Power Entry Modules with Line Filter
www.schurter.com /PG06
5707
Medical fuse drawer
IEC Appliance Inlet C14 or C18 with Filter, Protection Degree IP65 into the Appliance, Fuseholder 1- or
2-pole, Front or Rear Mounting
5707.xxxx.xx2 Mounting from front side
5707.xxxx.xxx.22 with IP 54 V-Lock cord con-
nection
5707 with IP 54 Inlet Gasket
C14
70° C
C18
70° C
Description
- Panel Mount :
Screw-on version from front or rear side , Screws with sealing are in-
cluded
- 4 Functions :
Appliance Inlet protection class I or II , Line filter in standard and medi-
cal version , Fuseholder for fuse-links 5 x 20 mm , IP 65 protection into
the appliance
- For front side mounting versions a sealing kit IP 54 for the power sup-
ply connection is available as an accessory: 4700.0021
- Option suffix ".22" offers IP 54 for the power input in combination with
V-Lock cordsets
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
-
-
-
-
-
-
Extreme robust design
All single elements are already wired
Screw type fuse carrier, slotted
With EMC-shield
Especially for applications in rough environments
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
With solder terminals
Class X1- and Y1-capacitors for enhanced withstand voltage
Medical version M80
Additional factory-mounted sealing (IP54) of power input
Version with current rating 3 A
Other versions on request
-
-
-
-
-
Unique Selling Proposition
-
-
-
-
Sealed power entry module
Strong in Design and Safety
IP 65 protection to the appliance
IP 54 protection to the cord connection
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Approvals
- Approval Reference Type: 5707
- VDE Certificate Number: 40016382
- UL File Number: E72928
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 8 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 8 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 65 acc. to IEC 60529
from rear-side IP 65 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw, max 3 mm
Mounting screw torque max 0.8 Nm
2 screws M3 with sealing are provided
black / white / metallic, UL 94V-0
appliance inlet/-outlet
C14 / C18 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 8 A,
Protection Class I or II
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 1.6 W 1-pole/ 1,2 W 2-pole per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'800'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Filter
MTBF
Material: Housing
EMC Products
1