EEWORLDEEWORLDEEWORLD

Part Number

Search

TBJD475K050CBLC9000

Description
tantalum capacitors - solid smd 50volts 4.7uf 10% case D
CategoryPassive components   
File Size200KB,7 Pages
ManufacturerAVX
Environmental Compliance
Download Datasheet Parametric View All

TBJD475K050CBLC9000 Overview

tantalum capacitors - solid smd 50volts 4.7uf 10% case D

TBJD475K050CBLC9000 Parametric

Parameter NameAttribute value
ManufactureAVX
Product CategoryTantalum Capacitors - Solid SMD
RoHSYes
Capacitance4.7 uF
Voltage Rating50 V
Tolerance10 %
Case Code - i2917
Case Code - mm7343
Heigh3.1 mm
Mfr Case CodeD Case
Operating Temperature Range- 55 C to + 125 C
Case Length7.3 mm
Case Width4.3 mm
Package / Case2917 (7343 metric)
PackagingBulk
ProducTantalum Solid High Reliability
Factory Pack Quantity200
Termination StyleSMD/SMT
TBJ Series
COTS-Plus – SRC9000 Space Level
The TBJ COTS-Plus –SRC9000 series has
been refined to incorporate only those com-
mercially up-screened ratings which have been
deemed suitable for mission critical and space
level applications.
These capacitors have a more conservative
design approach when compared to other up-
screened components utilizing established CV
powders and higher dielectric formation ratios.
The DCL is typically 25% lower while still offer-
ing aggressive ESR values.
Currently there are 5 case sizes available with a
6th in development to expand the maximum
capacitance available in a given voltage range.
These ratings are available with Weibull grad-
ing (B and C), surge current testing MIL-PRF-
55365 Rev. G (A, B, C), optional Group A from
MIL-PRF-55365, and the extensive SRC9000
space level screening.
The TBJ “E” and “U” case size components
are considered to be MSL 3 in accordance
with J-STD-020.
CASE DIMENSIONS:
millimeters (inches)
Code
A
L
W
EIA
Code
1206
1210
2312
2917
2917
2924
EIA
Metric
3216-18
3528-21
6032-28
7343-31
7343-43
7361-43
L±0.20
(0.008)
3.20 (0.126)
3.50 (0.138)
6.00 (0.236)
7.30 (0.287)
7.30 (0.287)
7.30 (0.287)
W+0.20 (0.008)
-0.10 (0.004)
1.60 (0.063)
2.80 (0.110)
3.20 (0.126)
4.30 (0.169)
4.30 (0.169)
6.10 (0.240)
H+0.20 (0.008)
-0.10 (0.004)
1.60 (0.063)
1.90 (0.075)
2.60 (0.102)
2.90 (0.114)
4.10 (0.162)
4.10 (0.162)
W
1
±0.20
(0.008)
1.20 (0.047)
2.20 (0.087)
2.20 (0.087)
2.40 (0.094)
2.40 (0.094)
3.10 (0.120)
A+0.30 (0.012)
-0.20 (0.008)
0.80 (0.031)
0.80 (0.031)
1.30 (0.051)
1.30 (0.051)
1.30 (0.051)
1.30 (0.051)
S Min.
1.10 (0.043)
1.40 (0.055)
2.90 (0.114)
4.40 (0.173)
4.40 (0.173)
4.40 (0.173)
B
C
D
E
U
H
A
S
A
W
1
W
1
dimension applies to the termination width for A dimensional area only.
μF
Capacitance
Code
104
154
224
334
474
684
105
155
225
335
6.3V (J)
10V (A)
16V (C)
Rated Voltage DC (V
R
) to 85°C
20V (D)
25V (E)
35V (V)
A(20000)
A(6000, 16470)
A(6000, 13710)
A(6000, 11280)
A(4000, 9530)
A(6000, 8000)
A(3000, 6630)
B(2000, 3400)
A(2000, 3100)
B(2500, 5460)
B(2000, 4550)
B(1000, 3740)
C(800, 1840)
D(2000)
B(1500, 2200)
C(600, 1410)
D(1500)
C(600, 1070)
D(1300)
C(600, 800)
D(250, 800)
D(225, 720)
50V (T)
0.1
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
A(10000)
A(7000)
A(7000)
A(3500, 4550)
A(3500, 3750)
B(4500)
A(2000, 3160)
B(1500, 3160)
A(1500, 2000)
B(1200, 2650)
C(2500)
B(800, 2200)
C(2000)
B(800, 2000)
B(600, 1100)
C(350, 700)
D(1100)
C(300, 590)
C(350, 540)
D(200, 340)
D(150, 490)
D(150, 450)
E(150, 450)
E(150, 300)
U(200,500)
A(3000, 6630)
A(3000, 5640)
A(3000, 4550)
A(2500, 3750)
