EEWORLDEEWORLDEEWORLD

Part Number

Search

C200H-OD218

Description
safety relays 32 PT out cpu 21/23/31/H
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size433KB,38 Pages
ManufacturerAll Sensors
Environmental Compliance  
Download Datasheet Parametric View All

C200H-OD218 Online Shopping

Suppliers Part Number Price MOQ In stock  
C200H-OD218 - - View Buy Now

C200H-OD218 Overview

safety relays 32 PT out cpu 21/23/31/H

C200H-OD218 Parametric

Parameter NameAttribute value
ManufactureOm
Product CategorySafety Relays
RoHSYes
ORDERING GUIDE
PRODUCT PERFORMANCE
STANDARDS
OMRON devices that comply with EC Directives
also conform to the related EMC standards so
that they can be more easily built into other
devices or the overall machine. The actual
products have been checked for conformity to
EMC standards (see the following note). Whether
the products conform to the standards in the
system used by the customer, however, must be
confirmed by the customer.
EMC-related performance of the OMRON devices
that comply with EC Directives will vary
depending on the configuration, wiring, and other
conditions of the equipment or control panel on
which the OMRON devices are installed. The
customer must, therefore, perform the final
check to confirm that devices and the overall
machine conform to EMC standards.
Applicable EMC Standards
EMS (Electromagnetic Susceptibility): EN61131-2
EMI (Electromagnetic Interference): EN50081-2
(Radiated emission: 10-m regulations)
CPU Rack
. . . . . . . . . . . . . . . . . . . . . . . . . . 147
Expansion Racks
. . . . . . . . . . . . . . . . . . . . 148
C200H Basic I/O Modules
. . . . . . . . . . . . . . 149
B7A Terminals
Link Master Adapters for High-density
I/O PLC Modules
System Overview
C200H High-density I/O Modules
. . . . . . . . 153
Connectors for C200H High-density I/O Modules
C200H Group-2 High-density
I/O Modules
. . . . . . . . . . . . . . . . . . . . . . . . 154
Connectors for C200H Group-2
High-density I/O Modules
CPU Overview
CS1 High-density I/O Modules
. . . . . . . . . . 155
Connectors for CS1 High-density I/O Modules
High-density I/O Screw Terminal Blocks
and Cables
. . . . . . . . . . . . . . . . . . . . . . . . . 156
Screw Terminal Block and Cables
Basic System Configuration
High-density I/O Relay Blocks, Bases
and Dedicated Cables
. . . . . . . . . . . . . . . . . 157
G7TC Relay Blocks
P7TF Block Bases and I/O Relays
Accessories
Relay Output Blocks
Relay Terminal Block Bases
Relays for use with G70A Bases
Dedicated Connecting Cable for Omron PLC Modules
OMRON Power Supply Modules and I/O Modules
have been determined safe when operating at
voltages of 50 to 1,000 VAC and 75 to 1,500 VDC
according to the safety standards in EN61131-2.
Standards Description
U = UL, Underwriters Laboratories, Inc.
C = CSA, Canadian Standards Association
CE = CE, CE Marking
N = Nemko, Norges Elektriske Materiellkontroll
L = Lloyd’s Register of shipping
Special Note: For current consumption, refer to
Current Consumption Tables
(the last 6 pages
of this ordering guide).
I/O Types and Allocations
C200H Special I/O Modules
. . . . . . . . . . . . 160
CS1 Special I/O Modules
. . . . . . . . . . . . . . 165
CS1/C200H Non-compatible Modules
. . . . . 167
Modules not compatible with CS1 Controllers
or Systems
Modules
CS1 Communications and
Network Modules
. . . . . . . . . . . . . . . . . . . . 168
Communications and Network Modules
Fiber-Optic Cables and Connectors for
Controller Link
DeviceNet Products
. . . . . . . . . . . . . . . . . . 169
DeviceNet Multiple I/O Terminal Modules
. 170
DeviceNet Communications Module
Digital I/O Modules
Relay Output Modules
Analog I/O Modules
Counter Module
Peripheral Hardware
and Software
CompoBus/S Slave Modules
. . . . . . . . . . . . 171
Long Distance CompoBus/S
Slave Modules (NEW!)
. . . . . . . . . . . . . . . . 172
Optional Products
. . . . . . . . . . . . . . . . . . . . 173
Module Accessories
Mounting Rails and Accessories
Instruction Set
Current Consumption Tables
. . . . . . . . . . . . 174
CPU Racks and Expansion Racks
SYSMAC BUS Slave Racks
Example Calculations
5 VDC Voltage Group . . . . . . . . . . . . . . . . . . . . .176
Basic I/O Modules
High-density I/O Modules (Special I/O)
Special I/O Modules
CS1 CPU BUS Modules
26 VDC Modules . . . . . . . . . . . . . . . . . . . . . . . .181
Ordering Guide
Reference Information

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2317  447  246  533  2034  47  9  5  11  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号