Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Features
s
s
s
s
s
s
s
North American and Metric fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Fast-on terminals or solder lug terminals
Metal case provides effective EMI shielding
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 43)
Computers and peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instruments
Telecommunications equipment
Tested and found to be
IAW VDE 0565 Part 3.
Fused Filtered
Power Entry Modules
Circuit Diagram
L
L
1
E
R
C
X
C
Y
N
C
Y
L
E
Applications
s
s
s
s
s
N
Specifications
Model*
64-XXX-020-3-11
64-XXX-020-5-11
64-XXX-020-3-12
64-XXX-020-5-12
64-XXX-040-3-11
64-XXX-040-5-11
64-XXX-040-3-12
64-XXX-040-5-12
64-XXX-060-3-11
64-XXX-060-5-11
64-XXX-060-3-12
64-XXX-060-5-12
65-XXX-020-3-11
65-XXX-020-5-11
65-XXX-020-3-12
65-XXX-020-5-12
65-XXX-040-3-11
65-XXX-040-5-11
65-XXX-040-3-12
65-XXX-040-5-12
65-XXX-060-3-11
65-XXX-060-5-11
65-XXX-060-3-12
65-XXX-060-5-12
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
Capacitance
C
Y
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
C
X
0.1uF
6.5mH
0.22uF
0.1uF
4.2mH
0.22uF
0.1uF
1.6mH
0.22uF
0.1uF
6.5mH
0.22uF
0.1uF
4.2mH
0.22uF
0.1uF
1.6mH
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
45°C
45°C
40°C
45°C
45°C
40°C
Inductance
(L
1
)
Temperature
Rise (Max.)
250VAC
2A
250VAC
4A
250VAC
6A
125VAC
2A
125VAC
4A
125VAC
6A
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
F(S) = Fast-on or (Solder lug terminals)
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
42
SPECTRUM CONTROL INC.
• 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Temperature Characteristics
120
1.738
(44.2)
2.32
(59)
.098
(2.5)
Fuse cover
1.376
(35)
1.298
(33)
1.29
(32.8)
Dimensions
64/65-BFF Series
1.101
(28)
100
80
60
1.416±.008
(36±0.2)
2 - .13
+.008
-.004
(2 - 3.3
+0.2
)
-0.1
Hole
0.252
(6.4)
1.616
(41.1)
1.14
(29)
Fast-on tab#250
t= .031
(0.8)
40
20
* Alternate Terminal for 64/65-BFS-Solder Lug Terminal
0.158
(4.0)
0
* General Tolerance:
±.020
(0.5)
* Metal Case
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
2.249 (L:57.2)
Dimensions in inches
(mm)
Common Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
50Ω
Level
Meter
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
50Ω
50Ω
Level
Meter
0.50 mA Leakage Versions
90
80
70
Insertion Loss (dB)
60
50
40
6 Amp
30
20
4 Amp
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
10
Insertion Loss (dB)
2 Amp
90
80
70
60
50
40
0.50 mA Leakage Versions
2 Amp
6 Amp
4 Amp
30
20
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0.35 mA Leakage Versions
90
80
Insertion Loss (dB)
Insertion Loss (dB)
70
60
50
40
6 Amp
30
20
4 Amp
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
2 Amp
90
80
70
0.35 mA Leakage Versions
2 Amp
60
50
40
6 Amp
30
20
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
4 Amp
SPECTRUM CONTROL INC.
• 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Fused Filtered
Power Entry Modules
43
Current (%)
Fused Filtered
Power Entry Modules
66-67-BFF/66-67-BFS Series
Features
s
For Medical or General Purpose Applications
s
s
s
s
s
s
s
s
Metric and North American fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Fast-on terminations or solder lug terminations
Metal case provides effective EMI shielding
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitance
Reduces the line to ground capacitance in order
to meet patient care requirements
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 45)
Tested and found to be
IAW VDE 0565 Part 3.
