Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature ......................................................+150°C
Storage Temperature Range ...............................-65°C to 150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(V
IN
= +2.7V or V
OUT(NOM)
+ 0.5V (whichever is greater),
SHDN
= IN, SS = open, SET = GND, C
OUT
= 1µF,
T
A
= 0°C to +85°C,
unless otherwise noted. Typical values are at T
A
= +25°C.)
PARAMETER
Input Voltage Range
Input Undervoltage Lockout
Output Voltage Accuracy
SET Regulation Voltage
(Adjustable Mode)
Line Regulation
Load Regulation
Adjustable Output Voltage Range
Maximum Output Current
Short-Circuit Current Limit
In-Regulation Current Limit
SET Dual Mode Threshold
SET Input Bias Current
Ground Current
Dropout Voltage
(Note 1)
Output Voltage Noise
Power-Supply Rejection Ratio
Shutdown Supply Current
SHDN
Input Threshold
SHDN
Input Bias Current
Soft-Start Charge Current
RST
Output Low Voltage
IN Operating Voltage Range for
RST
Valid
RST
Leakage
RST
Trip Level Referred to
Nominal V
OUT
RST
Release Delay
Thermal Shutdown Threshold
2
SYMBOL
V
IN
CONDITIONS
Typical hysteresis = 50mV
I
OUT
= 1mA, T
A
= +85°C
I
OUT
= 150mA, T
A
= +85°C
MIN
2.7
2.35
-1
792
TYP
2.45
MAX
5.5
2.55
1
UNITS
V
V
%
mV
%/V
800
0.1
0.8
808
∆V
LNR
∆V
LDR
I
OUT
I
LIM
I
LIM
I
SET
I
GND
V
IN
= V
OUT
+ 0.5V to +5.5V, I
OUT
= 10mA
I
OUT
= 1mA to 1A
0.8
Continuous
V
OUT
= 0V
V
SET
= 0.76V
V
SET
= +0.9V
I
OUT
= 100µA
I
OUT
= 1A
I
OUT
= 1mA, +2.7V < V
IN
< +5.5V
I
OUT
= 1A, V
OUT
= +3.3V (Note 2)
f = 10Hz to 1MHz, C
OUT
= 1µF, I
OUT
= 150mA
1
1.0
2.0
40
1.5
5
%/A
V
A
RMS
A
A
1.9
4.0
80
50
0.5
2.5
0.2
200
150
54
0.1
10
0.6
0
6
0.1
0.1
350
120
300
2.0
mV
nA
mA
mV
µV
RMS
dB
µA
V
µA
µA
V
V
µA
% OUT
ms
o
PSRR
I
OFF
V
IH
V
IL
I
SS
f = 100kHz, C
OUT
= 1µF
SHDN
= GND, V
IN
= +5.5V, V
OUT
= 0
+2.7V < V
IN
< +5.5V
SHDN
= GND or IN
V
SS
= 0V
I
SINK
= 1mA
I
SINK
= 10µA
V
RST
= +5.5V
Falling edge, typical hysteresis = 10mV
Rising edge
89
1
1.0
1.6
5.5
0.01
92
3
+170
1
95
5.5
T
SHDN
Typical thermal hysteresis = +20°C
C
Dual Mode is a trademark of Maxim Integrated Products.
Maxim Integrated
MAX8869
1A, Microcap, Low-Dropout,
Linear Regulator
ELECTRICAL CHARACTERISTICS
(V
IN
= +2.7V or V
OUT(NOM)
+ 0.5V (whichever is greater),
SHDN
= IN, SS = open, SET = GND, C
OUT
= 1µF,
T
A
= -40°C to +85°C,
unless otherwise noted.) (Note 3)
PARAMETER
Input Voltage Range
Input Undervoltage Lockout
Output Voltage Accuracy
SET Regulation Voltage
(Adjustable Mode)
Load Regulation
Adjustable Output Voltage Range
Maximum Output Current
Short-Circuit Current Limit
In-Regulation Current Limit
SET Dual Mode Threshold
SET Input Bias Current
Ground Current
Dropout Voltage (Note 1)
Shutdown Supply Current
SHDN
Input Threshold
SHDN
Input Bias Current
RST
Output Low Voltage
IN Operating Voltage Range for
RST
Valid
RST
Leakage
RST
Trip Level Referred to
Nominal V
OUT
RST
Release Delay
I
OFF
V
IH
V
IL
I
SET
I
GND
V
SET
= +0.9V
I
OUT
= 100µA
I
OUT
= 1A, V
OUT
= +3.3V (Note 2)
SHDN
= GND, V
IN
= +5.5V, V
OUT
= 0V
+2.7V < V
IN
< +5.5V
SHDN
= GND or IN
I
SINK
= 1mA
I
SINK
= 10µA
V
RST
= +5.5V
Falling edge, typical hysteresis = 10mV
Rising edge
88
1
1.0
1.7
0.6
0.1
0.1
5.5
1
95
6
I
OUT
I
LIM
I
LIM
Continuous
V
OUT
= 0V
V
SET
= +0.76V
∆V
LDR
SYMBOL
V
IN
Typical hysteresis = 50mV
I
OUT
= 1mA, T
A
= +85°C
I
OUT
= 150mA, T
A
= +85°C
I
OUT
= 1mA to 1A
0.8
1
1.0
2.0
40
120
300
2.0
350
10
CONDITIONS
MIN
2.7
2.3
-1
792
MAX
5.5
2.6
1
808
2.0
5
UNITS
V
V
%
mV
%/A
V
A
RMS
A
A
mV
nA
mA
mV
µA
V
µA
V
V
µA
% OUT
ms
Note 1:
Dropout voltage is (V
IN
- V
OUT
) when V
OUT
falls to 100mV below the value of V
OUT
measured when V
IN
= V
OUT(NOM)
+0.5V.
Since the minimum input voltage is 2.7V, this specification is only meaningful when V
OUT
≥
2.7V.
Note 2:
The output voltage is externally set using a resistive voltage-divider from OUT to SET.
Note 3:
Specifications to -40°C are guaranteed by design, not production tested.