K = ±10% 006 = 6Vdc C = Std ESR S = 13" T&R L = Group A
represent
J = ±5%
010 = 10Vdc L = Low ESR W = Waffle
M = MIL (JAN)
significant
015 = 15Vdc
CWR11
figures 3rd
020 = 20Vdc
See page 7
digit represents
025 = 25Vdc
for additional
multiplier
035 = 35Vdc
(number of
packaging
zeros to follow)
050 = 50Vdc
options.
Reliability Grade
Qualification Termination Finish
Level
Weibull:
H = Solder Plated
0 = N/A
B = 0.1%/1000 hrs.
0 = Fused Solder
T = T Level
90% conf.
Plated
C = 0.01%/1000 hrs. 9 = SRC9000 8 = Hot Solder
90% conf.
Dipped
D = 0.001%/1000 hrs.
9 = Gold Plated
90% conf.
7 = Matte Sn
Z = Non-ER
(COTS-Plus only)
Not RoHS Compliant
LEAD-FREE COMPATI-
BLE
COMPONENT
For RoHS compliant products,
please select correct termination style.
CWR11 P/N CROSS REFERENCE:
CWR11
Type
D
Voltage
Code
C = 4Vdc
D = 6Vdc
F = 10Vdc
H = 15Vdc
J = 20Vdc
K = 25Vdc
M = 35Vdc
N = 50Vdc
^
Termination
Finish
H = Solder Plated
K = Solder Fused
C = Hot Solder
Dipped
B = Gold Plated
686
Capacitance
Code
pF code:
1st two digits
represent
significant
figures 3rd digit
represents
multiplier
(number of zeros
to follow)
*
Capacitance
Tolerance
M = ±20%
K = ±10%
J = ±5%
@
Reliability
Grade
Weibull:
B = 0.1%/1000 hrs.
90% conf.
C = 0.01%/1000 hrs.
90% conf.
D = 0.001%/1000
hrs. 90% conf.
T = T Level
A = Non-ER
+
Surge Test
Option
A = 10 cycles, +25°C
B = 10 cycles,
-55°C & +85°C
C = 10 cycles,
-55°C & +85°C
before Weibull
If blank,
None required
Packaging
Bulk = Standard
\TR = 7" T&R
\TR13 = 13" T&R
\W = Waffle
See page 7
for additional
packaging
options.
Not RoHS Compliant
SPACE LEVEL OPTIONS TO SRC9000*:
TBJ D
Type
Case
Size
686
*
006
C
L
@
9
^
++
Surge Test
Option
45 = 10 cycles,
-55ºC & +85ºC
before Weibull
Not RoHS Compliant
Capacitance Capacitance
Voltage
Standard or Packaging Inspection Level
Code
Tolerance
Code
Low ESR
L = Group A
B = Bulk
pF code:
M = ±20% 004 = 4Vdc
Range
R = 7" T&R
1st two digits
K = ±10% 006 = 6Vdc C = Std ESR S = 13" T&R
represent
J = ±5%
010 = 10Vdc L = Low ESR W = Waffle
significant
015 = 15Vdc
figures 3rd
020 = 20Vdc
See page 7
digit represents
025 = 25Vdc
for additional
multiplier
035 = 35Vdc
(number of
packaging
zeros to follow)
050 = 50Vdc
options.
Reliability Grade
Qualification Termination Finish
Level
Weibull:
H = Solder Plated
9 = SRC9000 0 = Fused Solder
B = 0.1%/1000 hrs.
90% conf.
Plated
C = 0.01%/1000 hrs.
8 = Hot Solder
90% conf.
Dipped
D = 0.001%/1000 hrs.
9 = Gold Plated
90% conf.
*Contact factory for AVX SRC9000 Space Level SCD details.
