Standard Frequencies: 10, 12.8, 16.384, 19.44, 20, 20.48 MHz
•
•
•
•
Applications
PCS Base Stations
Land Mobile Radio
Cellular Telephoney
Radio in the Local Loop
Previous Vectron Model Numbers - C2260
Performance Specifications
Frequency Stabilities
1
Parameter
vs. operating temperature range
(referenced to +25°C)
Min
-1.5
-1.0
-2.5
-1.0
-1.0
-0.5
-2.5
-0.5
-0.2
-1.0
-0.80
-0.28
-0.28
-0.80
-0.28
-0.28
-1.0
-0.2
-0.1
-2.5
-4.6
Typical
Max
+1.5
+1.0
+2.5
+1.0
+1.0
+0.5
+2.5
+0.5
+0.2
+1.0
+0.80
+0.28
+0.28
+0.80
+0.28
+0.28
+1.0
+0.2
+0.1
+2.5
+4.6
Units
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
Condition
-40 to +85°C
-40 to +85°C
-20 to +70°C
-20 to +70°C
0 to +50°C
0 to +50°C
at time of shipment, nominal EFC
V
S
±5%
Load ±10%
after 30 days of operation
-20 to +70°C
0 to +50°C
-20 to +70°C
-40 to +85°C
-30 to +85°C
-40 to +85°C
Options
5
Options
5
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging / 1 Year
vs. operating temperature range
(referenced to +25°C)
Frequency Stabilities
1
(Stratum 3 TCXO) <32MHz
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging / 20 Years
Overall tolerance
at time of shipment, nominal EFC
V
S
±5% static
Load ±5% static
Note:*Stratum 3 per GR-1244-CORE:
<±4.6ppm for all causes and 20 years aging,
holdover: <±0.37ppm over 24 hours
Performance Specifications
Frequency Stabilities
1
Parameter
vs. operating temperature range
(referenced to +25°C)
For 10, 12.8, 16.384, 20.26 MHz
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging / 20 Years
Overall tolerance
Min
-0.15
Typical
Max
+0.15
Units
ppm
Condition
Options
5
@ 10MHz
Option
5
with Vs=3.3V
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
0 to +50°C
-1.0
-0.2
-0.1
-2.5
-4.6
+1.0
+0.2
+0.1
+2.5
+4.6
ppm
ppm
ppm
ppm
ppm
at time of shipment, nominal EFC
V
S
±5%
Load ±10%
Note:*Stratum 3 per GR-1244-CORE:
<±4.6ppm for all causes and 20 years aging,
holdover: <±0.37ppm over 24 hours
Supply Voltage (Vs)
Parameter
Supply voltage (standard)
Current consumption
Load R
|| C
Output Power
Load
Signal Level (Vol)
Signal Level (Voh)
Rise and Fall time
Duty Cycle
Tuning Range
Tuning Range for Stability: 807,
287, 157 / Stratum 3 Version
Tuning Range
Linearity
Tuning Slope
Control Voltage Range
Freq. control input impedance
0.3
10
True table
Pin 2
High
Open
Low
1.65
±5.0
±8.0
40
50
3.0
5
60
9
9
0.7
10
10
Min
3.135
Typical
3.3
Max
3.465
6
11
11
Units
VDC
mA
kΩ
pF
V
PP
Condition
steady state @ +25°C
RF Output (Clipped Sinewave)
@ 10kΩ || 10pF
RF Output (HCMOS)
13.5
15
16.5
0.3
pF
VDC
VDC
ns
%
@ (Voh-Vol)/2
with Vs=3.3V and 15pF Load
with Vs=3.3V and 15pF Load
Frequency Tuning (EFC)
Fixed TCXO; No adjust
±14.0
±14.0
10%
Positive
3.0
VDC
kΩ
±20.0
±20.0
ppm
ppm
Enable (instead of EFC)
RF_out
Pin 3
Data
Data
High Tristate
Additional Parameters
-65
-95
-120
-140
-145
8.0 g
Handling & Processing Note
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Phase Noise
3
Weight
Processing & Packing
Supply voltage (Vs)
Control Voltage
Operable Temperature Range
Storage Temperature Range
0
-40
-55
Absolute Maximum Ratings
6.0
Vs
+85
+125
V
V
°C
°C
Cross Reference List
Vectron Part Frequency Temp Range
(MHz)
(°C)
C2260A1-0028
C2260A1-0032
C2260A1-0029
C2260A1-0021
C2260A1-0009
C2260A1-0015
12.8
12.8
12.8
20
20
20
-20 to +70
-40 to +85
-40 to +85
-20 to +70
-20 to +80
-40 to +85
±0.28
±0.28
±4.6
Temp Stability
(ppm)
±0.28
±0.28
Holdover Stability
(ppm)
±0.37
±0.37
±4.60
Overal Stability
(ppm)
±4.6
±4.6
±20
±4.6
±4.6
±20
Supply
(V)
3.3
3.3
3.3
3.3
3.3
3.3
Semtech
Semtech
Semtech
Semtech
Semtech
Semtech
Standard Shipping Method
A
X
B
K
P
Enclosure Type
G204/G211
*bei W
≤ 24
mm
nur untere Lochreihe
∗by
W
≤
24 mm only lower hole line
Lage im Gurt
Position in tape
Pin 1
Abwickelrichtung
Unwinding direction
Gurtunterseite
Tape buttom side
Gurtoberseite
Tape upper side
Tape Width W (mm)
12
Quantity per meter
150.
