Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Compact 3-phase Delta RFI Filters for Universal Applications
BCF Series
UL Recognized
VDE Approved
BCF Series
• Designed for universal applications
• Compact book-form design
• Low weight
• Insulated, high quality safety terminals for input
and output
• Cost-effective design
• Good common and differential mode performance
below 100kHz
• Applications include; 3-phase inverters,
converters, variable speed motor drives and
process automation equipment
• Touch safe terminals provide easy connections
and prevent inadvertent contact for safety in the
most demanding applications
Specifications
Maximum leakage current each Line to Ground*:
@ 277 VAC 50 Hz:
30 mA
*If 2 phases are interrupted, this leakage current
may rise to a significantly higher level
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
Phase to Phase:
Phase to Ground:
Operating Frequency:
Rated Current:
1850 VAC
1850 VDC
480 VAC
277 VAC
50/60 Hz
7 to 180A
2
Three Phase Filters
Ordering Information
55 BCF 10
Input / Output Style
10 – Terminal block
BCF Series
Current Rating
7, 16, 30, 42, 55, 75,
100, 130 or 180A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +50°C
In an ambient temperature (Ta) higher than +50°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
(85-Ta)/35
Electrical Schematic
LINE
LOAD
Available Part Numbers
7BCF10
30BCF10
55BCF10
100BCF10
180BCF10
16BCF10
42BCF10
75BCF10
130BCF10
113
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Compact 3-phase Delta Filters for Universal Applications
(continued)
BCF Series
Case Style
Terminals
H
F
G
D
A
C
E
Part No.
7BCF10, 16BCF10
30BCF10
42BCF10
55BCF10
75BCF10
100BCF10, 130BCF10
180BCF10
B
Ground
Terminals
M5
M5
M6
M6
M6
M10
M10
Line/Load
Terminals
4mm²
10mm²
10mm²
16mm²
25mm²
50mm²
95mm²
L1
L2
L3
L1
L2
L3
Case Dimensions
Part No.
7BCF10
16BCF10
30BCF10
42BCF10
55BCF10
75BCF10
100BCF10
130BCF10
180BCF10
A
B
C
D
E
F
G
H
114
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Compact 3-phase Delta Filters for Universal Applications
(continued)
BCF Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
7BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
16BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
30BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
42BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
2
Three Phase Filters
55BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
75BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
100BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
130BCF10
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
180BCF10
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
115
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com