
M = ±20% 004 = 4Vdc
Range
R = 7" T&R
1st two digits
K = ±10% 006 = 6Vdc C = Std ESR S = 13" T&R
represent
J = ±5%
010 = 10Vdc L = Low ESR W = Waffle
significant
015 = 15Vdc
figures 3rd
020 = 20Vdc
See page 5
digit represents
025 = 25Vdc
for additional
multiplier
035 = 35Vdc
(number of
packaging
zeros to follow)
050 = 50Vdc
options.
Reliability Grade
Qualification Termination Finish
Level
Weibull:
H = Solder Plated
9 = SRC9000 0 = Fused Solder
B = 0.1%/1000 hrs.
90% conf.
Plated
C = 0.01%/1000 hrs.
8 = Hot Solder
90% conf.
Dipped
D = 0.001%/1000 hrs.
9 = Gold Plated
90% conf.
*Contact factory for AVX SRC9000 Space Level SCD details.
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage: (V
R
)
Category Voltage: (V
C
)
Surge Voltage: (V
S
)
Temperature Range:
Unless otherwise specified, all technical
0.1 μF to 100 μF
±5%; ±10%; ±20%
4
6
10
16
2.7
4
7
10
5.2
8
13
20
3.4
5
8
13
-55°C to +125°C
data relate to an ambient temperature of 25°C
85°C:
125°C:
85°C:
125°C:
20
13
26
16
25
17
32
20
35
23
46
28
50
33
65
40
27
TBJ Series
CWR11 - MIL-PRF-55365/8
Established Reliability, COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR11 P/N
CWR11C^225*@+
CWR11C^475*@+
CWR11C^685*@+
CWR11C^106*@+
CWR11C^156*@+
CWR11C^336*@+
CWR11C^686*@+
CWR11C^107*@+
CWR11D^155*@+
CWR11D^225*@+
CWR11D^335*@+
CWR11D^475*@+
CWR11D^685*@+
CWR11D^106*@+
CWR11D^156*@+
CWR11D^226*@+
CWR11D^476*@+
CWR11D^686*@+
CWR11F^105*@+
CWR11F^155*@+
CWR11F^225*@+
CWR11F^335*@+
CWR11F^475*@+
CWR11F^685*@+
CWR11F^156*@+
CWR11F^336*@+
CWR11F^476*@+
CWR11H^684*@+
CWR11H^105*@+
CWR11H^155*@+
CWR11H^225*@+
CWR11H^335*@+
CWR11H^475*@+
CWR11H^106*@+
CWR11H^226*@+
CWR11H^336*@+
CWR11J^474*@+
CWR11J^684*@+
CWR11J^105*@+
CWR11J^155*@+
CWR11J^225*@+
CWR11J^335*@+
CWR11J^475*@+
CWR11J^685*@+
CWR11J^156*@+
CWR11J^226*@+
CWR11K^334*@+
CWR11K^474*@+
CWR11K^684*@+
CWR11K^105*@+
CWR11K^155*@+
CWR11K^225*@+
CWR11K^335*@+
CWR11K^475*@+
CWR11K^685*@+
AVX COTS-Plus P/N
TBJA 225 * 004 C
TBJ A 475 * 004 C
TBJ B 685 * 004 C
TBJ B 106 * 004 C
TBJ B 156 * 004 C
TBJ C 336 * 004 C
TBJ D 686 * 004 C
TBJ D 107 * 004 C
TBJ A 155 * 006 C
TBJ A 225 * 006 C
TBJ A 335 * 006 C
TBJ B 475 * 006 C
TBJ B 685 * 006 C
TBJ B 106 * 006 C
TBJ C 156 * 006 C
TBJ C 226 * 006 C
TBJ D 476 * 006 C
TBJ D 686 * 006 C
TBJ A 105 * 010 C
TBJ A 155 * 010 C
TBJ A 225 * 010 C
TBJ B 335 * 010 C
TBJ B 475 * 010 C
TBJ B 685 * 010 C
TBJ C 156 * 010 C
TBJ D 336 * 010 C
TBJ D 476 * 010 C
TBJ A 684 * 015 C
TBJ A 105 * 015 C
TBJ A 155 * 015 C
TBJ B 225 * 015 C
TBJ B 335 * 015 C
TBJ B 475 * 015 C
