AC-DC Power Factor Correction Module, 2 Output, 150W, Hybrid, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size994KB,28 Pages
ManufacturerBel Power Solutions
Download Datasheet Parametric View All

LK5660-7EPD2TB1 Overview

AC-DC Power Factor Correction Module, 2 Output, 150W, Hybrid, METAL, CASE K02, MODULE

LK5660-7EPD2TB1 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Objectid1511272318
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage48.28 V
Minimum output voltage47.72 V
Nominal output voltage48 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputNO
Cassette Style
AC-DC Converters
S Series PFC
150 Watt AC-DC Converters with PFC
Input voltage range from 85...255 V AC
1or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
K-Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K 4000/5000-series of AC-DC converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified ranges. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected with pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19 inch rack sys-
tems according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the
LK 1000 and LK 2000 in order to comply with IEC/EN
61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 16
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 28
1/28
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 12
Edition 5/5.2000
how so
[i=s]This post was last edited by paulhyde on 2014-9-15 09:17[/i] No one from our school won a national award this year. I am so depressed!...
天涯逐日 Electronics Design Contest
Does static electricity belong to the security industry?
I want to know, does electrostatic protection belong to the security industry? Our company makes anti-static products, but I don't know what industry it belongs to....
yimeng1988 Industrial Control Electronics
The story of the working principle of the triode
Back then, I was also confused about the working principle of the triode. I thought about it for a long time and hope it will be useful to you. To understand the amplification effect of the triode, re...
linda_xia Analog electronics
Basic knowledge: understand the difference between VCC, VDD and VSS
[i=s]This post was last edited by qwqwqw2088 on 2014-9-1 19:56[/i] [p=24, 2, left][color=rgb(62, 62, 62)][font=Tahoma, Arial, sans-serif]In electronic circuits, we often see three different symbols: [...
qwqwqw2088 Analogue and Mixed Signal
LED dot matrix microcontroller 2048 game
This is my graduation project. I think the experts who have seen the keywords know what I am going to do. I am a newbie, but I am willing to ask for advice sincerely. I hope that the experts who are i...
hellton 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2020  1272  17  1130  953  41  26  1  23  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号