Notes: (Ref) – Dimensions provided for reference only. No dimensions are provided for B, P or R because low profile cases do not have a bevel or a notch.
* MIL–PRF–55365/8 specified dimensions
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
6.3
6.3
6.3
10
16
16
16
20
25
25
35
35
35
VDC
Rated
Cap
µF
680
1000
1000
470
680
680
330
100
150
220
100
68
100
15
33
47
µF
Case Code/
Case Size
KEMET/EIA
X/7343-43
X/7343-43
E/7360-38
X/7343-43
X/7343-43
E/7360-38
X/7343-43
D/7343-31
X/7343-43
X/7343-43
X/7343-43
X/7343-43
E/7360-38
D/7343-31
X/7343-43
X/7343-43
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T513X687(1)004(2)(3)(4)(5)
T513X108(1)004(2)(3)(4)(5)
T513E108(1)004(2)(3)(4)(5)
T513X477(1)006(2)(3)(4)(5)
T513X687(1)006(2)(3)(4)(5)
T513E687(1)006(2)(3)(4)(5)
T513X337(1)010(2)(3)(4)(5)
T513D107(1)016(2)(3)(4)(5)
T513X157(1)016(2)(3)(4)(5)
T513X227(1)016(2)(3)(4)(5)
T513X107(1)020(2)(3)(4)(5)
T513X686(1)025(2)(3)(4)(5)
T513E107(1)025(2)(3)(4)(5)
T513D156(1)035(2)(3)(4)(5)
T513X336(1)035(2)(3)(4)(5)
T513X476(1)035(2)(3)(4)(5)
(See below for
part options)
DC
Leakage
μA @ +20ºC
Max/5 Min
27.2
40.0
40.0
29.6
42.8
42.8
33.0
16.0
24.0
35.2
20.0
17.0
25.0
5.3
11.6
16.5
μA @ +20ºC
Max/5 Min
DF
% @ +20ºC
120 Hz Max
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
10.0
8.0
8.0
8.0
6.0
6.0
8.0
% @ +20ºC
120 Hz Max
Standard
ESR
mΩ @ +20ºC
100 kHz Max
30
23
18
30
45
23
35
75
40
40
45
45
50
100
65
65
mΩ @ +20ºC
100 kHz Max
Low ESR
mΩ @ +20ºC
100 kHz Max
N/A
18
10
N/A
23
12
N/A
N/A
30
25
40
N/A
N/A
N/A
55
55
mΩ @ +20ºC
100 kHz Max
Ultra-low
ESR
mΩ @ +20ºC
100 kHz Max
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
35
N/A
N/A
N/A
N/A
N/A
mΩ @ +20ºC
100 kHz Max
Rated Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
Standard ESR
Low ESR
Ultra-low ESR
(1) To complete KEMET part number, insert M for ±20%, K for ±10%. Designates Capacitance tolerance.
(2) To complete KEMET part number, insert B (0.1%/1,000 hours), or A = N/A. Designates Reliability Level.
(3) To complete KEMET part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder Plated, K = Solder Fused or T = 100% Tin (Sn). Designates
Termination Finish.
(4) To complete KEMET part number, insert 61 = None, 62 = 10 cycles +25°C, 63 = 10 cycles -55°C +85°C after Weibull or 64 = 10 cycles -55°C +85°C before
Weibull. Designates Surge current option.
(5) To complete KEMET part number, insert 10 = Standard ESR, 20 = Low ESR or 30 = Ultra Low ESR. Designates ESR option.
Refer to Ordering Information for additional detail.
1. Basic use of RTC
In the routine, an experimental example of RTC is provided. With the cooperation of the serial port, the initial value of RTC can be set, and the RTC timing value can be output thr...
This program attempts to convert the input signal into the reset and start signal in the program after de-bouncing. The en signal is suitable, but the reset signal has been high after conversion, whic...
The experience is a bit behind, today I will test it by creating a new DEMO, and then transplant our SHT20 sensor to let our L436 development board read the temperature and humidity values.
First, we ...
Several suggestions on how to make good tax control bidding work [align=center]Several suggestions on how to make good tax control cash register bidding work[/align] Tax control cash register product ...