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage: (V
R
)
Category Voltage: (V
C
)
Surge Voltage: (V
S
)
Temperature Range:
Unless otherwise specified, all technical data relate to an ambient
0.1 μF to 100 μF
±5%; ±10%; ±20%
4
6
10
16
20
25
35
2.7
4
6.7
10
13.3
16.7
23.3
5.3
8
13.3
20
26.7
33.3
46.7
3.5
5.3
8.7
13.3
17.8
22.2
31.1
-55°C to +125°C
temperature of 25°C
85°C:
125°C:
85°C:
125°C:
50
33.3
66.7
44.5
32
■
APRIL 2014
TBJ Series
CWR11 - MIL-PRF-55365/8
Established Reliability, COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR11 P/N
CWR11C^225*@+
CWR11C^475*@+
CWR11C^685*@+
CWR11C^106*@+
CWR11C^156*@+
CWR11C^336*@+
CWR11C^686*@+
CWR11C^107*@+
CWR11D^155*@+
CWR11D^225*@+
CWR11D^335*@+
CWR11D^475*@+
CWR11D^685*@+
CWR11D^106*@+
CWR11D^156*@+
CWR11D^226*@+
CWR11D^476*@+
CWR11D^686*@+
CWR11F^105*@+
CWR11F^155*@+
CWR11F^225*@+
CWR11F^335*@+
CWR11F^475*@+
CWR11F^685*@+
CWR11F^156*@+
CWR11F^336*@+
CWR11F^476*@+
CWR11H^684*@+
CWR11H^105*@+
CWR11H^155*@+
CWR11H^225*@+
CWR11H^335*@+
CWR11H^475*@+
CWR11H^106*@+
CWR11H^226*@+
CWR11H^336*@+
CWR11J^474*@+
CWR11J^684*@+
CWR11J^105*@+
CWR11J^155*@+
CWR11J^225*@+
CWR11J^335*@+
CWR11J^475*@+
CWR11J^685*@+
CWR11J^156*@+
CWR11J^226*@+
CWR11K^334*@+
CWR11K^474*@+
CWR11K^684*@+
CWR11K^105*@+
CWR11K^155*@+
CWR11K^225*@+
CWR11K^335*@+
CWR11K^475*@+
CWR11K^685*@+
AVX COTS-Plus P/N
TBJA 225 * 004 C
TBJ A 475 * 004 C
TBJ B 685 * 004 C
TBJ B 106 * 004 C
TBJ B 156 * 004 C
TBJ C 336 * 004 C
TBJ D 686 * 004 C
TBJ D 107 * 004 C
TBJ A 155 * 006 C
TBJ A 225 * 006 C
TBJ A 335 * 006 C
TBJ B 475 * 006 C
TBJ B 685 * 006 C
TBJ B 106 * 006 C
TBJ C 156 * 006 C
TBJ C 226 * 006 C
TBJ D 476 * 006 C
TBJ D 686 * 006 C
TBJ A 105 * 010 C
TBJ A 155 * 010 C
TBJ A 225 * 010 C
TBJ B 335 * 010 C
TBJ B 475 * 010 C
TBJ B 685 * 010 C
TBJ C 156 * 010 C
TBJ D 336 * 010 C
TBJ D 476 * 010 C
TBJ A 684 * 015 C
TBJ A 105 * 015 C
TBJ A 155 * 015 C
TBJ B 225 * 015 C
TBJ B 335 * 015 C
TBJ B 475 * 015 C
TBJ C 106 * 015 C
TBJ D 226 * 015 C
TBJ D 336 * 015 C
TBJ A 474 * 020 C
TBJ A 684 * 020 C
TBJ A 105 * 020 C
TBJ B 155 * 020 C
TBJ B 225 * 020 C
TBJ B 335 * 020 C
TBJ C 475 * 020 C
TBJ C 685 * 020 C
TBJ D 156 * 020 C
TBJ D 226 * 020 C
TBJ A 334 * 025 C
TBJ A 474 * 025 C
TBJ B 684 * 025 C
TBJ B 105 * 025 C
TBJ B 155 * 025 C
TBJ C 225 * 025 C
TBJ C 335 * 025 C
TBJ C 475 * 025 C
TBJ D 685 * 025 C
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
Parametric Specifications by Rating per MIL-PRF-55365/8
Cap
DC Rated
ESR
DCL max
DF Max
@ 120Hz Voltage @ 100kHz
+25ºC
+85ºC
+125ºC
+25ºC
+(85/125)ºC
μF
V
Ohms
AVX SRC9000 P/N
Case
(μA)
(μA)
(μA)
