ED Series
• AC output Solid State Relay in an Industry standard
EMR plug in package
• Ratings of 3 & 5 Amps
• Load voltage range of 24-280VAC
• Fits standard DIN rail & PCB mountable sockets
• LED input status indicator
• AC or DC control
• cUL Recognized, IEC Rated, CE & RoHS Compliant
• Horsepower Rated, Pilot Duty Rated
PRODUCT SELECTION
Description
3-15 VDC Control
18-32 VDC Control
48-72 VDC Control
18-36 VAC Control
90-140 VAC Control
3A
ED24D3
ED24C3
ED24F3
5A
ED24D5
ED24C5
ED24F5
ED24E5
ED24B5
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS AC Output (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Resistive Load Current UL 508/ IEC 62314 LC-A [Arms, FLA] (2)
Minimum Load Current [Arms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum Surge Current (50/60 Hz, 1 cycle) [Apk]
Maximum I²t for Fusing (50/60 HZ, 1/2 cycle) [A² sec]
UL 508 HP/IEC 62314 LC-B Rating @ 240V, 40°C [HP/KW]
Minimum Power Factor (with Maximum Load)
3A
24-280
600
3
0.15
0.1
500
1.1
240/250
285/260
0.25 / 0.37
0.5
5A
24-280
600
5
0.15
0.1
500
1.1
600/625
1780/1620
0.5 / 0.55
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Maximum Reverse Voltage
Minimum Input Current [mA]
Maximum Input Current [mA]
Nominal Input Impedance [ohms]
Maximum Turn-On Time [msec] (4)
Maximum Turn-Off Time [msec]
ED24Dx
3-15 VDC
3 VDC
1.9 VDC
6 VDC
3.8
33.8
500
8.33
8.33
ED24Cx
18-32 VDC
18 VDC
10.5 VDC
6 VDC
3.8
6.9
4.8K
8.33
8.33
ED24Fx
48-72 VDC
48 VDC
24 VDC
6 VDC
3.8
5.8
12.5K
8.33
8.33
ED24Ex
18-36 VAC
18 VAC
10 VAC
N/A
3.8
8.5
4.5K
20
30
ED24Bx
90-140 VAC
90 VAC
48 VAC
N/A
3.2
4.9
28K
20
30
GENERAL SPECIFICATIONS (1)
Description
Dielectric Strength, Input/Output (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Maximum Humidity
Housing Material
Terminals Material
Parameters
3750 Vrms
10
9
Ohms
10 pF
-30ºC to 80ºC
-40ºC to 125ºC
1.06 oz. (30 g)
85% non-condensing
Polyamide Class V0 (UL94)
Copper w/Sulfamet Nickel finish
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Based on 17mm (5A model) and 13mm (3A model) spacing minimum between parts.
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
4) Turn-On time for Random turn-on versions is 0.1ms for DC control and 5ms for AC control.
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
Pilot Duty Rated
C300
IEC 61000-4-2 : Electrostatic Discharge
Level 3 – Criteria A
IEC 61000-4-4 : Electrically Fast Transients
Level 3 – Criteria B
IEC 61000-4-5 : Electrical Surges
Level 3 – Criteria A
E116949
Rev 031312
ACCESSORIES