B(1300, 3740)
A(1800, 2500)
B(1000, 3160)
B(1000, 2650)
C(2000)
B(1000, 2200)
C(500, 800)
B(500, 1400)
C(400, 750)
D(1100)
C(400, 650)
D(150, 650)
C(300, 590)
D(250, 590)
D(200, 540)
D(200, 490)
E(125, 490)
E(150, 300)
U
A(7000, 9530)
A(6000, 7980)
A(3000, 6630)
A(3000, 5640)
B(5000)
A(1600, 2900)
B(1200, 4550)
B(2000, 3740)
A(7000, 7500)
A(7000)
B(5000)
B(2000, 4000)
B(2000, 3400)
C(3000)
C(1500, 2500)
C(1000, 1700)
D(1200, 2000)
C(1000, 1400)
D(800, 1100)
4.7
475
A(2000, 2900)
A(1800, 4000)
B(3000)
A(1500, 2000)
B(3000)
A(1500, 2030)
B(700, 2030)
A(900, 1700)
B(600, 1880)
C(2000)
B(600, 1740)
C(1800)
B(500, 1620)
C(250, 540)
C(200, 490)
C(300, 440)
C(300, 500)
D(150, 400)
D(150, 360)
D(400)
E(150, 330)
E(200, 250)
A(1800, 2200)
B(800, 2200)
A(1000, 1800)
B(600, 2030)
C(2000)
B(700, 1800)
B(650, 1000)
C(300, 590)
D(1100)
C(300, 540)
D(400)
C(300, 490)
C(200, 500)
D(150, 440)
E(100, 440)
D(150, 400)
E(150, 400)
D(500)
E(150, 360)
E(100, 300)
U
B(1000, 3160)
B(1000, 1500)
C(600, 1070)
C(600, 800)
D(1200)
C(500, 720)
D(300, 720)
D(300, 650)
D(600, 900)
6.8
10
15
685
106
156
D(700)
E(300, 700)
U
22
226
D(200, 650)
33
47
68
100
150
220
330
470
1000
336
476
686
107
157
227
337
477
108
D(400, 590)
D(250, 540)
E(150, 540)
U
E(250, 590)
U(200,400)
Available Ratings: ESR limits quoted in brackets (mOhms)
Engineering samples - please contact manufacturer
*Codes under development - subject to change.
Notes: Voltage ratings are minimum values. AVX reserves the right to supply
higher ratings in the same case size, to the same reliability standards.
APRIL 2014
41
EEWORLD University Hall----Circuit (Jiangsu University)
Circuits (Jiangsu University) : https://training.eeworld.com.cn/course/2728701 Circuits and circuit models02Reference directions of current and voltage03Electric power and energy04Resistor05Voltage so...
JFET Analog electronics
【Show Classics】Home Appliances - Table Lamp
[i=s]This post was last edited by dontium on 2015-1-23 13:23[/i]1. USB desk lamp The circuit diagram of the USB desk lamp is shown below. To avoid possible electromagnetic radiation, the power supply ...
常见泽1 Analogue and Mixed Signal
(Reply points) Compilation issues under arm and x86 platforms (simulators)
I downloaded a game code from the Internet, and it compiled fine under the ARM SDK, but when I compiled it under the x86 platform (emulator) SDK, a lot of problems occurred. First, it said that the he...
redworlf ARM Technology
【October DIY】Postscript on Routing Change
Following the previous router, if it fails to boot successfully, it is not considered as a complete DIY, so I quickly did another wave of DIY. This time, for the RAM, after much thought, I decided to ...
sjtitr Integrated technical exchanges
Fire host transmission equipment
I am working on a smart fire protection platform. I upload the alarm information of the fire host to the platform through a transmission device. But I don't know how to read the data of the fire host ...
qrnuyangfu Test/Measurement
Why is there voltage output when the MOS tube is not conducting?
Why is the voltage at the out end always around 4.5V~5V when the optocoupler is not conducting? Is it leakage current? Is it that much? Because a 10K resistor is connected to the LED in series at the ...
sky999 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 356  2847  1369  1757  828  8  58  28  36  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号