Features
Regulated
Converters
●
●
●
●
●
●
●
●
AC-DC Power Supply
60 Watt PCB Mount Package
Universal Input Voltage Range
4kVAC Isolation RMS
Low Output Ripple and Noise
Short Circuit Protected
Output Trim
UL Certified, CE Marked
POWERLINE
AC/DC-Converter
with 3 year Warranty
Description
Compact high power switching power module for PCB mounting.
This switching converter has an universal AC or DC input voltage range
with single high current outputs which are trimmable to compensate for
any voltage drops on the output connections. Threaded inserts ensure
mechanical fixing.
Selection Guide
Part
Number
RAC60-05SB
RAC60-09SB
RAC60-12SB
RAC60-15SB
RAC60-24SB
RAC60-48SB
Input
Range
(VAC)
85-265
85-265
85-265
85-265
85-265
85-265
Output
Voltage
(VDC)
5
9
12
15
24
48
Output
Current
(mA)
10000
6600
5000
4000
2500
1250
Output Efficiency
Max
Power at 230V Capacitive
(W)
%
Load
50
60
60
60
60
60
82
84
86
86
86
86
80000µF
28000µF
14000µF
12000µF
4000µF
950µF
60 Watt
Single
Output
Specifications
(typical at 25°C and after warm up time unless otherwise specified )
Input Voltage Range
Rated Power
Input Frequency Range (for AC Input)
Input Current (full load)
115VAC/230VAC
115VAC/230VAC
115VAC/230VAC
85-265VAC or 100-370VDC
60 Watts max.
47-63Hz
2A/ 1A max.
520mW max.
30A/ 50A max.
3.5mA max.
±2%
Single
±1% typ.
±1% typ.
1%
0.5%Vout + 50mVp-p max
<0.2%Vout + 40mVp-p max
±10%
100kHz typ.
see table
4kVAC / 1 minute
±0.02%/°C typ.
100 MOhm max.
Output Power (%)
2011/65/EU
6/6
RoHS
E196683
UL-60950-1 Certified
RAC60-B
No Load Power Consumption
Inrush Current (<2mS)
Leakage Current
Output Voltage Accuracy (Full load)
Line Voltage Regulation (LL to HL at full load)
Minimum Load
Output Noise (20MHz limited)
Output Ripple (20MHz limited)
Output Trim
Operating Frequency
Efficiency at Full Load
RMS Isolation Voltage (input to output)
Temperature Coefficient
Isolation Resistance
Short Circuit Protection
Operating Temperature Range
Storage Temperature Range
Humidity
Case Material
Package Weight
Packing Quantity
EMC
RAC60-B
Derating Graph
(Ambient Temperature)
125
100
75
60
50
25
0
-40 -20
-30
0
Load Voltage Regulation (5% to 100% full load) Single
Natural
Convection
62.5% (24V/48V)
50% (12V/15V)
25% (5V/9V)
60 70 80
45 50 55
Continuous, Hiccup, Automatic Restart
free air convection, with derating
-40°C to +70°C
-40°C to +85°C
95% RH max.
Plastic Resin with Fibreglass (UL94V-0)
310g
1 pc
EN 55011 Class B / EN 55022 Class B / EN 60601-1-2/ EN61000-3-2 -3
EN 55024 / EN61000-4-2 -3 -4 -5 -6 - 8 -11
>130 x 10³ hours
REV: 0/2014
Ambient Temperature Range (°C)
MTBF (using MIL-HDBK-217F, 25°C)
PA-44
Please Read Application Notes
www.recom-power.com
POWERLINE
AC/DC-Converter
Package Style and Pinning
RAC60-SB
Series
58.5
109.0
30.0
6.00
96.32
6.1
1.8
1.2
Pin Connections – Single Output
6.1
13.70
1
19.05
2
3
Bottom View
4
5
6
M3
Threaded
Insert
x4
mounting inserts 97.3
13.82
8.90
5.08
mounting
inserts
46.3
Pin #
1
2
3
4
5
6
Dia.(mm)
1.2
1.8
1.8
1.2
1.8
1.8
Function
FG
VAC in (L)
VAC in (N)
Trim
-VDC Out
+VDC Out
10.16
5.85
Tolerance ± 0.5 mm
Output Trim Adjustment
RAC60-B
-Vout
Trim Up
Trim
Trim Down
+Vout
10k
W
Trimpot
10k
W
Trimpot
-Vout
Trim
10k
W
Trimpot
+Vout
Standard Application Circuit
Suggested fuse rating
4A Slow Blow
L
Fuse
VACin (L)
Vout+
C1(Optional)
0.1uF
25V
C2(Optional)
47uF
50V
Load
N
VACin (N)
Vout-
The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.
The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property.
www.recom-international.com
REV:0/2014