Fused Filtered
Power Entry Modules
Applications
s
s
s
s
Medical equipment
Electronic equipment
Digital equipment
Industrial equipment
s
s
s
Telecommunications equipment
Measuring and testing instruments
Personal computers
and peripherals
66/67-BFF(S)-XXX-0-X and
66/67-BFF(S)-XXX-4-X Filters
L
L
L
1
LOAD
E
LINE
R
E
C
Y
C
X
E
C
Y
LOAD
L
Circuit Diagrams
66/67-BFF(S)-XXX-1-X Filter
L
L
1
LINE
R
E
C
X
N
N
N
N
Specifications
Model*
66-XXX-020-1-11
66-XXX-020-1-12
66-XXX-020-0-11
66-XXX-020-4-11
66-XXX-020-0-12
66-XXX-020-4-12
66-XXX-040-1-11
66-XXX-040-1-12
66-XXX-040-0-11
66-XXX-040-4-11
66-XXX-040-0-12
66-XXX-040-4-12
66-XXX-060-1-11
66-XXX-060-1-12
66-XXX-060-0-11
66-XXX-060-4-11
66-XXX-060-0-12
66-XXX-060-4-12
67-XXX-020-1-11
67-XXX-020-1-12
67-XXX-020-0-11
67-XXX-020-4-11
67-XXX-020-0-12
67-XXX-020-4-12
67-XXX-040-1-11
67-XXX-040-1-12
67-XXX-040-0-11
67-XXX-040-4-11
67-XXX-040-0-12
67-XXX-040-4-12
67-XXX-060-1-11
67-XXX-060-1-12
67-XXX-060-0-11
67-XXX-060-4-11
67-XXX-060-0-12
67-XXX-060-4-12
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
0.01mA
250VAC
2A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
4A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
6A
0.075mA
0.1mA
0.075mA
0.1mA
0.005mA
125VAC
2A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
4A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
6A
0.035mA
0.05mA
0.035mA
0.05mA
Capacitance
C
Y
none
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
330pF
470pF
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
C
X
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
1.6mH
45°C
4.2mH
45°C
6.5mH
40°C
1.6mH
45°C
4.2mH
45°C
Inductance
(L
1
)
Temperature
Rise (Max.)
6.5mH
40°C
none
none
none
none
none
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
F(S) = Fast-on or (Solder lug terminals)
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
44
SPECTRUM CONTROL INC.
• 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Fused Filtered
Power Entry Modules
66-67-BFF/66-67-BFS Series
Temperature Characteristics
120
100
80
60
40
20
For Medical or General Purpose Applications
Dimensions
66-67-BFF/66-67-BFS Series
1.738
(44.2)
1.101
(28)
Fuse cover
1.376
(35)
1.298
(33)
1.416±.008
(36±0.2)
1.29
(32.8)
2.32
(59)
.098
(2.5)
2 - .13
+.008
-.004
(2 - 3.3
+0.2
)
-0.1
Hole
0.252
(6.4)
1.616
(41.1)
1.14
(29)
Fast-on tab#250
t= .031
(0.8)
* Alternate Terminal for 66/67-BFS-Solder Lug Terminal
0.158
(4.0)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
2.249 (L:57.2)
* General Tolerance:
±.020
(0.5)
* Metal Case
Dimensions in inches
(mm)
Common Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
50Ω
Level
Meter
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
50Ω
50Ω
Level
Meter
0.01 mA Leakage Current
90
80
70
Insertion Loss (dB)
Insertion Loss (dB)
60
50
40
30
20
10
0
0.1
0.2
4 Amp
6 Amp
10
1
2
5
Frequency (MHz)
10
20
50
2 Amp
90
80
70
60
50
40
30
20
0.01 mA Leakage Current
2 Amp
4 Amp
6 Amp
0.5
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0.075 and 0.1 mA Leakage Current
90
80
70
Insertion Loss (dB)
Insertion Loss (dB)
60
50
40
30
20
10
0
0.1
0.2
4 Amp
6 Amp
10
1
2
5
Frequency (MHz)
10
20
50
2 Amp
90
80
70
60
50
40
30
0.075 and 0.1 mA Leakage Current
2 Amp
4 Amp
20
6 Amp
0.5
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC.
• 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH
• Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Fused Filtered
Power Entry Modules
45
Current (%)