Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
M
Ω
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
Table 1
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
Operation Mode
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MH z
Please specify the frequency
in x x .x x x x M Hz.
e .g . 14.3181MHz
MHz -
-
-
-
-
-
-
P a c k a g in g
Blank: Bulk (std.)
T: Tape & Reel
(For MJ option only)
Q u a lit y F a c t o r * * *
Minimum
QXXXk
Value
L o a d Capacit anc e (pF)
Please specify CL
(Minimum 10 pF) in pF or
S fo r series
Custo m E SR if other
than st a n d a r d
R□
□: Specify
a value in
Ω
(e .g .: R40)
Operating Temp.
A: -10°C ~ + 60° C
B: -20°C ~ + 70° C
C: -30°C ~ + 70° C
N: -30°C ~ + 85° C
D: -40°C ~ + 85° C
Valu e Added
I
V
QXX
MJ
Operation Mode
Fund. AT > 24MHz
F
FB
O
Freq. Tolerance
1: ± 10 pp m
7: ± 15 pp m
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq . St abilit y
Option s fo r A T -
Cut only *
U * * : ± 1 0 p pm
G: ± 15 ppm
X: ± 20 ppm
W : ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 5 0 p pm
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriat e code numbers for
other trimmed lengths not liste d.
(e.g. Q14 for 0.14 inch (3.55 mm))
Fund. BT>24MHz
3rd OT>66MHz
Insulator Tab
Vinyl Sleeve
T rimmed lea ds
See Ta ble 2
Metal jacket
NOTE:
*:Fr equency Stability ± 100
ppm max at -10 to +60C only
for BT cut.
** : -10 to +60C only.
*** : Quality factor must be
ac companied by a k value
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Tape and reel packaging applies only to MJ (metal jacket) option
E
1.75±0.10
E2
22.25 MIN.
F
11.5±0.10
P2
2.00±0.10
ØD0
1.50±0.10
P0
4.00±0.10
W
24.00±0.30
Dimensions: mm
ATTENTION:
Abracon products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon is required. Please contact Abracon for more information.
LPC1766 and an AD converter make a USB transmission oscilloscope. Can LPC1766 and AD communicate in parallel? [[i] This post was last edited by zhangjun1960 on 2011-9-6 17:32 [/i]]...
I have installed Windows 7 64-bit operating system. There is no problem recognizing other ARM, MCU, FPGA simulators or programmers. Only TI's simulator driver cannot be recognized. As such a large mul...
[i=s]This post was last edited by paulhyde on 2014-9-15 08:56[/i] Does anyone know how the pins of 3DG6C are arranged? Which is the e, c, b pin? . . ....
I just received a text message, very clumsy:Mom and Dad: My friend and I were caught by the police while living together. Please go to the post office and transfer 5,000 yuan to Li Haiyan’s account at...
I think it is well written and easy to understand. It is worth a look. It is mainly GA.pdf. The others are related materials. The things are collected and sorted by people from other forums....
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
Remote keyless entry (RKE) systems have become popular with users, with more than 80% of new cars in North America and more than 70% in Europe equipped with RKE systems. In addition to the obvious ...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
Overview
In spectral measurement, photomultiplier tubes (PMT) and charge-coupled devices (CCD) are often used as photoelectric converters. PMT is used in slow-changing, high-precision spectral...[Details]
Continuity test
A variety of devices need to be checked for continuity, including cable assemblies, printed circuit boards, and connectors to ensure that these components have the expected contin...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]