Features
Regulated
Converter
Description
• 10:1 ultra wide input voltage range
• 4.242kVAC/1 minute reinforced insulation
• UL/IEC/EN60950-1 certified
• CE marked, CB report
• Efficiency up to 93%
• -40°C to +93.5°C baseplate temperature range
DC/DC Converter
RPA200H-RUW
200 Watt
Half Brick
Single Output
The half-brick RPA200H series DC/DC converter is designed for railway rolling stock and high voltage
battery applications. It has a 10:1 input voltage range to cover all input voltages from nominal 24VDC up
to 110VDC in a single product (including EN50155 transients) and offers isolated and regulated
12V, 15V, 24V or 48VDC outputs. The converter has a consistently high efficiency over the entire
input voltage range and comes with a metal baseplate to permit a wide operating temperature range
from -40°C to +93.5°C (when baseplate cooled). The case is fitted with threaded inserts to allow
secure mounting to the PCB or bulkhead for use in high shock and vibration environments.
The converter is certified to UL/IEC/EN60950 and comes with a three year warranty.
Selection Guide
Part Number
Input
Voltage Range
(1)
[VDC]
16.5-140
16.5-140
16.5-140
16.5-140
Output
Voltage
[VDC]
12
15
24
48
Output
Current
[A]
16.7
13.5
8.5
4.2
Efficiency
typ.
(2)
[%]
90
93
88
90
Max. Capacitive
Load
(3)
[µF]
2200
2200
1000
100
RPA200H-11012SRUW
(4)
RPA200H-11015SRUW
(4)
RPA200H-11024SRUW
(4)
RPA200H-11048SRUW
(4)
Notes:
Note1: Refer to input voltage graph on page PB-3
Note2: Efficiency is tested at nominal input (110V) and full load at +25°C ambient
Note3: Max. Cap Load is tested at nominal input and full resistive load
E224736
UL60950-1 certified
CAN/CSA No. 60950-1-07
IEC/EN60950-1 certified
EN50155 compliant
CB report
Model Numbering
RPA200H-__ __ SRUW/_
Input Voltage
Output Voltage
Single
Ordering Examples
RPA200H-11012SRUW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RPA200H-11012SRUW/N = 110V Input, 12V Output, Single, Neg. CTRL function
Notes:
Note4: add suffix “P” for positive logic (1=ON, 0=OFF) or add
suffix “N” instead for negative logic (0=ON, 1=OFF)
CTRL Logic
(4)
Railway Ultra Wide Input
Specifications
(measured
Parameter
Internal Input Filter
Input Voltage Range
Input Surge Voltage
Under Voltage Lockout (UVLO)
(5)
Over Voltage Lockout (OVLO)
Input Current Range
@ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Condition
Min.
16.5VDC
<1s
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Vin = 16.5V
12, 15Vout
24, 48Vout
15.6VDC
13.6VDC
142VDC
154VDC
13.5A
14A
16.0VDC
14.0VDC
146VDC
156VDC
14A
14.5A
Typ.
110VDC
Max.
Pi-Type
140VDC
156VDC
16.4VDC
14.4VDC
150VDC
160VDC
14.5A
15A
Notes:
Note5: please refer to Under Voltage Lockout Adjustability on page PB-3
continued on next page
www.recom-power.com
REV.: 2/2018
https://www.recom-power.com/pdf/
Powerline_DC-DC/RSPxxx-168.pdf
PB-1
RPA200H-RUW
DC/DC Converter
Specifications
(measured
Parameter
Quiescent Current
Output Voltage Trimming
Minimum Load
Start-up time
Rise Time
Positive Logic
ON/OFF Control
(6)
Negative Logic
Input Current of CTRL pin
Standby Current
Internal Operating Frequency
Output Ripple and Noise
Remote Sense
(6)
Notes:
Note6: see page PB-5
20MHz BW limited
DC-DC ON
DC-DC OFF
Vout from 10% to 90%
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Vin = 110V
@ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
Series
Condition
12, 15, 24Vout
48Vout
BASIC CHARACTERISTICS
Min.
30mA
50mA
-20%
0%
200ms
50ms
460ms
100ms
Open or 3 < Vr < 5VDC
Short or 0 < Vr < 0.4VDC
Short or 0 < Vr < 0.4VDC
Open or 3 < Vr < 5VDC
0.1mA
0.2mA
0.1mA
0.2mA
20mA
140kHz
350mVp-p
±10%
Typ.
