EEWORLDEEWORLDEEWORLD

Part Number

Search

DR48D12

Description
solid state relays - industrial mount 600vac/12a 4-32vdc 18mm DR ssr
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size1MB,7 Pages
ManufacturerAll Sensors
Environmental Compliance  
Download Datasheet Parametric View All

DR48D12 Online Shopping

Suppliers Part Number Price MOQ In stock  
DR48D12 - - View Buy Now

DR48D12 Overview

solid state relays - industrial mount 600vac/12a 4-32vdc 18mm DR ssr

DR48D12 Parametric

Parameter NameAttribute value
ManufactureCrydom
Product CategorySolid State Relays - Industrial Mou
RoHSYes
Control Voltage Range4 VDC to 32 VDC
Load Voltage Rating48 V to 600 VDC
Load Current Rating12 A
Output DeviceSCR
Mounting StyleDIN Rail
Factory Pack Quantity10
Termination StyleScrew
SeriesOne DR Series
• Ratings of 6 & 12 Amps
• Load voltage ratings of 1-60VDC, 1-100VDC, 24-280VAC and 48-600VAC
• Fits standard 35mm DIN-RAIL
• LED input status indicator
• AC or DC control
• Zero-crossing (resistive loads) or random turn-on (inductive loads) output
• UL and cUL Listed, HP Rated CE & RoHS Compliant
• UL 508 Endurance Rating for Enhanced Reliability
PRODUCT SELECTION
Description
4-32 VDC Control
90-140 VAC Control
200-265 VAC Control
18-36 VAC Control
280V, 6A
DR24D06
DR24B06
DR24A06
280V, 12A
DR24D12
DR24B12
DR24A12
600V, 6A
DR48D06
600V, 12A
DR48D12
DR48B12
DR48A12
60V, 6A
DR06D06
60V, 12A
DR06D12
100V, 6A
DR10D06
100V, 12A
DR10D12
DR24E06
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS AC Output (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Load Current, resistive [Arms] (2)
Minimum Load Current [Arms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum Surge Current (50/60 Hz, 1 cycle) [Apk]
Maximum I²t for Fusing (50/60 HZ, 1/2 cycle) [A² sec]
HP Rating UL 508/IEC60947 [HP (KW)] @ 240V
HP Rating UL 508/IEC60947 [HP (KW)] @ 380V
HP Rating UL 508/IEC60947 [HP (KW)] @ 480V
Minimum Power Factor (with Maximum Load)
Min/Max stranded wire
Min/Max solid wire
Weight (typical)
DR24x06
24-280
600
6
0.15
0.1
500
1.3
285/300
410/375
1/2 (.37)
1 (.75)
2 (1.5)
0.5
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR24x12
24-280
600
12
0.15
0.1
500
1.3
715/750
2560/2330
1 (.75)
2 (1.5)
3 (2.2)
0.5
22/14 AWG
22/14 AWG
3.17 oz. (90g)
DR48X06
48-600
1200
6
0.15
0.1
500
1.3
285/300
410/375
1/2 (.37)
1 (.75)
2 (1.5)
0.5
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR48x12
48-600
1200
12
0.15
0.2
500
1.3
715/750
2560/2330
1 (.75)
2 (1.5)
3 (2.2)
0.5
22/14 AWG
22/14 AWG
3.17 oz. (90g)
How to read data in continuous memory?
It is known that several different variable values are stored in the continuous memory, and these variable values change all the time. How to read these variable values? Write them to a *.txt file. Fo...
naphu Embedded System
 What should we pay attention to during the embedded learning process?
[i=s]This post was last edited by heiyanquan714 on 2018-7-27 14:07[/i] In the process of learning embedded systems, everyone must have doubts about its reliability. What should we pay attention to in ...
heiyanquan714 Embedded System
Where are the compressed volumes?
I downloaded several compressed files from the forum, but cannot decompress them. It prompts me to compress them into volumes. Where can I find them?...
zhangjun1960 Microcontroller MCU
Learning Ti Sitara (I)
[align=left]In the spare time of the past few days, I will study the Sitara starter kit of Texas Instruments (TI). Because there are few tutorials related to the processor used in this learning kit, a...
yangking91 DSP and ARM Processors
VxWorks heroes, please take a look, thank you~
Hi everyone, I encountered a problem when using the tornado 2.2 help and would like to ask for advice. I selected the menu "Help" -> "Manuals index" in the tornado interface, and the "Tornado online m...
shenjq Real-time operating system RTOS
Why can't I download the debugger directly to NANDFLASH under VS2005+CE60 (EVC+CE50 can)? Must I add a prefix like CSIDL_XXX? How to add NANDFLASH
Why can't I download the debugger directly to NANDFLASH under VS2005+CE60 (EVC+CE50 can)? Must I add a prefix like CSIDL_XXX? NANDFLASH still doesn't work even if I add a prefix like this?...
torresgerrard Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 676  1105  2224  1696  1469  14  23  45  35  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号