Quantity per reel
750.
Dimension P
8
Standard Shipping Method
Package Codes: 700
Type
G204
Height “H”
2.5
Pin Length “L”
NA
Type
G204
Package Codes: 701
Height “H”
2.5
Pin Connections
1
2
3
4
Voltage Control (Vc) / Enable / N.C
Ground (Case)
RF Output
Supply Voltage Input (Vs)
Marking
TX-700
Frequency
AYYWW
Standard Shipping Method
Phase Noise
C2260 @ 12.8 MHz
MTIE according-1244-CORE:
C2260 @ 12.8 MHz
Recommended Reflow Profile
Profile Feature
Average ramp-up rate (T
L
to T
P
)
Preheat
-Temperature Min T
Smin
-Temperature Min T
Smax
-Time (min to max) t
S
Pb-Free Assembly/
Sn-Pb Assembly
3°C/second max.
150°C
200°C
60-180 seconds
3°C/second max
217°C
60-150 seconds
max 260°C
Profile Feature
Time 25°C to Peak Temperature
Time maintained above
-Temperature (T
L
)
-Time (t
L
)
Pb-Free Assembly/
Sn-Pb Assembly
8 minutes max.
217°C
60-150 seconds
TSmax to TL -Ramp-up Rate
Time maintained above
-Temperature (T
L
)
-Time (t
L
)
Peak Temperature (T
P
)
Time within 5°C of actual Peak
Temperature (t
P
)
Ramp-down Rate
20-40 seconds
6°C/ second max
Note:
All temperatures refer to topside of the package, measured on the package body surface.
Ordering Information
TX-70X 0 - E A J - 256 0 - 10M0000000
Model Code
700: Enclosure G204
701: Enclosure G211
Frequency
Frequency Control
0: No Tuning
1: ±5.0 to ±20ppm
2: ±8.0 to ±20ppm
3: Enable
Stability Code
256: ±2.5ppm
156: ±1.5ppm
106: ±1.0ppm
807: ±0.8ppm
507: ±0.5ppm
287: ±0.28ppm
157: ±0.15ppm
Height
0: 2.5mm
Supply Voltage
E: 3.3V
RF Output Code
A: HCMOS
F: Clipped Sinewave
Temperature Range
E: -40°C to +85°C
H: -30°C to +85°C
J: -20°C to +70°C
P: 0°C to +50°C
Notes:
1. Contact factory for improved stabilities or additional product options. Not all options and codes are available at all
frequencies.
2. Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency
control voltage, load, temperature (25°C).
3. Phase noise degrades with increasing output frequency.
4. Subject to technical modification.
5. Contact factory for availability.
For Additional Information, Please Contact
USA:
Vectron International
267 Lowell Road
Hudson, NH 03051
Tel: 1.888.328.7661
Fax: 1.888.329.8328
Europe:
Vectron International
Landstrasse, D-74924
Neckarbischofsheim, Germany
Tel: +49 (0) 7268.801.100
Fax: +49 (0) 7268.801.281
Asia:
Vectron International
1F-2F, No 8 Workshop, No 308 Fenju Road
WaiGaoQiao Free Trade Zone
Pudong, Shanghai, China 200131
Tel: 86.21.5048.0777
Fax: 86.21.5048.1881
Disclaimer
Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
[i=s]This post was last edited by le062 on 2015-3-5 18:09[/i] Previously, an event-driven example was run on the M0 core. However, on this MCU, the M0 core cannot run alone and must be started by the ...
Xi'an Antai Test Equipment Co., Ltd. is located in Xi'an High-tech Development Zone. It is a professional company focusing on instrument sales and system integration in the field of electronic testing...
[align=left][font=宋体]Questions about task stack calculation? Description is as follows: Environment: cortex M3 + ucos + IAR Create two tasks as follows. No local variables of APP are used in the tasks...
EEWORLD and ADI have jointly compiled the essence of "ADI Laboratory Circuits" into a book called "ADI Laboratory Circuits in the Module Era" ! We hope that through the power of electronic engineers o...
Traditional broadcasting systems generally need to be operated manually at a fixed time, and can only realize one-way broadcasting with few functions. Traditional bell ringing equipment has a singl...[Details]
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
1. Circuit composition
The whole circuit consists of two parts:
1. Power saving control circuit
As shown in the figure below. Including delay circuit and drive circuit.
(1) Delay ci...[Details]
1. Introduction
With the growth of parking demand, the scale of parking lots is becoming larger and larger. A lot of research has been done on intelligent parking lots in China, but most of th...[Details]
Converged processors meet scalability requirements
In current embedded system design, solutions based on MCU, DSP, FPGA and ASIC account for more than 90% of the market share. These solutions ...[Details]
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The way to reduce costs is
① Use the Bluetooth data transmission function of mobile ph...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
PV inverter manufacturer SMA has launched its first DC arc fault circuit interrupter (AFCI) PV inverter and has received UL certification.
The new SunnyBoy AFCI inverter models include 3000-US...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
Spatial Division Multiplexing (SDM) MIMO processing can significantly improve spectrum efficiency and thus greatly increase the capacity of wireless communication systems. Spatial Division Multip...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
LED light sources have many environmental advantages, but early products still have certain technical bottlenecks in heat dissipation and high brightness design that cannot be broken through....[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]