industrial & electrical fuses 600v 35a dual elemtent time delay
CategoryCircuit protection   
File Size364KB,2 Pages
ManufacturerBussmann (Eaton)
Download Datasheet Parametric Compare View All

FRS-R-35 Online Shopping

Suppliers Part Number Price MOQ In stock  
FRS-R-35 - - View Buy Now

FRS-R-35 Overview

industrial & electrical fuses 600v 35a dual elemtent time delay

FRS-R-35 Parametric

Parameter NameAttribute value
ManufactureCooper Bussm
Product CategoryIndustrial & Electrical Fuses
RoHSN
Body StyleCartridge Fuses
Current Rating35 A
Voltage Rating AC600 V
Mounting StyleHolde
Termination StyleCli
Fuse TypeTime Delay / Slow Blow
Fuse Size / GrouClass RK5
Indicator StyleWithout Indic
Dimensions5.5 in L x 1.06 in D
Case Diamete1.06 i
Case Length5.5 i
Interrupt Rating200 kA
PackagingBulk
ProducIndustrial Power Fuses
Factory Pack Quantity10
TypeDual Element Time Delay Fuse
Unit Weigh136.078 g
F
USETRON
Energy Efficient
Dual-Element, Time-Delay Fuses
Class RK5 – 600 Volt
Dimensions - in
5" (± 0.031)
.81" (± 0.008)
⁄/¡ºA
to 30A
FRS-R
1
10
-60A
5.5" (± 0.31)
1.06" (± 0.008)
35A to 60A
Catalog Symbol:
FRS-R
Current-limiting
Dual-element, time-delay – 10 second (minimum) at 500%
rated current
Ratings:
Volts – 600Vac (or less)
Amps –
1
10
-30A
IR – 200kA RMS Sym.
– 20kA @300Vdc
Amps – 35-60A
IR – 200kA RMS Sym.
– 20kA @250Vdc
Agency Information:
CE, UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787
Catalog Numbers
FRS-R-
1
10
FRS-R-
1
8
FRS-R- ⁄
100
15
2
1
General Information:
• Provides motor overload, ground fault and short-circuit
protection. When used in circuits subject to surge currents
such as those caused by motors, transformers and other
inductive components, these fuses can be sized close to
full-load amps to give maximum overcurrent protection.
• Permits the use of smaller and less costly switches. The
time-delay feature makes it possible to use fuse amp ratings
which are much smaller than those of non-time-delay fuses.
Considerable cost saving occurs by permitting the use of
smaller size switches, panels and fuses themselves.
• Provides a higher degree of short-circuit protection (greater
current-limitation) in circuits in which surge currents or
temporary overloads occur.
• Helps protect motors against burnout from overloads.
• Gives motor running back-up protection to motors without
extra costs.
• Helps protect motors against burnout from single phasing on
three phase systems.
• Simplifies and improves blackout prevention (selective
coordination).
• Dual-element fuses can be applied in circuits subject to
temporary motor overloads and surge currents to provide
both high-performance, short-circuit and overload protection.
• The overload element provides protection against low level
overcurrent of overloads and will hold an overload which is
five times greater than the amp rating of the fuse for a
minimum of ten seconds.
Carton Quantity and Weight
FRS-R-1
8
10
FRS-R-2
FRS-R-2 ⁄
4
1
1
8
FRS-R-8
FRS-R-9
FRS-R-10
FRS-R-12
FRS-R-15
FRS-R-17
1
2
FRS-R-20
FRS-R-25
FRS-R-30
FRS-R-35
FRS-R-40
FRS-R-45
FRS-R-50
FRS-R-60
Amp
Ratings
1
Carton
Qty.
10
10
10
Weight*
Lbs.
0.40
0.50
3.10
Kg.
0.181
0.277
1.406
10
–15
1
FRS-R- ⁄
10
FRS-R- ⁄
4
FRS-R-
3
10
FRS-R-
4
10
FRS-R- ⁄
2
1
6
8
FRS-R-2 ⁄
2
FRS-R-2 ⁄
10
FRS-R-3
FRS-R-3
2
10
FRS-R-3
1
2
FRS-R-4
FRS-R-4 ⁄
2
1
17 ⁄
2
–30
35-60
*Weight per carton.
Fuse Reducers For Class R Fuses
Equipment
Fuse Clips
60A
100A
200A
Desired
Fuse (Case)
Size
30A
30A
60A
60A
Catalog Number
(Pairs)
600V
No. 663-R
No. 216-R
No. 616-R
No. 626-R
FRS-R- ⁄
10
FRS-R- ⁄
10
FRS-R-1
FRS-R-1 ⁄
8
1
FRS-R-5
FRS-R-5 ⁄
10
6
FRS-R-1
1
4
FRS-R-1 ⁄
10
4
FRS-R-6
FRS-R-6 ⁄
4
1
FRS-R-1
1
2
FRS-R-1
6
10
FRS-R-7
FRS-R-7
1
2
Recommended fuseblocks for
Class R 600V fuses
See Data Sheet: 1111
1111
BU-SB11279
Page 1 of 2
Data Sheet 1017