TBJ C 106 * 015 C
TBJ D 226 * 015 C
TBJ D 336 * 015 C
TBJ A 474 * 020 C
TBJ A 684 * 020 C
TBJ A 105 * 020 C
TBJ B 155 * 020 C
TBJ B 225 * 020 C
TBJ B 335 * 020 C
TBJ C 475 * 020 C
TBJ C 685 * 020 C
TBJ D 156 * 020 C
TBJ D 226 * 020 C
TBJ A 334 * 025 C
TBJ A 474 * 025 C
TBJ B 684 * 025 C
TBJ B 105 * 025 C
TBJ B 155 * 025 C
TBJ C 225 * 025 C
TBJ C 335 * 025 C
TBJ C 475 * 025 C
TBJ D 685 * 025 C
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
Parametric Specifications by Rating per MIL-PRF-55365/8
Cap
DC Rated ESR @
DCL max
DF Max
@ 120Hz Voltage
100kHz
+25ºC
+85ºC
+125ºC
+25ºC
+(85/125)ºC
μF
V
Ohms
AVX SRC9000 P/N
Case
(μA)
(μA)
(μA)
(%)
(%)
@ 25ºC
@ +85ºC @ +25ºC
TBJ A 225 * 004 C L @ 0 ^ ++ A
2.2
4
8
0.5
5
6
6
9
TBJ A 475 * 004 C L @ 0 ^ ++ A
4.7
4
8
0.5
5
6
6
9
TBJ B 685 * 004 C L @ 9 ^ ++ B
6.8
4
5.5
0.5
5
6
6
9
TBJ B 106 * 004 C L @ 9 ^ ++ B
10
4
4
0.5
5
6
6
9
TBJ B 156 * 004 C L @ 9 ^ ++ B
15
4
3.5
0.6
6
7.2
6
9
TBJ C 336 * 004 C L @ 9 ^ ++ C
33
4
2.2
1.3
13
15.6
6
9
TBJ D 686 * 004 C L @ 9 ^ ++ D
68
4
1.1
2.7
27
32.4
6
9
TBJ D 107 * 004 C L @ 9 ^ ++ D
100
4
0.9
4
40
48
8
12
TBJ A 155 * 006 C L @ 9 ^ ++ A
1.5
6
8
0.5
5
6
6
9
TBJ A 225 * 006 C L @ 9 ^ ++ A
2.2
6
8
0.5
5
6
6
6
TBJ A 335 * 006 C L @ 9 ^ ++ A
3.3
6
8
0.5
5
6
6
9
TBJ B 475 * 006 C L @ 9 ^ ++ B
4.7
6
5.5
0.5
5
6
6
9
TBJ B 685 * 006 C L @ 9 ^ ++ B
6.8
6
4.5
0.5
5
6
6
9
TBJ B 106 * 006 C L @ 9 ^ ++ B
10
6
3.5
0.6
6
7.2
6
9
TBJ C 156 * 006 C L @ 9 ^ ++ C
15
6
3
0.9
9
10.8
6
9
TBJ C 226 * 006 C L @ 9 ^ ++ C
22
6
2.2
1.4
14
16.8
6
9
TBJ D 476 * 006 C L @ 9 ^ ++ D
47
6
1.1
2.8
28
33.6
6
9
TBJ D 686 * 006 C L @ 9 ^ ++ D
68
6
0.9
4.3
43
51.6
6
9
TBJ A 105 * 010 C L @ 9 ^ ++ A
1
10
10
0.5
5
6
4
6
TBJ A 155 * 010 C L @ 9 ^ ++ A
1.5
10
8
0.5
5
6
6
6
TBJ A 225 * 010 C L @ 9 ^ ++ A
2.2
10
8
0.5
5
6
6
9
TBJ B 335 * 010 C L @ 9 ^ ++ B
3.3
10
5.5
0.5
5
6
6
9
TBJ B 475 * 010 C L @ 9 ^ ++ B
4.7
10
4.5
0.5
5
6
6
9
TBJ B 685 * 010 C L @ 9 ^ ++ B
6.8
10
3.5
0.7
7
8.4
6
9
TBJ C 156 * 010 C L @ 9 ^ ++ C
15
10
2.5
1.5
15
18
6
6
TBJ D 336 * 010 C L @ 9 ^ ++ D
33
10
1.1
3.3
33
39.6
6
9
TBJ D 476 * 010 C L @ 9 ^ ++ D
47
10
0.9
4.7
47
56.4
6
9
TBJ A 684 * 015 C L @ 9 ^ ++ A
0.68
15
12
0.5
5
6
4
6
TBJ A 105 * 015 C L @ 9 ^ ++ A
1
15
10
0.5
5
6
4
6
TBJ A 155 * 015 C L @ 9 ^ ++ A
1.5
15
8
0.5
5
6
6
9
TBJ B 225 * 015 C L @ 9 ^ ++ B
2.2
15
5.5
0.5
5
6
6
9
TBJ B 335 * 015 C L @ 9 ^ ++ B
3.3
15
5
0.5
5
6
6
8
TBJ B 475 * 015 C L @ 9 ^ ++ B
4.7
15
4
0.7
7
8.4
6
9
TBJ C 106 * 015 C L @ 9 ^ ++ C
10
15
2.5
1.6
16
19.2
6
8
TBJ D 226 * 015 C L @ 9 ^ ++ D
