Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
L
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages L-14 thru L-18. For additional options not shown in catalog, consult Customer Service Center.
Rotary
Switch Function
MA00
SP, 10 pos., 36°
MA02
SP, 2 pos., 36°
MA03
SP, 3 pos., 36°
MA04
SP, 4 pos., 36°
MA05
SP, 5 pos., 36°
MA06
SP, 6 pos., 36°
MA10
SP, 10 pos., 36°
MB00
DP, 5 pos., 36°
MB03
DP, 3 pos., 36°
MB04
DP, 4 pos., 36°
MB05
DP, 5 pos., 36°
MC00
SP, 12 pos., 30°
MC03
SP, 3 pos., 30°
MC07
SP, 7 pos., 30°
MC12
SP, 12 pos., 30°
MD00
DP, 6 pos., 30°
MD06
DP, 6 pos., 30°
ME00
SP, 10 pos., 36°
ME04
SP, 4 pos., 36°
MF00
DP, 5 pos., 36°
MG00
SP, 12 pos., 30°
MH00
DP, 6 pos., 30°
Actuator & Bushing
L1
.650"
long, flatted
L2
Screwdriver slot, flush
L3
.650" long, round
S1
.650" long, flatted
S2
Screwdriver slot, flush
S3
.650" long, round
S6
.785" long, slot
Short/Non-short
N
Non-shorting contacts
Terminations
Z
Solder lug
C
PC Thru-hole
Contact Material
Q
Silver
G
Gold over silver
Seal
D
No seal
F
Splashproof shaft & panel seal
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
L–13
www.ck-components.com
M Series
Half-inch Rotary Switches
SWITCH FUNCTION
36º INDEXING
MODEL NO.
WITH STOP
PINS
MODEL NO.
WITH STOP
RINGS
SP MODELS 36º INDEXING
SCHEMATIC
30º INDEXING
MODEL NO.
WITH STOP
PINS
MODEL NO.
WITH STOP
RINGS
NO.
POLES
SWITCH
FUNCTION
10 Positions
No Stops
2 Positions
3 Positions
4 Positions
5 Positions
6 Positions
10 Positions
5 Positions
No Stops
3 Positions
SP MODELS 30º INDEXING
SCHEMATIC
DP MODELS 36º INDEXING
SCHEMATIC
NO.
POLES
SWITCH
FUNCTION
12 Positions
No Stops
3 Positions
7 Positions
12 Positions
6 Positions
No Stops
6 Positions
MA00
MA02
MA03
SP
ME00
—
—
MC00
SP
MG00
—
—
—
MC03
MC07
MC12
MD00
MA04
MA05
MA06
MA10
MB00
MB03
ME04
—
—
—
MH00
—
DP
MD06
MF00
DP
MB04
MB05
—
—
4 Positions
5 Positions
DP MODELS 30º INDEXING
SCHEMATIC
All models
with all options when ordered with S1-SB stainless steel actuator options.
L
Rotary
NOTE:
Number of positions or stops preset at factory (NOTE: MX00 models have full 360 rotation with no stops. Stop pins or stop rings supplied for user-selectable stops, see above).
All terminals present regardless of number of switch positions. Hardware is available separately, see section “Technical Data and Additional Hardware”.
SP, 36º Indexing
Actuator Shown In Pos. 1
DP, 36º Indexing
Terminal Numbers Marked
On Side Of Housing
Part number shown: MA00L1NZQD
SP, 30º Indexing
Actuator Shown In Pos. 1
DP, 30º Indexing
Terminal Numbers Marked
On Side Of Housing
Part number shown: MC00L1NZQD
Third Angle
Projection
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
L–14
www.ck-components.com
M Series
Half-inch Rotary Switches
ACTUATOR (ZINC ALLOY)
L1
.650" LONG, FLATTED
L2
SCREWDRIVER SLOT, FLUSH
L3
.650" LONG, ROUND
All actuators shown in pos. 1
ACTUATOR (STAINLESS STEEL)
S1
.650" LONG, FLATTED
L
Rotary
S2
SCREWDRIVER SLOT, FLUSH
S3
.650" LONG, ROUND
S6
.785" LONG, SLOT
All actuators shown in pos. 1
All models UL/CSA when ordered with stainless steel actuators.
Third Angle
Projection
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
L–15
www.ck-components.com
M Series
Half-inch Rotary Switches
SHORTING/NON-SHORTING CONTACTS
N
NON-SHORTING CONTACTS
Break-before-make
TERMINATIONS
Z
SOLDER LUG
SP
DP
C
PC THRU-HOLE
SP
DP
PANEL MOUNTING
WITH FLATS
0.213
(5.41)
PC MOUNTING
36
º
INDEXING
SP
DP
WITHOUT FLATS
0.260 DIA
(6.59)
L
Rotary
0.260 DIA
(6.60)
SP
Hardware: All models, one mounting nut and lockwasher
supplied standard. MA00 thru MD00 models: two stop pins
and adhesive mylar washer supplied. ME00 thru MH00
models: two stop rings supplied. Hardware is available
separately, see section “Technical Data and Additional
Hardware”.
