5707.0201.313

Description
AC power entry modules 2A with filter
CategoryThe connector    The connector   
File Size803KB,7 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

5707.0201.313 Overview

AC power entry modules 2A with filter

5707.0201.313 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time10 weeks
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498; CSA C22.2; VDE, IP65; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2A, 125/250VAC
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialMETAL
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power Entry Modules with Line Filter
www.schurter.com /PG06
5707
Medical fuse drawer
IEC Appliance Inlet C14 or C18 with Filter, Protection Degree IP65 into the Appliance, Fuseholder 1- or
2-pole, Front or Rear Mounting
5707.xxxx.xx2 Mounting from front side
5707.xxxx.xxx.22 with IP 54 V-Lock cord con-
nection
5707 with IP 54 Inlet Gasket
C14
70° C
C18
70° C
Description
- Panel Mount :
Screw-on version from front or rear side , Screws with sealing are in-
cluded
- 4 Functions :
Appliance Inlet protection class I or II , Line filter in standard and medi-
cal version , Fuseholder for fuse-links 5 x 20 mm , IP 65 protection into
the appliance
- For front side mounting versions a sealing kit IP 54 for the power sup-
ply connection is available as an accessory: 4700.0021
- Option suffix ".22" offers IP 54 for the power input in combination with
V-Lock cordsets
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
-
-
-
-
-
-
Extreme robust design
All single elements are already wired
Screw type fuse carrier, slotted
With EMC-shield
Especially for applications in rough environments
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
With solder terminals
Class X1- and Y1-capacitors for enhanced withstand voltage
Medical version M80
Additional factory-mounted sealing (IP54) of power input
Version with current rating 3 A
Other versions on request
-
-
-
-
-
Unique Selling Proposition
-
-
-
-
Sealed power entry module
Strong in Design and Safety
IP 65 protection to the appliance
IP 54 protection to the cord connection
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Approvals
- Approval Reference Type: 5707
- VDE Certificate Number: 40016382
- UL File Number: E72928
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 8 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 8 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 65 acc. to IEC 60529
from rear-side IP 65 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw, max 3 mm
Mounting screw torque max 0.8 Nm
2 screws M3 with sealing are provided
black / white / metallic, UL 94V-0
appliance inlet/-outlet
C14 / C18 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 8 A,
Protection Class I or II
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 1.6 W 1-pole/ 1,2 W 2-pole per
pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'800'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Filter
MTBF
Material: Housing
EMC Products
1

5707.0201.313 Related Products

5707.0201.313 5707.0805.313 5707.0105.313 5707.0405.313 5707.0405.312 5707.0205.313
Description AC power entry modules 2A with filter AC power entry modules 8A with filter m80 AC power entry modules 1A with filter m80 AC power entry modules 4A with filter m80 AC power entry modules 4A with filter m80 AC power entry modules 2A with filter m80
Manufacture - Schurte Schurte Schurte Schurte Schurte
Product Category - AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules AC Power Entry Modules
RoHS - Yes Yes Yes Yes Yes
Filtered - Yes Yes Yes Yes Yes
Produc - Inlets Inlets Inlets Inlets Inlets
Current Rating - 8 A 1 A 4 A 4 A 2 A
Voltage Rating - 250 V 250 V 250 V 250 V 250 V
Housing Material - Metallic Metallic Metallic Metallic Metallic
Mounting Style - Screw Screw Screw Screw Screw
Termination Style - Quick Connec Quick Connec Quick Connec Quick Connec Quick Connec
Operating Temperature Range - - 25 C to + 85 C - 25 C to + 85 C - 25 C to + 85 C - 25 C to + 85 C - 25 C to + 85 C
Connector Type - IEC-950 IEC-950 IEC-950 IEC-950 IEC-950
Flammability Rating - UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0 UL 94 V-0
Fused - Yes Yes Yes Yes Yes
Factory Pack Quantity - 10 10 10 10 10
Switch Functi - Not Switched Not Switched Not Switched Not Switched Not Switched
Unit Weigh - 95.760 g 95.760 g 95.760 g 95.760 g 95.760 g
Help with top-level files
写了一个顶层文件,如下entity top isPort ( CLK : inSTD_LOGIC;RX : inSTD_LOGIC;rst : inSTD_LOGIC;GPIO : inoutSTD_LOGIC_VECTOR (0 downto 0);TX : outSTD_LOGIC; INT : out STD_LOGIC_VECTOR (0 downto 0));end top;archit...
qd0090 FPGA/CPLD
Looking for the upgrade password for Zhuoyi 5518G (green shell)
My Zhuoyi 5518G (green shell) has a 7-pin upgrade interface, which is Haier 2023+1108EGa+5812. I have read many forums but cannot find any information or specific operation methods to upgrade by direc...
janeyqian Embedded System
Analyzing a simple CPLD program problem
As the title:The hardware is the EPM570T100C5N development board. The small light flashing function cannot be realized. The small light can be controlled separately (it can only be turned on and off, ...
eeleader FPGA/CPLD
Aircraft tracking
How to see the aircraft tracks?...
沙沙清木子 Electronics Design Contest
Case Study: DB SDK Bank Mobile Commerce Application Case
With the vigorous development of financial business, banking business has developed rapidly, and the number of users has continued to rise exponentially. How to provide better and more convenient serv...
cmmht9800gt RF/Wirelessly
Problem with busybox configuration for making root file system
I installed Ubuntu 9.1 and compiled the kernel linux-2.6.22.6. When I used busybox 1.7.0 to create the root file system, although the configuration interface appeared, when I entered a certain option ...
青城山下 Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1572  2577  1229  497  66  32  52  25  10  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号