22
15
1.1
3.3
33
39.6
6
8
TBJ D 336 * 015 C L @ 9 ^ ++ D
33
15
0.9
5.3
53
63.6
6
9
TBJ A 474 * 020 C L @ 9 ^ ++ A
0.47
20
14
0.5
5
6
4
6
TBJ A 684 * 020 C L @ 9 ^ ++ A
0.68
20
12
0.5
5
6
4
6
TBJ A 105 * 020 C L @ 9 ^ ++ A
1
20
10
0.5
5
6
4
6
TBJ B 155 * 020 C L @ 9 ^ ++ B
1.5
20
6
0.5
5
6
6
9
TBJ B 225 * 020 C L @ 9 ^ ++ B
2.2
20
5
0.5
5
6
6
8
TBJ B 335 * 020 C L @ 9 ^ ++ B
3.3
20
4
0.7
7
8.4
6
9
TBJ C 475 * 020 C L @ 9 ^ ++ C
4.7
20
3
1
10
12
6
8
TBJ C 685 * 020 C L @ 9 ^ ++ C
6.8
20
2.4
1.4
14
16.8
6
9
TBJ D 156 * 020 C L @ 9 ^ ++ D
15
20
1.1
3
30
36
6
8
TBJ D 226 * 020 C L @ 9 ^ ++ D
22
20
0.9
4.4
44
52.8
6
9
TBJ A 334 * 025 C L @ 9 ^ ++ A
0.33
25
15
0.5
5
6
4
6
TBJ A 474 * 025 C L @ 9 ^ ++ A
0.47
25
14
0.5
5
6
4
6
TBJ B 684 * 025 C L @ 9 ^ ++ B
0.68
25
7.5
0.5
5
6
4
6
TBJ B 105 * 025 C L @ 9 ^ ++ B
1
25
6.5
0.5
5
6
4
6
TBJ B 155 * 025 C L @ 9 ^ ++ B
1.5
25
6.5
0.5
5
6
6
8
TBJ C 225 * 025 C L @ 9 ^ ++ C
2.2
25
3.5
0.6
6
7.2
6
9
TBJ C 335 * 025 C L @ 9 ^ ++ C
3.3
25
3.5
0.9
9
10.8
6
8
TBJ C 475 * 025 C L @ 9 ^ ++ C
4.7
25
2.5
1.2
12
14.4
6
9
TBJ D 685 * 025 C L @ 9 ^ ++ D
6.8
25
1.4
1.7
17
20.4
6
9
-55ºC
(%)
9
9
9
9
9
9
9
12
9
9
9
9
9
9
9
9
9
9
6
9
9
9
9
9
9
9
9
6
6
9
9
9
9
9
9
9
6
6
6
9
9
9
9
9
9
9
6
6
6
6
9
9
9
9
9
25ºC
Dissipation
Ripple
A
W
(100kHz)
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.15
0.085
0.16
0.110
0.22
0.150
0.37
0.150
0.41
0.075
0.10
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.14
0.085
0.16
0.110
0.19
0.110
0.22
0.150
0.37
0.150
0.41
0.075
0.09
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.14
0.085
0.16
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.08
0.075
0.09
0.075
0.10
0.085
0.12
0.085
0.13
0.085
0.15
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.07
0.075
0.08
0.075
0.09
0.085
0.12
0.085
0.13
0.085
0.15
0.110
0.19
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.07
0.075
0.07
0.085
0.11
0.085
0.11
0.085
0.11
0.110
0.18
0.110
0.18
0.110
0.21
0.150
0.33
Power
Typical Ripple Data by Rating
85ºC
125ºC
25ºC
Ripple
Ripple
Ripple
A
A
V
(100kHz) (100kHz) (100kHz)
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.13
0.06
0.58
0.14
0.06
0.55
0.20
0.09
0.49
0.33
0.15
0.41
0.37
0.16
0.37
0.09
0.04
0.77
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.62
0.14
0.06
0.55
0.17
0.08
0.57
0.20
0.09
0.49
0.33
0.15
0.41
0.37
0.16
0.37
0.08
0.03
0.87
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.62
0.14
0.06
0.55
0.19
0.08
0.52
0.33
0.15
0.41
0.37
0.16
0.37
0.07
0.03
0.95
0.08
0.03
0.87
