TA35-CK16MJ20C0

Description
Thermal Circuit Breaker, 3 Pole(s), 2A, 240VAC, Panel Mount,
CategoryCircuit protection    Circuit protection   
File Size3MB,8 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

TA35-CK16MJ20C0 Overview

Thermal Circuit Breaker, 3 Pole(s), 2A, 240VAC, Panel Mount,

TA35-CK16MJ20C0 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
Reach Compliance Codecompliant
Actuator typeROCKER
body width36 mm
body height44.1 mm
Body length or diameter37.4 mm
circuit functionTRIP FREE
Circuit protection typeTHERMAL CIRCUIT BREAKER
Environmental characteristicsIP40; IP00
Installation featuresPANEL MOUNT
Number of poles3
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
physical size37.4mm x 36mm x 44.1mm
Rated current2 A
Rated voltage (AC)240 V
GuidelineCSA; CUL; IEC; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Base Number Matches1
circuit breakers
Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole
TA35 1-pole
TA35 2-pole with CZM23 cover
TA35 3-pole
(pending)
Description
Thermal circuit breaker 1-, 2- or 3-pole
Supplementary protector for general industrial use
Positively trip-free release
Snap-in mounting
Version with illuminated rocker
Different rocker colours
Protection cover for IP65
«Dead-Man»-version (Momentary switch)
Applications
Power tools
Industrial equipment
Equipment for building construction
Medical equipment
Cleaning equipment
Power generators
Commercial and household kitchen appliances
Standards
– IEC 60934
– UL 1077
– CSA C22.2 235
– GB 17701 (pending)
Weblinks
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
TeChniCAl DATA
Rated voltage U
e
1-pole
2-pole
3-pole
Rated current I
n
1- / 2-pole
3-pole
1- / 2-pole, AC 240 V
3-pole, AC 415 V
Accessible range
Terminal side
50 Hz
Impulse 1.2/50 µs
DC 500 V
AC 240 V / 50/60 Hz
DC 32 V
AC 240 V / 50/60 Hz
DC 60 V
AC 415 Y/240 V / 50/60 Hz
0.05 – 20 A
0.05 – 12 A
0.05…20 A: 2000 A, SC (C1)
0.05…12 A: 2000 A
Shock resistance
Degree of protection
IP 40
IP 00
> 2500 V
> 4000 V
> 100 MOhm
Max. switching capacity 1-, 2-pole
for switch only types
3-pole
(without bimetal)
20 A
12 A
Type of tripping
Weight
1-pole
2-pole
3-pole
Overload
IEC 60934
UL 1077
min. 40 cycles @ 6 x I
n
,
cos phi 0.6
min. 50 cycles @ 1.5 x I
n
,
cos phi 0.75 (OLØ)
–30 °C to +60 °C
Admissible ambient
air temperature
Resistance to vibration
IEC 60068-2-6, Test Tc
Conditional short
circuit I
nc
10…60 Hz: ±0.75 mm
60…500 Hz: 10 G
IEC 60068-2-27, Test Ea 30 G / 18 ms
Thermal positively trip free
19 g
32 g
45 g
Dielectric strength
Insulation resistance
Endurance (typical)
Mechanical
50’000 cycles
AC: 1 x I
n
, cos phi 0.6
50’000 cycles
DC: 1 x I
n
, L/R = 2…3ms 50’000 cycles
2
circuit breakers
Apply for a free trial of LM3S8962. Realize remote meteorological information observation.
Mainly learning and applying network port communication.[[i] This post was last edited by xiachaoabc on 2010-10-16 11:36[/i]]...
xiachaoabc Microcontroller MCU
Request for voice recipe resources
I plan to make an unlimited ordering system. I use Lingyang's single-chip microcomputer with voice processing function. I want to realize the function of voice broadcasting recipes, but the voice I re...
ruanapple Embedded System
How to sample AD of multiple channels? If using a state machine, does each channel sample need to be placed in the state machine?
How to sample AD of multiple channels? If using state machine, should each channel sample be placed in the state machine? As the title says... There are many state machine designs for single channel s...
574950880 FPGA/CPLD
The growth path of a logic engineer - about company size
[align=left]When many people start looking for a job, they often face a choice: go to a big company or a small company. Big companies are more formal and you can learn a lot of knowledge. Small compan...
yifeilw FPGA/CPLD
Zigbee network connection allocation problem
If two coordinators are placed close to each other, how can I let a specific child node join the network formed by a specific coordinator? Can I use the method of manually specifying the address? How ...
s361021609 RF/Wirelessly
【TI Technical Article】: Using TI multi-standard base station SoC to achieve comprehensive improvement in performance, efficiency and differentiation
Since the advent of wireless networks, data throughput has grown rapidly, and the demand for mobile network capacity has also increased. Long Term Evolution ( 4G LTE ) provides higher spectral efficie...
德仪DSP新天地 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 818  2242  1852  1338  1208  17  46  38  27  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号