Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
T2054_T499_AUTO • 8/17/2021
4
Tantalum Surface Mount Capacitors – Automotive Grade
T499 Automotive Grade MnO
2
175°C
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC at 85°C
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
VDC at 85°C
Rated
Cap
µF
4.7
6.8
10
15
22
22
33
33
47
47
68
100
150
1.5
2.2
3.3
4.7
4.7
6.8
6.8
10
10
15
15
22
22
33
33
47
68
100
220
1
1.5
2.2
3.3
3.3
4.7
6.8
6.8
6.8
10
10
15
22
22
33
µF
Case
Code/
Case
Size
KEMET/EIA
A/3216-18
B/3528-21
B/3528-21
B/3528-21
B/3528-21
C/6032-28
B/3528-21
C/6032-28
C/6032-28
D/7343-31
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
A/3216-18
B/3528-21
A/3216-18
B/3528-21
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
C/6032-28
D/7343-31
D/7343-31
D/7343-31
D/7343-31
X/7343-43
A/3216-18
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
A/3216-18
B/3528-21
C/6032-28
B/3528-21
C/6032-28
C/6032-28
C/6032-28
D/7343-31
D/7343-31
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T499A475(1)006A(2)E6K0
T499B685(1)006A(2)E3K5
T499B106(1)006A(2)E3K5
T499B156(1)006A(2)E3K5
T499B226(1)006A(2)E3K5
T499C226(1)006A(2)E1K8
T499B336(1)006A(2)E3K0
T499C336(1)006A(2)E1K8
T499C476(1)006A(2)E1K8
T499D476(1)006A(2)E800
T499C686(1)006A(2)E1K2
T499D107(1)006A(2)E800
T499D157(1)006A(2)E700
T499A155(1)010A(2)E8K0
T499A225(1)010A(2)E8K0
T499A335(1)010A(2)E6K0
T499A475(1)010A(2)E6K0
T499B475(1)010A(2)E3K5
T499A685(1)010A(2)E6K0
T499B685(1)010A(2)E3K5
T499B106(1)010A(2)E3K5
T499C106(1)010A(2)E1K8
T499B156(1)010A(2)E3K5
T499C156(1)010A(2)E1K8
T499B226(1)010A(2)E3K0
T499C226(1)010A(2)E1K8
T499C336(1)010A(2)E1K8
T499D336(1)010A(2)E1K6
T499D476(1)010A(2)E800
T499D686(1)010A(2)E800
T499D107(1)010A(2)E700
T499X227(1)010A(2)E500
T499A105(1)016A(2)E10K
T499A155(1)016A(2)E8K0
T499A225(1)016A(2)E6K0
T499A335(1)016A(2)E6K0
T499B335(1)016A(2)E3K5
T499B475(1)016A(2)E6K0
T499A685(1)016A(2)E7K0
T499B685(1)016A(2)E3K5
T499C685(1)016A(2)E1K8
T499B106(1)016A(2)E3K5
T499C106(1)016A(2)E1K8
T499C156(1)016A(2)E1K8
T499C226(1)016A(2)E1K6
T499D226(1)016A(2)E800
T499D336(1)016A(2)E800
(See below for
part options)
DC
Leakage
µA at +25°C
Max/5 Min
0.5
0.5
0.6
0.9
1.4
1.4
2.1
2.1
3.0
3.0
4.3
6.3
9.5
0.5
0.5
0.5
0.5
0.5
0.7
0.7
1.0
1.0
1.5
1.5
2.2
2.2
3.3
3.3
4.7
6.8
10.0
22.0
0.5
0.5
0.5
0.5
0.5
0.8
1.1
1.1
1.1
1.6
1.6
2.4
3.5
3.5
5.3
µA at +25°C
Max/5 Min
DF
ESR
Maximum Allowable
Ripple Current (rms)
mA at
+85°C 100
kHz
101
140.4
140
140
140
222
151
222
222
390
273
390
417
87
87
101
101
140
101
140
140
222
140
222
151
222
222
275
390
390
417
517
78
87
101
101
140
107
94
140
222
140
222
222
236
390
390
mA at
+85°C 100
kHz
mA at
+125°C 100
kHz
45
62.4
62
62
62
99
67
99
99
173
121
173
185
39
39
45
45
62
45
62
62
99
62
99
67
99
99
122
173
173
185
230
35
39
45
45
62
48
42
62
99
62
99
99
105
173
173
mA at
+125°C 100
kHz
Maximum
Operating
Temp
°C
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
°C
MSL
Reflow
Temp
≤ 260°C
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow
Temp
≤ 260°C
% at +25°C mΩ at +25°C
mA at
120 Hz
100 kHz
+25°C 100
Max
Max
kHz
6
6,000
112
6
3500
156
6
3,500
156
6
3,500
156
6
3,500
156
6
1,800
247
6
3,000
168
6
1,800
247
6
1,800
247
6
800
433
6
1,200
303
8
800
433
8
700
463
6
8,000
97
6
8,000
97
6
6,000
112
6
6,000
112
6
3,500
156
6
6,000
112
6
3,500
156
6
3,500
156
6
1,800
247
6
3,500
156
6
1,800
247
6
3,000
168
6
1,800
247
6
1,800
247
6
1,600
306
6
800
433
6
800
433
8
700
463
8
500
574
4
10,000
87
97
6
8,000
6
6,000
112
6
6,000
112
6
3,500
156
6
6,000
119
6
7,000
104
6
3,500
156
6
1,800
247
6
3,500
156
6
1,800
247
6
1,800
247
6
1,600
262
6
800
433
6
800
433
% at +25°C mΩ at +25°C
mA at
120 Hz
100 kHz
+25°C 100
Max
Max
kHz
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum Allowable
Ripple Current (rms)
Maximum
Operating
Temp
MSL
(1) To complete KEMET part number, insert M for ±20% or K for ±10%. Designates Capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, G = Gold Plated, H = Standard Solder coated (SnPb 5% Pb minimum).