(%)
(%)
@ 25ºC
@ +85ºC @ +25ºC
TBJ A 225 * 004 C L @ 0 ^ ++ A
2.2
4
8
0.5
5
6
6
9
TBJ A 475 * 004 C L @ 0 ^ ++ A
4.7
4
8
0.5
5
6
6
9
TBJ B 685 * 004 C L @ 9 ^ ++ B
6.8
4
5.5
0.5
5
6
6
9
TBJ B 106 * 004 C L @ 9 ^ ++ B
10
4
4
0.5
5
6
6
9
TBJ B 156 * 004 C L @ 9 ^ ++ B
15
4
3.5
0.6
6
7.2
6
9
TBJ C 336 * 004 C L @ 9 ^ ++ C
33
4
2.2
1.3
13
15.6
6
9
TBJ D 686 * 004 C L @ 9 ^ ++ D
68
4
1.1
2.7
27
32.4
6
9
TBJ D 107 * 004 C L @ 9 ^ ++ D
100
4
0.9
4
40
48
8
12
TBJ A 155 * 006 C L @ 9 ^ ++ A
1.5
6
8
0.5
5
6
6
9
TBJ A 225 * 006 C L @ 9 ^ ++ A
2.2
6
8
0.5
5
6
6
6
TBJ A 335 * 006 C L @ 9 ^ ++ A
3.3
6
8
0.5
5
6
6
9
TBJ B 475 * 006 C L @ 9 ^ ++ B
4.7
6
5.5
0.5
5
6
6
9
TBJ B 685 * 006 C L @ 9 ^ ++ B
6.8
6
4.5
0.5
5
6
6
9
TBJ B 106 * 006 C L @ 9 ^ ++ B
10
6
3.5
0.6
6
7.2
6
9
TBJ C 156 * 006 C L @ 9 ^ ++ C
15
6
3
0.9
9
10.8
6
9
TBJ C 226 * 006 C L @ 9 ^ ++ C
22
6
2.2
1.4
14
16.8
6
9
TBJ D 476 * 006 C L @ 9 ^ ++ D
47
6
1.1
2.8
28
33.6
6
9
TBJ D 686 * 006 C L @ 9 ^ ++ D
68
6
0.9
4.3
43
51.6
6
9
TBJ A 105 * 010 C L @ 9 ^ ++ A
1
10
10
0.5
5
6
4
6
TBJ A 155 * 010 C L @ 9 ^ ++ A
1.5
10
8
0.5
5
6
6
6
TBJ A 225 * 010 C L @ 9 ^ ++ A
2.2
10
8
0.5
5
6
6
9
TBJ B 335 * 010 C L @ 9 ^ ++ B
3.3
10
5.5
0.5
5
6
6
9
TBJ B 475 * 010 C L @ 9 ^ ++ B
4.7
10
4.5
0.5
5
6
6
9
TBJ B 685 * 010 C L @ 9 ^ ++ B
6.8
10
3.5
0.7
7
8.4
6
9
TBJ C 156 * 010 C L @ 9 ^ ++ C
15
10
2.5
1.5
15
18
6
6
TBJ D 336 * 010 C L @ 9 ^ ++ D
33
10
1.1
3.3
33
39.6
6
9
TBJ D 476 * 010 C L @ 9 ^ ++ D
47
10
0.9
4.7
47
56.4
6
9
TBJ A 684 * 015 C L @ 9 ^ ++ A
0.68
15
12
0.5
5
6
4
6
TBJ A 105 * 015 C L @ 9 ^ ++ A
1
15
10
0.5
5
6
4
6
TBJ A 155 * 015 C L @ 9 ^ ++ A
1.5
15
8
0.5
5
6
6
9
TBJ B 225 * 015 C L @ 9 ^ ++ B
2.2
15
5.5
0.5
5
6
6
9
TBJ B 335 * 015 C L @ 9 ^ ++ B
3.3
15
5
0.5
5
6
6
8
TBJ B 475 * 015 C L @ 9 ^ ++ B
4.7
15
4
0.7
7
8.4
6
9
TBJ C 106 * 015 C L @ 9 ^ ++ C
10
15
2.5
1.6
16
19.2
6
8
TBJ D 226 * 015 C L @ 9 ^ ++ D
22
15
1.1
3.3
33
39.6
6
8
TBJ D 336 * 015 C L @ 9 ^ ++ D
33
15
0.9
5.3
53
63.6
6
9
TBJ A 474 * 020 C L @ 9 ^ ++ A
0.47
20
14
0.5
5
6
4
6
TBJ A 684 * 020 C L @ 9 ^ ++ A
0.68
20
12
0.5
5
6
4
6
TBJ A 105 * 020 C L @ 9 ^ ++ A
1
20
10
0.5
5
6
4
6
TBJ B 155 * 020 C L @ 9 ^ ++ B
1.5
20
6
0.5
5
6
6
9
TBJ B 225 * 020 C L @ 9 ^ ++ B
2.2
20
5
0.5
5
6
6
8
TBJ B 335 * 020 C L @ 9 ^ ++ B
3.3
20
4
0.7
7
8.4
6
9
TBJ C 475 * 020 C L @ 9 ^ ++ C
4.7
20
3
1
10
12
6
8
TBJ C 685 * 020 C L @ 9 ^ ++ C
6.8
20
2.4
1.4
14
16.8
6
9
TBJ D 156 * 020 C L @ 9 ^ ++ D
15
20
1.1
3
30
36
6
8
TBJ D 226 * 020 C L @ 9 ^ ++ D
22
20
0.9
4.4
44
52.8
6
9
TBJ A 334 * 025 C L @ 9 ^ ++ A
0.33
25
15
0.5
5
6
4
6
TBJ A 474 * 025 C L @ 9 ^ ++ A