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.65
0.13
0.06
0.58
0.19
0.08
0.52
0.33
0.15
0.41
0.37
0.16
0.37
0.07
0.03
1.02
0.07
0.03
0.95
0.08
0.03
0.87
0.11
0.05
0.71
0.12
0.05
0.65
0.13
0.06
0.58
0.17
0.08
0.57
0.19
0.09
0.51
0.33
0.15
0.41
0.37
0.16
0.37
0.06
0.03
1.06
0.07
0.03
1.02
0.10
0.04
0.80
0.10
0.05
0.74
0.10
0.05
0.74
0.16
0.07
0.62
0.16
0.07
0.62
0.19
0.08
0.52
0.29
0.13
0.46
85ºC
Ripple
V
(100kHz)
0.70
0.70
0.62
0.52
0.49
0.44
0.37
0.33
0.70
0.70
0.70
0.62
0.56
0.49
0.52
0.44
0.37
0.33
0.78
0.70
0.70
0.62
0.56
0.49
0.47
0.37
0.33
0.85
0.78
0.70
0.62
0.59
0.52
0.47
0.37
0.33
0.92
0.85
0.78
0.64
0.59
0.52
0.52
0.46
0.37
0.33
0.95
0.92
0.72
0.67
0.67
0.56
0.56
0.47
0.41
125ºC
Ripple
V
(100kHz)
0.31
0.31
0.27
0.23
0.22
0.20
0.16
0.15
0.31
0.31
0.31
0.27
0.25
0.22
0.23
0.20
0.16
0.15
0.35
0.31
0.31
0.27
0.25
0.22
0.21
0.16
0.15
0.38
0.35
0.31
0.27
0.26
0.23
0.21
0.16
0.15
0.41
0.38
0.35
0.29
0.26
0.23
0.23
0.21
0.16
0.15
0.42
0.41
0.32
0.30
0.30
0.25
0.25
0.21
0.18
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
28
TBJ Series
CWR11 - MIL-PRF-55365/8
Established Reliability, COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR11 P/N
CWR11K^106*@+
CWR11K^156*@+
CWR11M^104*@+
CWR11M^154*@+
CWR11M^224*@+
CWR11M^334*@+
CWR11M^474*@+
CWR11M^684*@+
CWR11M^105*@+
CWR11M^155*@+
CWR11M^225*@+
CWR11M^335*@+
CWR11M^475*@+
CWR11M^685*@+
CWR11N^104*@+
CWR11N^154*@+
CWR11N^224*@+
CWR11N^334*@+
CWR11N^474*@+
CWR11N^684*@+
CWR11N^105*@+
CWR11N^155*@+
CWR11N^225*@+
CWR11N^335*@+
CWR11N^475*@+
AVX COTS-Plus P/N
TBJ D 106 * 025 C
TBJ D 156 * 025 C
TBJ A 104 * 035 C
TBJ A 154 * 035 C
TBJ A 224 * 035 C
TBJ A 334 * 035 C
TBJ B 474 * 035 C
TBJ B 684 * 035 C
TBJ B 105 * 035 C
TBJ C 155 * 035 C
TBJ C 225 * 035 C
TBJ C 335 * 035 C
TBJ D 475 * 035 C
TBJ D 685 * 035 C
TBJ A 104 * 050 C
TBJ B 154 * 050 C
TBJ B 224 * 050 C
TBJ B 334 * 050 C
TBJ C 474 * 050 C
TBJ C 684 * 050 C
TBJ C 105 * 050 C
TBJ D 155 * 050 C
TBJ D 225 * 050 C
TBJ D 335 * 050 C
TBJ D 475 * 050 C
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
Parametric Specifications by Rating per MIL-PRF-55365/8
Cap
DC Rated ESR @
DCL max
DF Max
@ 120Hz Voltage
100kHz
+25ºC
+85ºC
+125ºC
+25ºC
+(85/125)ºC
μF
V
Ohms
AVX SRC9000 P/N
Case
(μA)
(μA)
(μA)
(%)
(%)
@ 25ºC
@ +85ºC @ +25ºC
TBJ D 106 * 025 C L @ 9 ^ ++ D
10
25
1.2
2.5
25
30
6
8
TBJ D 156 * 025 C L @ 9 ^ ++ D
15
25
1
3.8
38
45.6
6
9
TBJ A 104 * 035 C L @ 9 ^ ++ A
0.1
35
24
0.5
5
6
4
6
TBJ A 154 * 035 C L @ 9 ^ ++ A
0.15
35
21
0.5
5
6
4
6
TBJ A 224 * 035 C L @ 9 ^ ++ A
0.22
35
18
0.5
