EEWORLDEEWORLDEEWORLD

Part Number

Search

389FHXXC1-120A

Description
general purpose relays 389f power relay spst-NO-DM, 30a
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size655KB,4 Pages
ManufacturerMagnecraft(Schneider Electric)
Websitehttp://www.magnecraft.de
Environmental Compliance
Download Datasheet Parametric View All

389FHXXC1-120A Online Shopping

Suppliers Part Number Price MOQ In stock  
389FHXXC1-120A - - View Buy Now

389FHXXC1-120A Overview

general purpose relays 389f power relay spst-NO-DM, 30a

389FHXXC1-120A Parametric

Parameter NameAttribute value
ManufactureSchneider Electric
Product CategoryGeneral Purpose Relays
RoHSYes
ProducPower Relays
TypeStandard
Termination StyleQuick Connect Terminal
Mounting StyleSocke
Contact FormSPST (1 Form X)
Contact Current Rating30 A
Coil TypeNon-Latching
Coil Voltage110 VAC to 120 VAC
Coil Resistance1.1 kOhms
Switching Voltage600 V
Contact MaterialSilver Alloy
Coil TerminatiQuick Connect Terminal
Power Consumpti3.5 VA/1.44 W
Factory Pack Quantity10
389F Power Relays/One,
Two or Three Pole 20-30 Amp Rating (DC and AC)
Oversized current carrying parts
to run cooler and last longer
Full range of contact ratings
to meet a wide variety of
applications
A variety of covers and
mounting options
Up to 30A switching for
power applications
600 V spacing can handle
most loads
Terminals for 0.25”
Quick Connects
Can be customized for
unique situations
WHITE
UL Recognized
File No. E43641
Contact Viewing Window
Gold Flashed Contacts
Square Base
General Specifications - (UL 508)
Contact Characteristics
Number and type of contacts
Contact materials
Thermal (carrying) current
Maximum switching voltage
Resistive
Switching current @
voltage
Ballast
HP
389FHXX, XHX
SPST-NO-DM, SPDT-DM-DB
Silver Alloy
30 A
600 V
30 A @ 300 VAC 50/60Hz
30 A @ 28 VDC
25 A @ 277 VAC 50/60Hz
1.5 @ 200-300 V 50/60Hz
1 @ 120-199 V 50/60Hz
A600
100 mA @ 5 VDC or 0.5 W
12 to 240 VAC
12 to 110 VDC
85% to 110% AC
80% to 110% DC
3.5 VA
1.44 W
10% AC/DC
100,000 operations
5,000,000 operations
20 ms
2000 VAC
2000 VAC
500 VAC
UL, CE, CSA
-40 to 85 °C
-40 to 55 °C
88 g
389FXAX, BXX, XBX
SPST, SPDT, DPST, DPDT
Silver Alloy
25 A
600 V
25 A @ 300 VAC 50/60Hz
13 A @ 28 VDC
20 A @ 277 VAC 50/60Hz
1.5 @ 208-240 V 50/60Hz
1 @ 480-600 V 50/60Hz
B600
100 mA @ 5 VDC or 0.5 W
12 to 240 VAC
12 to 110 VDC
85% to 110% AC
80% to 110% DC
3.5 VA
1.44 W
10% AC/DC
100,000 operations
5,000,000 operations
20 ms
2000 VAC
2000 VAC
500 VAC
UL, CE, CSA
-40 to 85 °C
-40 to 55 °C
88 g
389FCXX, XCX
3PST, 3PDT
Silver Alloy
20 A
300 V
20 A @ 150 VAC 50/60Hz
13 A @ 28 VDC
20 A @ 150 VAC 50/60Hz
6.67 A @ 277 VAC 50/60Hz
0.5 @ 208-240 V 50/60Hz
0.5 @ 120 V 50/60Hz
B300
100 mA @ 5 VDC or 0.5 W
12 to 240 VAC
12 to 110 VDC
85% to 110% AC
80% to 110% DC
3.5 VA
1.44 W
10% AC/DC
100,000 operations
5,000,000 operations
20 ms
2000 VAC
2000 VAC
500 VAC
UL, CE, CSA
-40 to 85 °C
-40 to 55 °C
88 g
Pilot Duty
Minimum switching requirement
Coil Characteristics
Voltage range
Operating range (% of nominal)
Average consumption
Drop-out voltage threshold
Performance Characteristics
Electrical life (operations @ rated current)
Mechanical life (unpowered)
Operating time (response time)
Between coil and
contact
Dielectric strength
Between poles
Between contacts
Environment
Product certifications
Standard version
Ambient air temperature Storage
around the device
Operation
Weight
SECTION 6
Part Number Builder
389F
Series
389F =
Standard model
equipped with flag indicator
XBX
Configuration
XAX =
SPDT
BXX =
DPST-NO
XBX =
DPDT
CXX =
3PST-NO
XCX =
3PDT
HXX =
SPST-NO-DM
XHX =
SPDT-DM-DB
C1M
Options**
B =
Mounting base
C =
Plastic dust cover - socket mountable
C1 =
Side flange mount cover
C3 =
Top flange cover
L =
Indicator lamp across coil
M =
Manual operator button on case
T =
Printed circuit board terminals
-120
Voltage
Coil Voltage
A
Current Type
A =
AC
D =
DC
Note - Not all iterations of option codes are available and some standard parts may use different nomenclature than outlined in part number builder.
**Multiple codes may be used.
6/12
M a gn e c r a ft S o lu t io n G ui de 1 0 5 A
28027 Ask for help with the problem encountered in the flash download program
Hello everyone! I'm a newbie! I bought a TI launchpad development board to practice. When using the RAM cmd (28027_RAM_lnk.cmd) file, I successfully downloaded my program to the RAM. It can work when ...
shiguangjiqiren TI Technology Forum
Why is the output of this DCDC unstable?
I used a DCDC (as shown in the picture) MP2143 from MPS. During use, I found that the output would fluctuate greatly when I touched it, causing the system to restart or freeze. After checking, I found...
elec32156 Switching Power Supply Study Group
DM8168 encoding 100fps incorrect
I am using the dvrrdk development kit. Currently, I need to collect two channels of 256x256 video data from the video port. The collection is normal, but when encoding, I can never reach 100fps, and i...
zhangke DSP and ARM Processors
Why can't the SysTick_Config function be directly located in the project file copied directly from STM32?
[i=s] This post was last edited by 天涯海角sr on 2018-9-6 23:49 [/i] [SysTick_Config is defined in core_cm3.h, and core_cm3.h is referenced in stm32f10x.h] 1. First of all, all the files related to the pr...
天涯海角sr stm32/stm8
Has anyone participated in an electronic design competition in college?
[i=s]This post was last edited by paulhyde on 2014-9-15 09:15[/i] Has anyone participated in an electronic design competition in college? I hope you can discuss it together....
fighting Electronics Design Contest
Bosch uses LM3S6911, I wonder how its supply is?
Bosch uses LM3S6911, I wonder how its supply is?...
o0pingu0o Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2372  794  828  547  945  48  16  17  12  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号