0.47
25
14
0.5
5
6
4
6
TBJ B 684 * 025 C L @ 9 ^ ++ B
0.68
25
7.5
0.5
5
6
4
6
TBJ B 105 * 025 C L @ 9 ^ ++ B
1
25
6.5
0.5
5
6
4
6
TBJ B 155 * 025 C L @ 9 ^ ++ B
1.5
25
6.5
0.5
5
6
6
8
TBJ C 225 * 025 C L @ 9 ^ ++ C
2.2
25
3.5
0.6
6
7.2
6
9
TBJ C 335 * 025 C L @ 9 ^ ++ C
3.3
25
3.5
0.9
9
10.8
6
8
TBJ C 475 * 025 C L @ 9 ^ ++ C
4.7
25
2.5
1.2
12
14.4
6
9
TBJ D 685 * 025 C L @ 9 ^ ++ D
6.8
25
1.4
1.7
17
20.4
6
9
-55ºC
(%)
9
9
9
9
9
9
9
12
9
9
9
9
9
9
9
9
9
9
6
9
9
9
9
9
9
9
9
6
6
9
9
9
9
9
9
9
6
6
6
9
9
9
9
9
9
9
6
6
6
6
9
9
9
9
9
25ºC
Dissipation
Ripple
A
W
(100kHz)
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.15
0.085
0.16
0.110
0.22
0.150
0.37
0.150
0.41
0.075
0.10
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.14
0.085
0.16
0.110
0.19
0.110
0.22
0.150
0.37
0.150
0.41
0.075
0.09
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.14
0.085
0.16
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.08
0.075
0.09
0.075
0.10
0.085
0.12
0.085
0.13
0.085
0.15
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.07
0.075
0.08
0.075
0.09
0.085
0.12
0.085
0.13
0.085
0.15
0.110
0.19
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.07
0.075
0.07
0.085
0.11
0.085
0.11
0.085
0.11
0.110
0.18
0.110
0.18
0.110
0.21
0.150
0.33
Power
Typical Ripple Data by Rating
85ºC
125ºC
25ºC
Ripple
Ripple
Ripple
A
A
V
(100kHz) (100kHz) (100kHz)
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.13
0.06
0.58
0.14
0.06
0.55
0.20
0.09
0.49
0.33
0.15
0.41
0.37
0.16
0.37
0.09
0.04
0.77
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.62
0.14
0.06
0.55
0.17
0.08
0.57
0.20
0.09
0.49
0.33
0.15
0.41
0.37
0.16
0.37
0.08
0.03
0.87
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.62
0.14
0.06
0.55
0.19
0.08
0.52
0.33
0.15
0.41
0.37
0.16
0.37
0.07
0.03
0.95
0.08
0.03
0.87
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.65
0.13
0.06
0.58
0.19
0.08
0.52
0.33
0.15
0.41
0.37
0.16
0.37
0.07
0.03
1.02
0.07
0.03
0.95
0.08
0.03
0.87
0.11
0.05
0.71
0.12
0.05
0.65
0.13
0.06
0.58
0.17
0.08
0.57
0.19
0.09
0.51
0.33
0.15
0.41
0.37
0.16
0.37
0.06
0.03
1.06
0.07
0.03
1.02
0.10
0.04
0.80
0.10
0.05
0.74
0.10
0.05
0.74
0.16
0.07
0.62
0.16
0.07
0.62
0.19
0.08
0.52
0.29
0.13
0.46
85ºC
Ripple
V
(100kHz)
0.70
0.70
0.62
0.52
0.49
0.44
0.37
0.33
0.70
0.70
0.70
0.62
0.56
0.49
0.52
0.44
0.37
0.33
0.78
0.70
0.70
0.62
0.56
0.49
0.47
0.37
0.33
0.85
0.78
0.70
0.62
0.59
0.52
0.47
0.37
0.33
0.92
0.85
0.78
0.64
0.59
0.52
0.52
0.46
0.37
0.33
0.95
0.92
0.72
0.67
0.67
0.56
0.56
0.47
0.41
125ºC
Ripple
V
(100kHz)
0.31
0.31
0.27
0.23
0.22
0.20
0.16
0.15
0.31
0.31
0.31
0.27
0.25