5
6
4
6
TBJ A 334 * 035 C L @ 9 ^ ++ A
0.33
35
15
0.5
5
6
4
6
TBJ B 474 * 035 C L @ 9 ^ ++ B
0.47
35
10
0.5
5
6
4
6
TBJ B 684 * 035 C L @ 9 ^ ++ B
0.68
35
8
0.5
5
6
4
6
TBJ B 105 * 035 C L @ 9 ^ ++ B
1
35
6.5
0.5
5
6
4
6
TBJ C 155 * 035 C L @ 9 ^ ++ C
1.5
35
4.5
0.5
5
6
6
8
TBJ C 225 * 035 C L @ 9 ^ ++ C
2.2
35
3.5
0.8
8
9.6
6
8
TBJ C 335 * 035 C L @ 9 ^ ++ C
3.3
35
2.5
1.2
12
14.4
6
8
TBJ D 475 * 035 C L @ 9 ^ ++ D
4.7
35
1.5
1.7
17
20.4
6
8
TBJ D 685 * 035 C L @ 9 ^ ++ D
6.8
35
1.3
2.4
24
28.8
6
9
TBJ A 104 * 050 C L @ 9 ^ ++ A
0.1
50
22
0.5
5
12
6
8
TBJ B 154 * 050 C L @ 9 ^ ++ B
0.15
50
17
0.5
5
6
4
6
TBJ B 224 * 050 C L @ 9 ^ ++ B
0.22
50
14
0.5
5
6
4
6
TBJ B 334 * 050 C L @ 9 ^ ++ B
0.33
50
12
0.5
5
6
4
6
TBJ C 474 * 050 C L @ 9 ^ ++ C
0.47
50
8
0.5
5
6
4
6
TBJ C 684 * 050 C L @ 9 ^ ++ C
0.68
50
7
0.5
5
6
4
6
TBJ C 105 * 050 C L @ 9 ^ ++ C
1
50
6
0.5
5
6
4
6
TBJ D 155 * 050 C L @ 9 ^ ++ D
1.5
50
4
0.8
8
9.6
6
8
TBJ D 225 * 050 C L @ 9 ^ ++ D
2.2
50
2.5
1.1
11
13.2
6
8
TBJ D 335 * 050 C L @ 9 ^ ++ D
3.3
50
2
1.7
17
20.4
6
9
TBJ D 475 * 050 C L @ 9 ^ ++ D
4.7
50
1.5
2.4
24
28.8
6
9
-55ºC
(%)
9
9
6
6
6
6
6
6
6
9
9
9
9
9
8
6
6
6
6
6
6
9
9
9
9
25ºC
Dissipation
Ripple
A
W
(100kHz)
0.150
0.35
0.150
0.39
0.075
0.06
0.075
0.06
0.075
0.06
0.075
0.07
0.085
0.09
0.085
0.10
0.085
0.11
0.110
0.16
0.110
0.18
0.110
0.21
0.150
0.32
0.150
0.34
0.075
0.06
0.085
0.07
0.085
0.08
0.085
0.08
0.110
0.12
0.110
0.13
0.110
0.14
0.150
0.19
0.150
0.24
0.150
0.27
0.150
0.32
Power
Typical Ripple Data by Rating
85ºC
125ºC
25ºC
Ripple
Ripple
Ripple
A
A
V
(100kHz) (100kHz) (100kHz)
0.32
0.14
0.42
0.35
0.15
0.39
0.05
0.02
1.34
0.05
0.02
1.25
0.06
0.03
1.16
0.06
0.03
1.06
0.08
0.04
0.92
0.09
0.04
0.82
0.10
0.05
0.74
0.14
0.06
0.70
0.16
0.07
0.62
0.19
0.08
0.52
0.28
0.13
0.47
0.31
0.14
0.44
0.05
0.02
1.28
0.06
0.03
1.20
0.07
0.03
1.09
0.08
0.03
1.01
0.11
0.05
0.94
0.11
0.05
0.88
0.12
0.05
0.81
0.17
0.08
0.77
0.22
0.10
0.61
0.25
0.11
0.55
0.28
0.13
0.47
85ºC
Ripple
V
(100kHz)
0.38
0.35
1.21
1.13
1.05
0.95
0.83
0.74
0.67
0.63
0.56
0.47
0.43
0.40
1.16
1.08
0.98
0.91
0.84
0.79
0.73
0.70
0.55
0.49
0.43
125ºC
Ripple
V
(100kHz)
0.17
0.15
0.54
0.50
0.46
0.42
0.37
0.33
0.30
0.28
0.25
0.21
0.19
0.18
0.51
0.48
0.44
0.40
0.38
0.35
0.32
0.31
0.24
0.22
0.19
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
This is the homework assigned by the computer teacher. The schematic diagram of the 51 single-chip microcomputer simulation of police lights and sirens is as follows (the proteus simulation project fi...
