Sealed Snap Action Switch
D2JW
Immersion-Proof Subminiature Snap
Action Switch
• Ultra-small and highly sealed
• Water-tight housing conforming to IEC IP67
• Wide range of operating temperature from -40° to 85°C
• Gold crossbar contact and coil spring offer long life
expectancy and high reliability
• RoHS Compliant
Ordering Information
Actuator
Solder terminal
Model
Molded lead wires
Pin plunger
D2JW-011
D2JW-011-MD
Short hinge lever
D2JW-01K1A1
D2JW-01K1A1-MD
Hinge lever
D2JW-01K11
D2JW-01K11-MD
Simulated roller lever
D2JW-01K31
D2JW-01K31-MD
Hinge roller lever
D2JW-01K21
D2JW-01K21-MD
Note:
The length of the standard molded lead wire (AVS0.3) is 30 cm (12 in).
Model Number Legend
D2JW-01
1 2
1.
- -
3 4
2.
Actuator
None:
Pin plunger
K1A: Short hinge lever
K1:
Hinge lever
K3:
Simulated roller lever
K2:
Hinge roller lever
3.
Contact Form
1:
SPDT
2:
SPST-NC*
3:
SPST-NO*
*Lead
wire versions
only
4.
Terminals
None:
Solder terminals
MD: Molded lead
wires
Ratings
01:
0.1 A at 30
VDC
Note:Consult
Omron regarding SPST-NO and SPST-NC models.
Sealed Snap Action Switch
D2JW
189
Specifications
■
Characteristics
Operating speed (see note 2)
Operating frequency
Contact resistance
Insulation resistance
Dielectric strength (See note 3)
1 mm to 250 mm/second
Mechanical: 240 operations per minute max.
Electrical: 30 operations per minute max.
100 mΩ max. (Molded lead type: 140 mΩ min.)
100 MΩ min. (at 500 VDC)
600 VAC, 50/60 Hz for 1 minute between terminals of same polarity
1,000 VAC, 50/60 Hz for 1 minute between current-carrying metal part and ground, and between each
terminal and noncurrent-carrying metal part
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Destruction: 1,000 m/s
2
(approx. 100G) max.
Malfunction: 200 m/s
2
(approx. 20G) max.
-40° to 85°C (at 60% RH) with no icing or condensation
35% to 98% (for 5°C to 35°C)
IEC IP67 (excluding the terminals on terminal models)
Class I
175
Mechanical: 1,000,000 operations min. at 60 operations per minute
Electrical: 100,000 operations min. at 30 operations per minute
Approx. 7 g (pin plunger with molded lead wire models)
Vibration resistance (See note 4)
Shock resistance (See note 4)
Ambient operating temperature
Ambient operating humidity
Degree of protection
Degree of protection against
electric shock
Proof tracking index (PRTI)
Service life
Weight
Note: 1.
2.
3.
4.
Data shown are of initial value.
The values are for pin plunger type.
The dielectric strength values shown apply when using a separator (terminal type)
The values shown apply for malfunctions of 1 ms max.
■
Ratings
Electrical rating
0.1 A, 30 VDC (resistive load)
Note:
The ratings apply under the following test conditions:
Ambient Temperature = 20
±
2
°
C,
Ambient Humidity = 65
±
5%,
Operating frequency = 30 operations/min.
■
Contact Specifications
Item
Specification
Material
Gap (standard value)
Inrush current
Minimum applicable load
(see note)
Specification
Crossbar
Gold alloy
0.5 mm
0.1 A max.
1 mA at 5 VDC
Note:
Minimum applicable loads are indicated by N standard refer-
ence values. This value represents the failure rate at a 60%
(λ
60
) reliability level (JIS C5003).
The equation
λ
60
=0.5 x 10
-6
/ operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
Engineering Data
■
Construction
Rubber seal
(silicone rubber)
Cover
(PBT)
■
Contact Form
SPDT
SPST-NC
SPST-NO
COM
NO
NC
(Black*) (Blue*) (Red*)
COM
(Black)
NC
(Red)
COM
(Black)
NO
(Blue)
*Indicates the color of the lead
wire.
Soldered
Epoxy resin
COM
Black
NO
Blue
Red
NC
190
Sealed Snap Action Switch
D2JW
Dimensions
■
Terminals
Note:
Unless otherwise specified, all units are in millimeters and a tolerance of
±0.4
mm applies to all dimensions
Solder Terminals
Molded Lead Wires
15.3
1.3
1
2
3.95 3.95
3.95
3.95
0.4
300 ± 10
NC
(red)
NO
(blue)
COM
(black)
5±2
8.7
5.3 ± 0.1
■
Mounting
All switches may be panel mounted using M2.3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.20 to 0.29 N·m.
M2.3 mounting holes
4.8
±
0.1
■
Dimensions and Operating Characteristics
Note: 1.
Unless otherwise specified, all units are in millimeters and a tolerance of
±0.4
mm applies to all dimensions
2.
The following illustrations and dimensions are for models with PCB terminals. Refer to “Terminals” for models with molded lead wires.
3.
The operating characteristics are for operation in the A direction( )
Pin Plunger Models
D2JW-011
PT
1.6 dia.