0.22
0.23
0.20
0.16
0.15
0.35
0.31
0.31
0.27
0.25
0.22
0.21
0.16
0.15
0.38
0.35
0.31
0.27
0.26
0.23
0.21
0.16
0.15
0.41
0.38
0.35
0.29
0.26
0.23
0.23
0.21
0.16
0.15
0.42
0.41
0.32
0.30
0.30
0.25
0.25
0.21
0.18
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
APRIL 2014
■
33
TBJ Series
CWR11 - MIL-PRF-55365/8
Established Reliability, COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR11 P/N
CWR11K^106*@+
CWR11K^156*@+
CWR11M^104*@+
CWR11M^154*@+
CWR11M^224*@+
CWR11M^334*@+
CWR11M^474*@+
CWR11M^684*@+
CWR11M^105*@+
CWR11M^155*@+
CWR11M^225*@+
CWR11M^335*@+
CWR11M^475*@+
CWR11M^685*@+
CWR11N^104*@+
CWR11N^154*@+
CWR11N^224*@+
CWR11N^334*@+
CWR11N^474*@+
CWR11N^684*@+
CWR11N^105*@+
CWR11N^155*@+
CWR11N^225*@+
CWR11N^335*@+
CWR11N^475*@+
AVX COTS-Plus P/N
TBJ D 106 * 025 C
TBJ D 156 * 025 C
TBJ A 104 * 035 C
TBJ A 154 * 035 C
TBJ A 224 * 035 C
TBJ A 334 * 035 C
TBJ B 474 * 035 C
TBJ B 684 * 035 C
TBJ B 105 * 035 C
TBJ C 155 * 035 C
TBJ C 225 * 035 C
TBJ C 335 * 035 C
TBJ D 475 * 035 C
TBJ D 685 * 035 C
TBJ A 104 * 050 C
TBJ B 154 * 050 C
TBJ B 224 * 050 C
TBJ B 334 * 050 C
TBJ C 474 * 050 C
TBJ C 684 * 050 C
TBJ C 105 * 050 C
TBJ D 155 * 050 C
TBJ D 225 * 050 C
TBJ D 335 * 050 C
TBJ D 475 * 050 C
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
Parametric Specifications by Rating per MIL-PRF-55365/8
Cap
DC Rated
ESR
DCL max
DF Max
@ 120Hz Voltage @ 100kHz
+25ºC
+85ºC
+125ºC
+25ºC
+(85/125)ºC
μF
V
Ohms
AVX SRC9000 P/N
Case
(μA)
(μA)
(μA)
(%)
(%)
@ 25ºC
@ +85ºC @ +25ºC
TBJ D 106 * 025 C L @ 9 ^ ++ D
10
25
1.2
2.5
25
30
6
8
TBJ D 156 * 025 C L @ 9 ^ ++ D
15
25
1
3.8
38
45.6
6
9
TBJ A 104 * 035 C L @ 9 ^ ++ A
0.1
35
24
0.5
5
6
4
6
TBJ A 154 * 035 C L @ 9 ^ ++ A
0.15
35
21
0.5
5
6
4
6
TBJ A 224 * 035 C L @ 9 ^ ++ A
0.22
35
18
0.5
5
6
4
6
TBJ A 334 * 035 C L @ 9 ^ ++ A
0.33
35
15
0.5
5
6
4
6
TBJ B 474 * 035 C L @ 9 ^ ++ B
0.47
35
10
0.5
5
6
4
6
TBJ B 684 * 035 C L @ 9 ^ ++ B
0.68
35
8
0.5
5
6
4
6
TBJ B 105 * 035 C L @ 9 ^ ++ B
1
35
6.5
0.5
5
6
4
6
TBJ C 155 * 035 C L @ 9 ^ ++ C
1.5
35
4.5
0.5
5
6
6
8
TBJ C 225 * 035 C L @ 9 ^ ++ C
2.2
35
3.5
0.8
8
9.6
6
8
TBJ C 335 * 035 C L @ 9 ^ ++ C
3.3
35
2.5
1.2
12
14.4
6
8
TBJ D 475 * 035 C L @ 9 ^ ++ D
4.7
35
1.5
1.7
17
20.4
6
8
TBJ D 685 * 035 C L @ 9 ^ ++ D
6.8
35
1.3
2.4
24
28.8
6
9
TBJ A 104 * 050 C L @ 9 ^ ++ A
0.1
50
22
0.5
5
12
6
8
TBJ B 154 * 050 C L @ 9 ^ ++ B
0.15
50
17
0.5
5
6
4
6
TBJ B 224 * 050 C L @ 9 ^ ++ B
0.22
50
14
0.5
5
6
4
6
TBJ B 334 * 050 C L @ 9 ^ ++ B
0.33
50
12
0.5
5
6
4
6
TBJ C 474 * 050 C L @ 9 ^ ++ C
0.47
50
8
0.5
5
6
4
6
TBJ C 684 * 050 C L @ 9 ^ ++ C
0.68
50
7
0.5
5
6
