Isobar 12-Outlet Network Server Surge Protector, 15
ft. Cord w/5-20P Plug, 3840 Joules, Diagnostic
LEDs, 1U Rack-Mount
MODEL NUMBER:
IBAR12-20ULTRA
Highlights
2 NEMA 5-15R & 10 NEMA
5-20R outlets in isolated filter
banks
Network-grade 3840-joule surge
protection rating
Mounts into 1U of space in
EIA-standard 19 in. racks
20A resettable circuit breaker
prevents dangerous overloads
15 ft. AC power cord with NEMA
5-20P plug
Package Includes
IBAR12-20ULTRA Isobar
12-Outlet Surge Protector, 1U
Rack-Mount
Rack-mounting brackets
Owner’s manual
Description
Premium protection for essential network workstations, telecom systems, point-of-sale equipment and audio/video systems, the IBAR12-20ULTRA Isobar®
12-Outlet Surge Protector features a network-grade surge protection rating of 3840 joules to defend your sensitive electronics against even the strongest
surges and spikes. In fact, Tripp Lite will repair or replace any connected equipment damaged by surges, including direct lightning strikes, up to $25,000 for life
(valid in the U.S., Canada and Puerto Rico only).
The IBAR12-20ULTRA features 12 total outlets—two front NEMA 5-15R and 10 rear NEMA 5-20R—which are arranged in two exclusive isolated filter banks
that prevent equipment connected to one bank from interfering with equipment connected to the other. These internal barriers also prevent disruptive line noise
from causing A/V distortion, computer lock-ups, data errors and similar problems. Large toroidal chokes, ferrite rod-core inductors, HF/VHF capacitors and
multiple layers of metal oxide varistors remove EMI/RFI interference and prevent system crashes, reboots and performance problems.
Because residential power outlets have three wires—hot line (H), neutral (N) and ground (G)—the IBAR12-20ULTRA protects all three, covering two
protection modes: full normal mode (H-N) and common mode (N-G/H-G).
An integrated 20A circuit breaker protects all outlets and shuts down connected equipment in the event of an overload. A lighted on/off switch with locking
cover provides one-touch control over connected components. Diagnostic LEDs show power, protection and line fault status at a glance. The
IBAR12-20ULTRA mounts to a wall, under a counter or in 1U of rack space using the included hardware.
Features
Network-Grade 3840-Joule Surge Protection for IT or Industrial Electronics
Protects rack-mounted network hardware, retail displays, appliances, power tools and other expensive electronics against even the strongest surges and
spikes
Recommended for network workstations, telecom systems, point-of-sale equipment and audio/video systems requiring AC line protection
Full normal mode (H-N) and common mode (N-G/H-G) line surge suppression
Filters out disruptive EMI/RFI line noise that can cause equipment damage or data loss
1/4
Exceeds IEEE 587 Category A and B surge suppression specifications
12 Outlets Accept Wide Range of Electronic Devices
2 NEMA 5-15R in front, 10 NEMA 5-20R in rear
AC outlets accept most computer, networking and telecom equipment
Isolated Filter Banks Provide Extra Protection
Outlets arranged in 2 exclusive isolated filter banks to limit noise interaction among connected equipment
Block disruptive EMI/RFI line noise that can cause equipment damage or data loss
Premium Safety Features
Lighted on/off switch with locking cover provides one-touch control over connected equipment
Automatic shutoff cuts power to outlets when protection circuit has been compromised
Diagnostic LEDs confirm power, protection and line fault status at a glance
Conforms to current UL 1449 3rd Edition safety standards
Flexible Mounting Options
Mounts into 1U of space in EIA-standard 19 in. racks
Included mounting hardware also allows installation on wall or under counter
Long 15 ft. AC power cord with NEMA 5-20P plug reaches distant outlets
All-metal housing designed for long life
Backed by Tripp Lite’s Ultimate Lifetime Insurance
$25,000 Ultimate Lifetime Insurance covers any connected components damaged by power surge (U.S., Canada and Puerto Rico only)
Specifications
OUTPUT
Frequency Compatibility
Output Receptacles
Output (Watts)
Circuit Breaker (amps)
Right-Angle Outlets
50 / 60 Hz
(12) 5-15R
2400
20
No
INPUT
Nominal Input Voltage(s) Supported
Recommended Electrical Service
Input Connection Type
Input Plug Features
Input Cord Length (ft.)
120V AC
120V (110-125V)
NEMA 5-20P input plug
Space-saving right angle input plug
15
2/4
Input Cord Length (m)
Voltage Compatibility (VAC)
Maximum Surge Amps
Right-Angle Plug
4.57
120
150000
No
USER INTERFACE, ALERTS & CONTROLS
Switches
Diagnostic LED Details
Locking Switch Cover
Red illuminated power switch controls power to all outlets
PROTECTION PRESENT (green), LINE FAULT (red) and LINE OK (green)
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:
Use WEBENCH to design an LED driver circuit and use solar cells to drive street lights. The software first selects the type of LED. TI has prepared many LED solutions, as shown below:...
SendMessage(WM_ICONERASEBKGND, (WPARAM) dc.GetSafeHdc(), 0); I want to make a Wince Gobang program, but WM_ICONERASEBKGND cannot be used in Wince. Is there a replacement for it in Wince? Thank you...
Since I am a novice and don't know how to post pictures, I used the MAX291 simulation in multisim10 and built it with the typical working circuit on DATASHEET, but the simulation had no output, just l...
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guang...[Details]
Power management solutions for today's portable application processors are becoming increasingly integrated. Total power consumption, standby and sleep current consumption affect battery size, bill...[Details]
The TPS92210 is a single-stage LED lighting pulse width modulation (PWM) controller. The TRIAC dimmable solution not only regulates the LED current, but also achieves a power factor close to 1. The...[Details]
To understand how and why OLED power supply affects display image quality, you must first understand OLED display technology and power supply requirements. This article will explain the latest OLED...[Details]
introduction
Incandescent bulbs can emit a variety of light, but in specific applications, only green, red, and yellow light are usually needed - such as traffic lights. If an incand...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
1 Introduction to LED
With the development of science and technology, people have higher and higher requirements on automobile light sources. LED (Light Emitting Diode) has gradually attracted...[Details]
Car lights, whether headlights, fog lights or tail lights, play an important role in driving safety. However, the material of the car lights determines that the probability of damage in a collision...[Details]
a. Keep the battery clean, wipe off the spilled electrolyte, contaminated dirt and dust in time; keep the poles and terminal clamps clean and in good contact, and apply vaseline or butter to preven...[Details]
In the TV monitoring system, in order to complete the collection of information from various information points (video, audio, alarm signal) and the control of various front-end devices (PTZ, lens,...[Details]
Traditionally, when using PLC to control stepper motors, a dedicated stepper motor control intelligent module is usually added to the PLC, and then connected to the drive power supply to realize th...[Details]
(1) Open circuit voltage of the battery
(2) Internal resistance of the battery
(3) Battery operating voltage
(4) Charging voltage
Charging voltage refers to the voltage applied ...[Details]
In recent years, the development of automotive batteries has become a focus of attention. Compared with other rechargeable batteries, lithium-ion batteries have the advantages of high specific ene...[Details]