Emacs is probably the most powerful text editing tool under Linux . This article is not a manual for emacs , but a guide for beginners to quickly start using emacs for simple text editing and processi...
How do you send data in the MDB protocol? For example, if the address is 08, is it followed by the command, data, and checksum? Or is the address in the upper 5 bits and the command in the lower 3 bit...
PSoC4 is finally here. I spent some time to run the development board and recorded the experimental process to share with you. Here, I would like to thank soso, eeworld, and Arrow Electronics for thei...
System design is a complex process. It is not enough to just use ICs. There are many details to consider. This article uses a high-fidelity music playback system as an example to introduce how to s...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
At present, how various communication technologies will evolve after 3G is a focus of great concern in the industry. Especially for TD-SCDMA, whether it can achieve smooth evolution to the next gen...[Details]
In the "digital pressure measurement" experimental device of applied physics, the subject technical knowledge of analog circuits, digital circuits, sensors and single-chip microcomputers is used. In o...[Details]
People who often surf the Internet until late at night, their families always complain that turning on the big lights in the living room affects their rest, but some people don't have keyboard ligh...[Details]
The future energy storage hotspot is not coal or iron ore, but lithium. This lightest metal in nature may be the heaviest resource in the future energy landscape. China launched an ambitious electr...[Details]
In order to prevent the lithium battery from being damaged by abnormal conditions such as overcharge, over discharge, and overcurrent, a lithium battery protection device is usually used to prevent...[Details]
1 Battery technology determines the fate of energy vehicles
Regardless of whether new energy vehicles are hybrid or pure electric vehicles, they cannot do without the core technology of batter...[Details]
The power supply is the core component of a computer. Although it is not of high value, all computer components rely on the switching power adapter to provide energy, so the stability of a power su...[Details]
1 Introduction
CAN (Controller Area Network) bus is a kind of field bus. It is used in many industrial sectors due to its outstanding advantages such as high performance, high reliability, high...[Details]