4
6
TBJ C 105 * 050 C L @ 9 ^ ++ C
1
50
6
0.5
5
6
4
6
TBJ D 155 * 050 C L @ 9 ^ ++ D
1.5
50
4
0.8
8
9.6
6
8
TBJ D 225 * 050 C L @ 9 ^ ++ D
2.2
50
2.5
1.1
11
13.2
6
8
TBJ D 335 * 050 C L @ 9 ^ ++ D
3.3
50
2
1.7
17
20.4
6
9
TBJ D 475 * 050 C L @ 9 ^ ++ D
4.7
50
1.5
2.4
24
28.8
6
9
-55ºC
(%)
9
9
6
6
6
6
6
6
6
9
9
9
9
9
8
6
6
6
6
6
6
9
9
9
9
25ºC
Dissipation
Ripple
A
W
(100kHz)
0.150
0.35
0.150
0.39
0.075
0.06
0.075
0.06
0.075
0.06
0.075
0.07
0.085
0.09
0.085
0.10
0.085
0.11
0.110
0.16
0.110
0.18
0.110
0.21
0.150
0.32
0.150
0.34
0.075
0.06
0.085
0.07
0.085
0.08
0.085
0.08
0.110
0.12
0.110
0.13
0.110
0.14
0.150
0.19
0.150
0.24
0.150
0.27
0.150
0.32
Power
Typical Ripple Data by Rating
85ºC
125ºC
25ºC
Ripple
Ripple
Ripple
A
A
V
(100kHz) (100kHz) (100kHz)
0.32
0.14
0.42
0.35
0.15
0.39
0.05
0.02
1.34
0.05
0.02
1.25
0.06
0.03
1.16
0.06
0.03
1.06
0.08
0.04
0.92
0.09
0.04
0.82
0.10
0.05
0.74
0.14
0.06
0.70
0.16
0.07
0.62
0.19
0.08
0.52
0.28
0.13
0.47
0.31
0.14
0.44
0.05
0.02
1.28
0.06
0.03
1.20
0.07
0.03
1.09
0.08
0.03
1.01
0.11
0.05
0.94
0.11
0.05
0.88
0.12
0.05
0.81
0.17
0.08
0.77
0.22
0.10
0.61
0.25
0.11
0.55
0.28
0.13
0.47
85ºC
Ripple
V
(100kHz)
0.38
0.35
1.21
1.13
1.05
0.95
0.83
0.74
0.67
0.63
0.56
0.47
0.43
0.40
1.16
1.08
0.98
0.91
0.84
0.79
0.73
0.70
0.55
0.49
0.43
125ºC
Ripple
V
(100kHz)
0.17
0.15
0.54
0.50
0.46
0.42
0.37
0.33
0.30
0.28
0.25
0.21
0.19
0.18
0.51
0.48
0.44
0.40
0.38
0.35
0.32
0.31
0.24
0.22
0.19
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
A simple calculator is designed through the joint debugging of Proteus and Keil C. The calculator can realize the four arithmetic operations of 6-digit integers, and the calculation data and results a...
First of all, I want to confirm what the scientific name of the device in the picture below is, is it IPX or U.FL or something else? Then I want to ask, when drawing the Layout, does the copper under ...
What is the principle of converting a single power supply into a dual power supply? Can you give me a circuit?
6v battery to plus or minus 5v?
Thanks...
Activity Overview: Click here to view (including activity encouragement and activity learning content)Check-in start and end time for this site: August 18th - August 20th (3 days)
Check-in tasks:
1. R...
Before that, we need to upload videos to Daxuetang/Bilibili/Youku/…
Then pass the sharing code toThis web video button is added...Now it is not so troublesome. You can directly upload the video locall...
Remote keyless entry (RKE) systems have become popular with users, with more than 80% of new cars in North America and more than 70% in Europe equipped with RKE systems. In addition to the obvious ...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