60mA
80mA
Max.
90mA
150mA
+10%
RPA200H-11012SRUW
100
90
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
16.5V
24V
36V
48V
72V
110V
140V
90
100
80
Efficiency vs. Output Current
Power Dissipation vs. Output Current
40
35
16.5V
24V
36V
48V
72V
110V
140V
Dissipated Power [W]
30
25
20
15
10
5
0
0
Efficiency [%]
4
8
12
16 16.7
Output Current [%]
Output Current [A]
RPA200H-11015SRUW
Efficiency vs. Output Current
100
90
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
16.5V
24V
36V
48V
72V
110V
140V
90
100
80
30
25
Power Dissipation vs. Output Current
16.5V
24V
36V
48V
72V
110V
140V
Dissipated Power [W]
Efficiency [%]
20
15
10
5
0
0
4
8
12
13.5
Output Current [%]
Output Current [A]
continued on next page
www.recom-power.com
REV.: 2/2018
PB-2
RPA200H-RUW
DC/DC Converter
Specifications
(measured
@ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
Series
Power Dissipation vs. Output Current
40
35
16.5V
24V
36V
48V
72V
110V
140V
RPA200H-11024SRUW
Efficiency vs. Output Current
100
90
80
Dissipated Power [W]
100
Efficiency [%]
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
16.5V
24V
36V
48V
72V
110V
140V
90
30
25
20
15
10
5
0
0
2
4
6
8 8.5
Output Current [%]
Output Current [A]
RPA200H-11048SRUW
Efficiency vs. Output Current
100
90
80
Power Dissipation vs. Output Current
40
35
16.5V
24V
36V
48V
72V
110V
140V
Dissipated Power [W]
100
Efficiency [%]
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
16.5V
24V
36V
48V
72V
110V
140V
90
30
25
20
15
10
5
0
0
Output Current [%]
1
Output Current [A]
2
3
4 4.2
Input Voltage Range
Output Power [%]
100
Continuous full power operation is rated between 16.5V and 140V,
including full load start-up.
Once running, the converter will operate for short periods of time over
an extended input voltage range down to 14.4V and up to 156V, thus
covering all EN50155 under-voltage and over-voltage transient
conditions.
0.1s
continuous operation
1s
0
14.4
16.5
140
Input Voltage [VDC]
156
UNDER VOLTAGE LOCKOUT ADJUSTABILITY
+Vin
UVLO
R1
-Vin
-Vout
+Vout
The RPA200H series has an adjustable under voltage lockout which will shut down the
converter according to following settings.
Nom. Input Voltage [VDC]
Turn Off Threshold [VDC]
Turn On Threshold [VDC]
Resistor R1 [kΩ]
24
14±0.4V
16±0.4V
open
36
20.6±1V
24±1V
24.9
48
27.5±1V
32±1V
12.4
72
40±1V
46.5±1V
6.19
110
64±2V
74±2V
3.48
www.recom-power.com
Hold Up Circuit
Ext. Cap.
+Vout
REV.: 2/2018
PB-3
RPA200H-RUW
DC/DC Converter
Specifications
(measured
@ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
Series
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
RPA200H-RUW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage
may slightly vary; they also can be calculated with below shown equation.