Designates Termination Finish.
Refer to Ordering Information for additional detail.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitution will be marked with
the higher voltage rating. Substitutions can include better than series.
[font=微软雅黑][size=3]Following [url=https://www.eeworld.com.cn/training/2014/TI_power_0213/383.html]《Switching Power Supply Design: PCB Thermal Management》[/url], Daxuetang has launched another practica...
Abstract: By improving the traditional clutch control system, the mechanical manual operation process is completed by the electronically controlled hydraulic system to realize the automatic control of...
[align=left]Many friends are confused about the viewing distance and monitoring angle of different lenses of surveillance cameras. The figure below clearly expresses the monitoring angle and monitorin...
Google's driverless technology is not only an eye-catching technology, but also a subversion of the car usage model.
Those who have watched anti-terrorism films and TV dramas must have been im...[Details]
There are three types of mobile TV: one is based on analog TV broadcasting network, another is based on mobile communication network, and the other is based on digital broadcasting network. The f...[Details]
Overview
As a remote network communication control method with advanced technology, high reliability, complete functions and reasonable cost, CAN-bus has been widely used in various automa...[Details]
1 Introduction
Intelligent control instruments are one of the most commonly used controllers in industrial control. They are mainly aimed at a specific parameter (such as pressure, tempera...[Details]
Toyohashi University of Technology demonstrated electric field coupled wireless power supply technology using life-size car tires and roads at the wireless technology exhibition "Wireless Technolog...[Details]
Capacitors
are basic components in various electronic devices and are widely used for bypassing, coupling,
filtering
, tuning, etc. in electronic circuits. However, to use capacitors,...[Details]
1. When the slip speed regulating motor is undergoing frequency conversion and energy saving transformation, the original excitation box (referred to as the speed regulating box) and the original s...[Details]
With the widespread application of new services and technologies in the communications industry, the scale and capacity of operators' network construction are getting larger and larger, and the ris...[Details]
The future energy storage hotspot is not coal or iron ore, but lithium. This lightest metal in nature may be the heaviest resource in the future energy landscape. China launched an ambitious electr...[Details]
summary
This article will briefly analyze the success and shortcomings of high-frequency DC-DC switching power supplies in the process of miniaturization (the second basic goal), and propose m...[Details]
The installation locations of DC-DC converters are relatively scattered. DC-DC converters can be found on the power board, main board, logic control board and other circuit boards of PDP color TVs....[Details]
1 Introduction
The stepper motor is an actuator of an open-loop servo motion system, which is controlled in a pulse mode and outputs angular displacement. Compared with AC servo motors and DC servo ...[Details]
1. Introduction
Stepper motor is a basic component that converts electrical energy into kinetic energy. It has been widely used in a variety of electromechanical equipment, such as various machine...[Details]
1 Theoretical Analysis
Ultrasonic waves
When propagating in a suspension, the ultrasonic waves that encounter the suspended particles are scattered and attenuated at the interface, an...[Details]
The Challenge:
Improving Siemens Wind
Turbine Controls
System software automated testing for regular releases, validating wind turbine control system components during the developme...[Details]