FRS-R-35 Related Products

FRS-R-35 FRS-R-3-1/2 FRS-R-8 FRS-R-10 FRS-R-7 FRS-R-30 FRS-R-5 FRS-R-2 FRS-R-45
Description industrial & electrical fuses 600v 35a dual elemtent time delay industrial & electrical fuses 600v 3.5A dual elemtent time delay industrial & electrical fuses 600v 8A dual elemtent time delay industrial & electrical fuses 600v 10a dual elemtent time delay industrial & electrical fuses 600v 7A dual elemtent time delay industrial & electrical fuses 600v 30a dual elemtent time delay industrial & electrical fuses 600v 5A dual elemtent time delay industrial & electrical fuses 600v 2A dual elemtent time delay industrial & electrical fuses 600v 45a dual elemtent time delay
Manufacture Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm
Product Category Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses
RoHS N N N N N N N N N
Body Style Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses
Current Rating 35 A 3.5 A 8 A 10 A 7 A 30 A 5 A 2 A 45 A
Voltage Rating AC 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V
Mounting Style Holde Holde Holde Holde Holde Holde Holde Holde Holde
Termination Style Cli Cli Cli Cli Cli Cli Cli Cli Cli
Fuse Type Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow
Fuse Size / Grou Class RK5 Class RK5 Class RK5 Class RK5 Class RK5 Class RK5 Class RK5 Class RK5 Class RK5
Indicator Style Without Indic Without Indic Without Indic Without Indic Without Indic Without Indic Without Indic Without Indic Without Indic
Dimensions 5.5 in L x 1.06 in D 5 in L x 0.81 in D 5 in L x 0.81 in D 5 in L x 0.81 in D 5 in L x 0.81 in D 5 in L x 0.81 in D 5 in L x 0.81 in D 5 in L x 0.81 in D 5.5 in L x 1.06 in D
Case Diamete 1.06 i 0.81 i 0.81 i 0.81 i 0.81 i 0.81 i 0.81 i 0.81 i 1.06 i
Case Length 5.5 i 5 i 5 i 5 i 5 i 5 i 5 i 5 i 5.5 i
Interrupt Rating 200 kA 200 kA 200 kA 200 kA 200 kA 200 kA 200 kA 200 kA 200 kA
Packaging Bulk Bulk Bulk Bulk Bulk Bulk Bulk Bulk Bulk
Produc Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses
Type Dual Element Time Delay Fuse Dual Element Time Delay Fuse General Dual Element Time Delay Fuse General Dual Element Time Delay Fuse General General General
Unit Weigh 136.078 g 61.235 g 68.039 g 77.111 g 45.359 g 68.039 g 63.503 g 68.039 g 136.078 g
Factory Pack Quantity 10 - 10 10 10 10 10 10 10
Problems with debugging STM32 with keil. Need help! ! ! ! !
Hey guys, I use KEIL 5 to debug STM32. Question 1. I want to see the delay time of the delay function, but I find that if I set a breakpoint, the time it takes to run the function is 1S. If I don't se...
yanjianguo MCU
A very good wireless transmission module
[i=s]This post was last edited by paulhyde on 2014-9-15 09:10[/i] A very good wireless transmission module, worth learning! :) Including module introduction, interface circuit, module structure and pi...
cuizhihao Electronics Design Contest
Happy May Day to all forum friends, bring some fun to everyone
[font=文泉驿正黑][size=6][color=#4169e1]I was bored a while ago and disassembled a desktop computer monitor. However, I couldn't understand anything, but I was amazed by the superb technology of the design...
喵爱小鱼鱼 Integrated technical exchanges
Design of indoor sports assessment system
After the signal is successfully sent and received, it should be relatively easy to display the temperature and humidity in real time. However, it is a bit troublesome to draw the corresponding motion...
yueyuanque Wireless Connectivity
There are 169 holidays in 2017. Do you PCB design engineers believe it?
Original 169 days of holidays and rest days. Don’t say you don’t believe it. So I searched on the Internet. It is a certain fact that 26 days of statutory holidays, but where do the 169 days come from...
kdyhdl PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 428  1101  1119  1090  2300  9  23  22  47  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号