Trim Calculation
Vout = nom. Output Voltage
DVout
= Output Voltage Change in %
R
up
= trim up resistor
R
down
= trim down resistor
Trim up
12Vout
TRIM UP
TRIM
R
1
+Sense
TRIM
-Sense
TRIM DOWN
R
2
R
up
=
15Vout
45
DVout
24Vout
+ 40
kΩ
R
up
=
48Vout
95
DVout
+ 90
kΩ
Practical Example
Trim Up:
Vout = 12V,
DVout
= +10% (13.2V)
Rup =
45
10%
+ 40 kΩ = 490kΩ (E96 = 487)
R
up
=
57.46
DVout
+ 52.35
kΩ
R
up
=
195
DVout
+ 190
kΩ
Trim down
Trim down:
Vout = 24V,
DVout
= -8% (22V)
Rdown =
5.11
8%
- 10.22 kΩ = 53.66kΩ (E96 = 53.6)
R
down
=
5.11
DVout
- 10.22
kΩ
Trim up
RPA200H-11012SRUW
Trim up
Vout =
R
1
=
[%]
[VDC]
[k
Ω
]
1
12.12
4530
2
12.24
2320
3
12.36
1540
4
12.48
1150
5
12.60
931
6
12.72
787
7
12.84
681
8
12.96
604
9
13.08
536
10
13.20
487
RPA200H-11015SRUW
Trim up
Vout =
R
1
=
[%]
[VDC]
[k
Ω
]
1
15.15
5760
2
15.30
2940
3
15.45
1960
4
15.60
1500
5
15.75
1210
6
15.90
1010
7
16.05
866
8
16.20
768
9
16.35
681
10
16.50
619
RPA200H-11024SRUW
Trim up
Vout =
R
1
=
[%]
[VDC]
[k
Ω
]
1
24.24
9530
2
24.48
4870
3
24.72
3240
4
24.96
2490
5
25.20
2000
6
25.44
1690
7
25.68
1430
8
25.92
1270
9
26.16
1150
10
26.40
1050
RPA200H-11048SRUW
Trim up
Vout =
R
1
=
[%]
[VDC]
[k
Ω
]
1
48.48
19600
2
48.96
9880
3
49.44
6650
4
49.92
5110
5
50.40
4120
6
50.88
3480
7
51.36
3010
8
51.84
2610
9
52.32
2370
10
52.80
2150
Trim down RPA200H series
Trim down
R
2
=
Trim down
R
2
=
[%]
[k
Ω
]
[%]
[k
Ω
]
1
499
11
36.5
2
243
12
32.4
3
162
13
28.7
4
118
14
26.1
5
90.9
15
23.7
REV.: 2/2018
6
75
16
22.1
7
63.4
17
20
8
53.6
18
18.2
9
46.4
19
16.5
10
41.2
20
15.4
PB-4
www.recom-power.com
+Vin
+Vout
DC/DC Converter
+Vin
Specifications
UVLO
RPA200H-RUW
Series
EXTERNAL CAPACITOR
R1
-Vin
Hold Up Circuit
D1
Hold Up Circuit
D1
C1
R1
R1
+Vout
R1
(measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
UVLO
-Vout
-Vin
-Vout
+Vout
Ext. Cap.
C2
+Vout
A 240µF/200V capacitor (C2) is required for normal operation.
To meet power supply interruptions, an external circuit comprised of a capacitor (C1),
a 100Ω/10W resistor (R1) and diode (D1) is required.
C1
24Vin
3600µF
36Vin
3600µF
48Vin
3600µF
72Vin
3600µF
96Vin
1000µF
3000µF
110Vin
600µF
1800µF
Ext. Cap.
C2
-Vin
-Vout
For 10ms
For 30ms
10800µF 10800µF 10800µF 10800µF
C1
-Vin
-Vout
ON/OFF CONTROL
+Vin
+Vout
R1
+Vin CTRL
Q1
C1
+Vout
-Vout
For negative logic, if the remote on/off feature is not used, short the on/off pin to -Vin.
For positive logic, if the remote on/off feature is not used, leave the on/off pin floating.
R1
C1
CTRL -Vin
Q1
-Vout
-Vin
REMOTE SENSE
+Vin
+Vout
+Sense
R1
Load
Trim
R2
-Sense
-Vin
-Vout
(GND)
RW2
RW1
The output voltage can be adjusted by both trim and remote sense. The
maximum combined adjustment range is ±10%. Derate the maximum
output power if using the trim or sense function to increase the output
voltage.
RW1 ... wire losses +
RW2 ... wire losses -
R1 ... trim up resistor
R2 ... trim down resistor
REGULATION
Parameter
Output Accuracy
Line Regulation
Load Regulation
Vin = 16.5 to 140V, Io = full load
10 - 90% load
12Vout
Transient Response
25% load step change
15Vout
24Vout
48Vout
continued on next page
www.recom-power.com
REV.: 2/2018
PB-5
Condition
Value
±1.0% max.
±0.01% typ. to ±0.2% max.
0.05% typ. to 0.2% max.
450mV/40µs typ.
450mV/30µs typ.
500mV/20µs typ.
600mV/10µs typ.