10EHZ1

Description
AC power line filters 10a 250v spade term
CategoryThe connector   
File Size316KB,3 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric Compare View All

10EHZ1 Online Shopping

Suppliers Part Number Price MOQ In stock  
10EHZ1 - - View Buy Now

10EHZ1 Overview

AC power line filters 10a 250v spade term

10EHZ1 Parametric

Parameter NameAttribute value
ManufactureTE Connectivity
Product CategoryAC Power Line Filters
RoHSYes
Voltage Rating250 VAC
Current Rating10 A
Mounting StyleScrew
Termination StyleSpade Terminal
Factory Pack Quantity12
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
High Performance Power Line Filter for Medical Applications
HZ Series
UL Recognized
CSA Certified
VDE Approved
1
RFI Power Line Filters
Specifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
2
A
@250 VAC 50 Hz:
5
A
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
Operating Frequency:
Rated Current:
2250 VDC
1450 VDC
250 VAC
50/60 Hz
3 to 30A
HZ Series
• Designed to provide good attenuation to RFI noise
in the frequency range from 10kHz to 30MHz
• Size and cost-effective
• Low leakage current
• New versions up to 30A
Ordering Information
3 E HZ 1
Input / Output Style
1 – .250 [6.3] spade terminals
6 – Threaded bolt
HZ Series
Leakage current designation
E – Low leakage
(<0.5 mA)
Current Rating
3, 4, 6, 10, 15, 20 or 30A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
(85-Ta)/45
Case Styles
3EHZ1
Available Part Numbers
B
3EHZ1
6EHZ1
15EHZ1
30EHZ6
4EHZ1
10EHZ1
20EHZ1
D
E
A

½
½½

C
Electrical Schematic
LINE
LOAD



43
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com

10EHZ1 Related Products

10EHZ1 30EHZ6 4EHZ1 6EHZ1 15EHZ1
Description AC power line filters 10a 250v spade term AC power line filters 30a 250vac threaded AC power line filters 4A 250vac spade term AC power line filters 6A 250vac spade term AC power line filters 15a 250v spade term
Manufacture TE Connectivity TE Connectivity TE Connectivity TE Connectivity TE Connectivity
Product Category AC Power Line Filters AC Power Line Filters AC Power Line Filters AC Power Line Filters AC Power Line Filters
RoHS Yes Yes Yes Yes Yes
Voltage Rating 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC
Current Rating 10 A 30 A 4 A 6 A 15 A
Mounting Style Screw Screw Screw Screw Screw
Termination Style Spade Terminal Threaded Bol Spade Terminal Spade Terminal Spade Terminal
Factory Pack Quantity 12 8 40 9 12
I don't understand this hardware problem. Please help.
Has anyone made an amplifier and comparison circuit? I've been working on something that needs a comparison circuit, but I just can't figure it out. It's so annoying. It seems that the chip uses lm386...
Codemaster Embedded System
There is a strange problem with stm32 driving LCD in keil online debugging. I don’t know the reason. Anyone with debugging experience can help me take a look!
I modified the LCD driver function myself, and the project compilation and linking were fine. After downloading it to the stm32 board, the LCD screen was white, and the reset, power-off, and power-on ...
秦皇 stm32/stm8
Poll: What operating system are you using now? (Thank you for participating)
[i=s] This post was last edited by lcofjp on 2017-10-15 15:39 [/i] I am currently writing a serial port application software, which is mainly for electricians. However, this software does not support ...
lcofjp Embedded System
Findfirstfile traversal file problem
I found an example online. It always has to check strcmp(fd.cFileName, ".") && strcmp(fd.cFileName, ".."). What is this used to judge?...
heeroz Embedded System
SYMBOL data collector (MC1000) crash problem
Hello everyone, my question is, why does the MC1000 program I made freeze after scanning about 10 bars? What caused the error? I'm offering RMB 200 to seek the answer. If anyone knows or can solve my ...
szgaoju Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1243  1679  1290  2852  2207  26  34  58  45  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号