From the PIC16F946 datasheet, we know that there are two ways to write values to the LCD for display:
1. Directly write the value to LCDDATA1~LCDDATA23
2. Use disconnect t...[Details]
Only a small number of LED manufacturers can produce high-quality LEDs. For applications that are only used for simple indication, low-quality LEDs are sufficient. However, high-quality LEDs must...[Details]
1. Overview
At present, an information revolution is in the ascendant around the world, led by microelectronics, computers and communication technologies, and centered on information technolog...[Details]
1 Introduction
With the improvement of people's quality of life, lamps are no longer just basic indoor lighting tools, but also a kind of practical art for architectural decoration. When ther...[Details]
Liquid crystal display (LCD) panels have a wide range of applications, from small portable electronic devices to large fixed devices, including digital cameras, laptops, personal data assistants, d...[Details]
1. Introduction
With the increasing popularity of fully automatic washing machines, consumers have higher and higher requirements for their environmenta...[Details]
With the rapid development of wireless
digital communication
, more challenges have been raised for integrated circuit design and testing. In the product design stage, in order to ensure
t...[Details]
The launch of Shenzhou IX is imminent, and Tiangong is welcoming visitors again. Yesterday, Professor Fu Qiang, Vice President of the Institute of Science and Industrial Technology of Harbin Instit...[Details]
0 Introduction
In order to improve the automation control of shortwave transmitters, so that they can automatically process from far to near, the technicians here use the ICS system to complete the ...[Details]
Overview
By transmitting ultrasonic energy into the human body and receiving and processing the returning reflected signals, phased array ultrasound systems can generate images of organs and s...[Details]
When the so-called "copycat phones" that flood the domestic mobile phone market move towards large screens, stereo amplifiers, touch controls, and even GPS navigation and mobile TV, the homogeneity...[Details]
Currently, the commonly used solar cell technologies include monocrystalline silicon solar cells and polycrystalline silicon thin-film solar cells. Production process: Monocrystalline silicon solar...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]