A
OP
9.4
2.8
2.35
–0.025
+0.05
+0.05
OF max.
RF min.
12.3
250 gf
100 gf
0.6 mm
0.3 mm
0.1 mm
8.1
±
0.3 mm
PT max.
OT min.
0.4
5.3
±0.1
1.3
1
2
4.8
±0.05
3.95
3.95 3.95
12.7
+0.05
2.35
–0.025
dia.
MD max.
OP
2.5
–0.025
dia.
Short Hinge Lever Models
D2JW-01K1A1
1.8
PT
11.5R
7.95
A 0.3 t stainless-steel
spring lever
3
OF max.
RF min.
PT max.
OT min.
117 gf
23 gf
5.4 mm
0.7 mm
0.5 mm
8.4
±
0.8 mm
OP
6.15
9.4
2.8
2.35
–0.025
+0.05
12.3
MD max.
OP
0.4
5.3
±0.1
1.3
1 2.35
+0.05
dia.
–0.025
2
4.8
±0.05
3.95
3.95 3.95
12.7
2.5
–0.025
dia.
+0.05
Sealed Snap Action Switch
D2JW
191
Note: 1.
Unless otherwise specified, all units are in millimeters and a tolerance of
±0.4
mm applies to all dimensions
2.
The following illustrations and dimensions are for models with PCB terminals. Refer to “Terminals” for models with molded lead wires.
3.
The operating characteristics are for operation in the A direction( )
Hinge Lever Models
D2JW-01K11
PT
1.8
7.95
16.5R
A 0.3 t stainless-steel
spring lever
3
OF max.
OP
6.15
9.4
12.3
2.8
2.35
–0.025
1
2.5
–0.025
dia.
4.8
±0.05
3.95
3.95 3.95
12.7
+0.05
+0.05
82 gf
16 gf
6.4 mm
1.4 mm
0.7 mm
8.4
±
0.8 mm
RF min.
PT max.
OT min.
MD max.
OP
2.35
–0.025
dia.
+0.05
1.3
0.4
5.3
±0.1
2
Simulated Roller Lever Models
D2JW-01K31
PT
1.8
7.95
5.35
A
1.3R
OP
6.15
1.3 1.9
3
0.3 t stainless-steel
spring lever
OF max.
RF min.
PT max.
OT min.
MD max.
97 gf
20 gf
5.5 mm
1.1 mm
0.6 mm
10.3
±
0.8 mm
9.4
2.8
12.3
OP
+0.05
2.35
–0.025
1.3
1
2.35
–0.025
dia.
+0.05
+0.05
2.5
–0.025
dia.
2
4.8
±0.05
3.95
3.95 3.95
12.7
0.4
5.3
±0.1
Hinge Roller Lever Models
D2JW-01K21
PT
1.8
7.95
A
4.8 dia.
×
2.2 resin roller
OF max.
RF min.
PT max.
OT min.
MD max.
OP
12.3
100 gf
20 gf
5.2 mm
1.1 mm
0.5 mm
14.6
±
0.8 mm
13.5R
OP
6.15
9.4
2.8
2.35
–0.025
+0.05
+0.05
1.3
1
2
4.8
±0.05
3.95
3.95 3.95
12.7
2.35
+0.05
dia.
–0.025
0.4
5.3
±0.1
2.5
–0.025
dia.
192
Sealed Snap Action Switch
D2JW
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■
Protection against chemicals
Prevent the switch from coming into contact with oil and chemicals.
Otherwise, damage to or deterioration of switch materials may result.
Because the switch uses polycarbonate resin as material for its com-
ponent parts, contact OMRON if the switch material is likely to deteri-
orate due to adherence of oil or chemicals to the switch housing.
■
Degree of Protection
The D2JW satisfies the following test condition specified by the IEC
Publication 529 (Degree of Protection by Enclosure):
Degree of protection: IP67
Test method: See the figure below.
■
Soldering
To solder the lead to the terminal, apply a soldering iron rated at
30 W max. (temperature of soldering iron: 250°C max.) for no more
than 3 seconds.
Note that if soldering is not carried out under the proper conditions, there
is a danger of over-heating and subsequent heat damage.
Applying a soldering iron for more than three seconds or using one that
is rated at more than 30 W may degrade the switch characteristics.
Leave the test piece in water for 30 minutes with the top of the test
piece submerged 15 cm or more below the water level and the bot-
tom of the test piece submerged 1 m or more below the water level.
This test is to check the ingress of water into the switch enclosure
after submerging the switch in water for a given time. Note that even
if this test condition is met, the switch cannot be used in water.
■
Operation
Make sure that the operating body pushes the switch actuator with
an adequate force when the switch is to be operated, and that it does
not touch the actuator when the switch is released.
Install the pin plunger switch so that the operating force is applied in
alignment with the stroke of the actuator.
Do not apply excessive force to the actuator; otherwise, the switch
may be damaged.
■
Separator
When mounting the switch on a metallic surface, be sure to provide a
separator between the switch and the mounting plates.
Reference the following dimensions when designing the separator;
Two, 2.4±0.1 dia.
10.4
5.2
4.8
±0.05
12
t=0.18
Sealed Snap Action Switch
D2JW
193