PC MOUNTING
30
º
INDEXING
DP
NOTE:
Q contact material standard. Terminal numbers marked on side of housing.
All terminals insert molded. All terminals present regardless of number of switch positions.
Actuators and schematics shown in pos. 1.
CONTACT MATERIAL
OPTION
CODE
CONTACT
MATERIAL
SILVER
1, 2
TERMINAL
PLATING
SILVER
2
GOLD
4
POWER
LOW LEVEL/DRY CIRCUIT
OR POWER
RATING
CARRY: 6 AMPS CONTINUOUS. SWITCH: 250 mA @ 125 V AC
or 28 V DC.
0.4 VA MAX. @ 20 V AC or DC MAX. or, CARRY: 6 AMPS
CONTINUOUS. SWITCH: 250 mA @ 125 V AC or 28 V DC.
Q
G
GOLD OVER
SILVER
3, 4
* Note: See Technical Data section of this catalog for RoHS compliant and compatible definition and specifications.
Question 1 In the second edition of "Electronics" in Photo 1, on page 27, where the question mark is, why is V(t) only the real part taken, and its imaginary part not considered? I searched on the Int...
I want to replace the original 100nh inductor in the RF circuit with a magnetic bead. What size should the magnetic bead be? What is the conversion principle between inductor and magnetic bead? I have...
From the circuit point of view, there are always driving sources and driven loads. If the load capacitance is relatively large, the driving circuit needs to charge and discharge the capacitance to com...
[i=s]This post was last edited by MianQi on 2021-6-21 19:42[/i]Studying the Road to Electric Motor Driving-8: Composition and Decomposition of Forces...
This website introduces the production of the host in the wireless anti-theft alarm system to netizens. It uses the AT89C2051 single-chip microcomputer as the central processing chip, making the funct...
According to foreign media reports, Ford Motor has applied to the U.S. Patent and Social Security Administration (USPTO) for a patent for a remote vehicle control system that may be used in future ...[Details]
Wave soldering is a crucial electronic component soldering technique used in the production of a wide range of electronic devices, from home appliances to computers to avionics. The process is wide...[Details]
Reflow soldering, a common soldering method in modern electronics manufacturing, primarily melts solder paste and pads to form solder joints. With technological advancements, soldering equipment ha...[Details]
With the rapid development of technology, automotive intelligence is increasing at an unprecedented rate. This not only enhances vehicle functionality and comfort, but also places higher deman...[Details]
Ever since the Tesla fire incident, electric cars, already known for their poor reputation, have been subjected to even more scathing criticism. Despite this, many people are still willing to buy t...[Details]
Overview
As handheld voice communication devices become more and more popular, they are increasingly used in noisy environments, such as airports, busy roads, crowded bars, etc. In such noisy ...[Details]
In the electronics manufacturing industry, surface mount technology (SMT) placement machines are core equipment for production lines. However, with many different models available on the market, ch...[Details]
Learned the following information.
Customer product: industrial computer motherboard
Glue application area: CPU/BGA filling
Glue color requirements: black or t...[Details]
The MCX E series is the most reliability- and safety-focused series in NXP's extensive MCX product portfolio.
With the launch of this series, NXP has further enriched its 5V-compatible MCU pr...[Details]
Intel®
Xeon®
6
-
core processors now support the new Amazon EC2 R8i and R8i-flex instances on Amazon Web Services (AWS).
These new instances offer superior performance and fast...[Details]
A tubular motor is an electric motor that is typically used to control the movement of machines and equipment. Tubular motors are generally divided into two categories: linear tubular motors and ro...[Details]
In the period after the switching power supply achieved the "20 kHz" revolution in the 1970s, although improvements and enhancements were made in circuit technology, the development level of the se...[Details]
Tools/Materials
Yitong Chuanglian MODBUS to PROFIBUS Gateway YT-PB-03
Siemens s7-300
This article describes how to configure the YT-PB-03 MODBUS to PROFIBUS gat...[Details]
A scale, a large, ground-mounted scale, is typically used to measure the tonnage of truck cargo. It's the primary weighing device used in factories, mines, and businesses for bulk cargo measurement...[Details]
As a pioneer in the new smart home concept, robot vacuums have captured a significant market share. Robot vacuums, also known as automatic sweepers, smart vacuums, or robot vacuums, are smart home ...[Details]