Reduced footprint from ABLS (standard HC/49US package) by 50%
• Low profile: 2.3mm max. height
• Suitable for RoHS compliant reflow
• Tight stability & extended temperature options
• High reliability & Cost effective
• Resistance welded metal package
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.3mm
Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and not Moisture Sensitive - MSL = N/A: Not Applicable
APPLICATIONS:
• Wireless Applications
• Home electronics
• Computers, modems, and communications
• Microprocessors
STANDARD SPECIFICATIONS:
Parameters
Fre
q
uency Range
*
Standard Frequencies
Operation
Mode
Operating Temperature
S
torage Temperature
Frequency Tolerance
@+25°C
Frequency
Stability
over the Operating
Temperature
(
ref. to +25°C)
Equivalent series resistance (R1)
@+25°C
S
hunt capacitance
(
C0
)
L
oad capacitance
(
C
L)
Drive
L
evel
A
ging
Insulation Resistance
Drive level dependency
(DLD)
-5
18
5
0
100
+5
Minimum
Typical
Maximum
Units
M
H
z
MHz
Notes
12.0
40.0
12.0, 12.288, 13.5, 13.56, 14.31818,
14.7456, 16.0, 18.432, 20.0, 20.5, 24.0,
24.576, 25.0, 26.0, 27.0
Fundamental
(AT-cut)
0
-
40
-50
-50
+70
+125
+50
+50
60
40
25
5
ºC
ºC
ppm
ppm
Ω
pF
pF
µW
ppm
See
options
See
options
See
options
12.000 ~ 16.000MHz
16.001 ~ 30.000MHz
30.001 ~ 40.000MHz
Standard
(See
options if
other than STD)
* Please contact Abracon for other frequencies.
5
00
M
Ω
10nw ~ 100uw,12 points
Change in ESR
(Maximum - Minimum)
over DLD range < 30% ESR max.
@25°C±3°C
First year
@
100Vdc ± 15V
ABRACON IS
ISO9001:2008
CE RTIFIED
2 Faraday, Suite#
B
|
Irvine
|
CA 92618
Revised: 01.06.15
Ph. 949.546.8000
|
Fax. 949.546.8001
Visit
www.abracon.com
for Terms and Conditions of Sale
SMD MICROPROCESSOR CRYSTAL
ABLS7M
PART IDENTIFICATIONS:
(left blank if standard)
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.3mm
ABLS7M -
Frequency in MHz
Please specify the frequency
in MHz. e.g.
12.000MHz
14.31818MHz
Load Capacitance
(pF)
Please specify CL
(Minimum 8pF) in pF
or S for series
Custom ESR if other
than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
MHz -
-
-
-
Packaging
Blank: Bulk
T: Tape & Reel
Operating Temp.
Blank: 0°C ~ +70°C
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J: -40°C ~ +105°C
K: -40°C ~ +125°C
Freq. Tolerance
Blank: ± 50 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
(See Table 1 for details)
Blank: ± 50 ppm
U: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
Table 1 Available Combinations of Operating Temp. and Freq. Stability
Operating Temp.
A: -10°C ~ +60°C
Std.: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J: -40°C ~ +105°C
K: -40°C ~ +125°C
Freq. Stability
U:±10ppm
√
√
G:±15ppm
√
√
√
X:±20ppm
√
√
√
√
W:±25ppm
√
√
√
√
Y:±30ppm
√
√
√
√
√
√
H:±35ppm Std.:±50ppm Q:±100ppm
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Note: Please contact Abracon for other frequency stability and operating temperature range options.
ABRACON IS
ISO9001:2008
CE RTIFIED
2 Faraday, Suite# B
|
Irvine
|
CA 92618
Revised: 01.06.15
Ph. 949.546.8000
|
Fax. 949.546.8001
Visit
www.abracon.com
for Terms and Conditions of Sale
SMD MICROPROCESSOR CRYSTAL
ABLS7M
OUTLINE DIMENSION:
0.299 ±0.02
7.60 ±0.50
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.3mm
0.114 ±0.008
2.90 ±0.20
0.276 ±0.008
7.00 ±0.20
0.091 MAX.
2.30
0.071 MAX.
1.80
0.047
1.20
0.150 ±0.008
3.80 ±0.20
Recommended Land Pattern
0.260 TYPE
6.60
0.008 ±0.004
0.20 ±0.10
0.039 MAX.
1.00
0.012 ±0.008
0.30 ±0.20
0.138
3.50
TYPE
0.079
2.00
MIN
0.138
3.50
TYPE
0.012 ±0.008
0.30 ±0.20
0.102 ±0.008
2.60 ±0.20
Actual Size Comparison
0.102 ±0.008
2.60 ±0.20
ABLS
0.161 MAX.
4.10
ABLS7M
7.0 x 4.1 x 2.3 mm
11.4 x 4.7 x 4.2 mm
0.024 ±0.001
0.60 ±0.02
0.094 ±0.008
2.40 ±0.2
Dimension: inches [mm]
REFLOW PROFILE:
ABRACON IS
ISO9001:2008
CE RTIFIED
2 Faraday, Suite# B
|
Irvine
|
CA 92618
Revised: 01.06.15
Ph. 949.546.8000
|
Fax. 949.546.8001
Visit
www.abracon.com
for Terms and Conditions of Sale
SMD MICROPROCESSOR CRYSTAL
ABLS7M
TAPE & REEL:
T = tape and reel (3000pcs/reel)
Pb
RoHS / RoHS II Compliant
7.0 x 4.1 x 2.3mm
No.
A
C
D
T
F
G
H
Dimensions
(mm)
100 ± 1.0
330 ± 2.0
16.4 ± 1.0
20.4 ± 0.5
13.0 ± 0.2
20.2 min.
1.5 min.
No.
J
K
L
M
N
P
Q
R
S
Dimensions
(mm)
Ø1.5
4.0 ± 0.1
16.0 ± 0.3
7.5 ± 0.1
9.4 ± 0.1
2.5 ± 0.1
0.3 ± 0.05
8.0 ± 0.1
4.4 ± 0.1
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive
Applications. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high
reliability where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environ-
ment, written consent and authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
My experience of queuing up to buy tickets at the North Station these two days: Yesterday, I arrived at the North Station at 6:30 and listened to the broadcast to guide me to the temporary ticket offi...
Disassembling a machine is fun, and it’s fun to keep disassembling it~~~
This post is sponsored by me free of charge. Any similarity is purely coincidental~~~
If eeworld sponsors a new charger, I will...
It is generally believed that the sooner the better, the better, otherwise by next spring there may only be some relatively worse jobs left. However, today I heard someone from a company say that most...
1. The AHB system bus is divided into APB1 (36MHz) and APB2 (72MHz), where 21, meaning APB2 is connected to high-speed devices.2. Stm32f10x.h is equivalent to reg52.h (which contains basic bit operati...
TD-SCDMA (Time Division Synchronous Code Division Multiple Access) is one of the three major standards for the third generation of mobile communications. It is a communication standard with indepen...[Details]
Project Overview
The micro urine analyzer we designed can detect ten parameters of urine, including white blood cells, nitrite, urobilinogen, protein, pH value, occult blood, specific g...[Details]
Digital signal processors have efficient numerical computing capabilities and can provide a good development environment, while programmable logic devices have highly flexible configurability. This...[Details]
In some applications, such as data loggers, it is desirable to have multiplexed analog outputs. When only a single output is active at a time, a voltage-output DAC">digital-to-analog converter (DAC) a...[Details]
Sensors have made inroads into automotive, medical, industrial and aerospace applications. But you may not see anything changing yet. Growing demands for safety, convenience, entertainment and efficie...[Details]
Conventional ECG recorders are one of the main means for doctors to diagnose heart diseases, but they can only record short heartbeats. In many cases, it is difficult to record ECG changes during a...[Details]
Overview
Bioelectric signals are very weak, and there is strong interference when detecting them. Therefore, there are many technical difficulties in designing high-quality bioelectric ampli...[Details]
This article discusses how to use an ultra-low-power RF transceiver chip from Zarlink Semiconductor for pacemakers, neurostimulators, drug pumps, and other such implantable medical devices t...[Details]
With the rapid development of digital technology, various digital display screens have emerged, including LED, LCD, DLP, etc. There are various control systems for various digital large screens, in...[Details]
With the development of automatic control technology, the application of precision air pressure generation and control technology is becoming more and more extensive. However, the traditional valve...[Details]
0 Introduction
Metal halide lamp (MHL) as a green lighting source has been widely used in the field of indoor and outdoor lighting. However, when using this green lighting source, the matc...[Details]
Today's mobile phone production testing faces an increasingly complex environment, with challenges of multiple frequency bands and multiple standards, pressure on production test speed, and pressur...[Details]
1 Introduction
The intelligent meter reading system is a system that reads the data of multiple user meters in a centralized manner through the transmission media by the master station. It...[Details]
In the future, a complete automobile safety system must fully combine gyroscopes, accelerometers, steering wheel and brake pedal position detectors, and tire speed detection systems to accurately ...[Details]
Introduction
The home ECG and blood pressure monitoring system consists of a data acquisition and recording device and a host computer electronic medical record management system. Therefor...[Details]