EEWORLDEEWORLDEEWORLD

Part Number

Search

2203516-3

Description
Combination Line Connector
CategoryThe connector    The connector   
File Size2MB,5 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

2203516-3 Overview

Combination Line Connector

2203516-3 Parametric

Parameter NameAttribute value
Objectid7267805385
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOALRIZED
body width1.553 inch
subject depth1.904 inch
body length1.638 inch
Body/casing typePLUG
Connector typeCOMBINATION LINE CONNECTOR
Contact point genderFEMALE
Contact styleSQ PIN-SKT
empty shellNO
Filter functionNO
insulator materialGLASS FILLED POLYAMIDE66
Mixed contactsNO
Installation typeCABLE
Number of rows loaded3
OptionsGENERAL PURPOSE
Total number of contacts24
8
THIS DRAWING IS UNPUBLISHED.
RELEASED FOR PUBLICATION
BY -
ALL RIGHTS RESERVED.
7
20
6
5
4
3
2
REVISIONS
P
LTR
DESCRIPTION
1
DATE
DWN
APVD
C
COPYRIGHT
20
A5
REVISED PER ECO-15-004449
20MAR2015
DLD
WEM
65 $ LEVER
TRAVEL
1
39.45
COMPANY LOGO
MATERIAL: PLUG HOUSING - NYLON 6/6, 35% GLASS-FILLED, YELLOW
TPA - NYLON 6/6, 35% GLASS-FILLED, BLACK
PERIPHERAL SEAL - SILICONE, LIGHT BLUE
MAT SEAL - SILICONE, LIGHT BLUE
LEVER - NYLON 6/6, 35% GLASS-FILLED, TAN
SEAL COVER - NYLON 6/6, 35% GLASS-FILLED, BLACK
D
D
2. APPLICABLE HEADER INTERFACE SPECIFICATION - SEE LAST 2 SHEETS.
3. WIRE DRESS, PART NUMBER 776793-2, TO BE PURCHASED SEPARATELY.
14
4
KEY "D" PART FOR PROTOTYPE USE ONLY.
5. INSTRUCTION SHEET PER TE CONNECTIVITY (TE) SPECIFICATION 408-10334.
6. THIS PRODUCT HAS BEEN VALIDATED FOR USE WITH THE FOLLOWING TERMINAL
PART NUMBERS AND WIRE SIZES:
TE, GENERATION Y, (SILVER PLATED) TERMINAL P/N 2138699-1,
GM P/N tbd
REF. TERMINAL APPLICATION SPECIFICATION 114-13183
2
WIRE RANGE 0.35 - 0.5mm
WIRE INSULATION RANGE: 1.5 to 1.7mm (OUTER DIAMETER)
2
ALSO, WIRE SIZE: 0.75mm
IN 2 CIRCUITS MAXIMUM WITH WIRE INSULATION
OUTER DIAMETER 1.77 to 1.79mm. USE TE TERMINAL P/N 2138699-2,
GM P/N tbd
2
ALSO, GM APPROVED, GMW15626, ISO WIRE, 0.35mm
WIRE SIZE,
1.2mm to 1.4mm WIRE INSULATION OUTER DIAMETER.
THE 2138699-1, -2 TE TERMINALS ARE GM APPROVED PER GM CONNECTOR GROUP
CONNECTOR CHANGE NOTIFICATION BULLETIN #7, TE TERMINALS FOR SDM CONNECTOR,
DATED MARCH 26, 2013.
7
8
9
0.30
48.36
28.55
9
0.30
C
41.61
6.50 TPA IN STAGED
(OPEN) POSITION
3.30 TPA CLOSED
50.68
C
KEY CONFIGURATION "E" IS FOR GM SERVICE ONLY.
PRELIMINARY - PART NOT RELEASED TO PRODUCTION.
TE PART NUMBER AND JULIAN DATE CODE (YY-DDD-HH-MM) ON THIS SIDE.
OPTIONAL MANUAL ASSEMBLY CHARACTER AFTER DATE CODE.
10. FOR BLOCKED CIRCUITS FOR SERVICE, PROTOTYPE, AND PRODUCTION APPLICATIONS,
USE ONLY TE INDIVIDUAL SEAL PLUG P/N 1456538-1.
11
PERIPHERAL SEAL
LEVER
FOR BLOCKED CIRCUITS REQUIRED IN PRODUCTION APPLICATIONS, REFER TO
EXISTING CIRCUIT CONFIGURATIONS (SEE SHEET 3).
12. CONNECTOR MEETS GMW3191, CLASS 1, ENVIRONMENTAL, ELECTRICAL, MECHANICAL,
AND SEALING CLASS (2) "SEALING" TEST PER GM APPROVED/SIGNED TEST PLANS.
SEAL COVER
13. FOR SILVER PLATED TERMINALS, ELECTRICAL PERFORMANCE IS NOT AFFECTED BY
DISCOLORATION OR TARNISH ON SURFACE.
14
ALTERNATE MARKING FOR MANUAL ASSEMBLY. MARK TE PART NUMBER, JULIAN DATE,
AND KEY ON LEVER APPROXIMATELY AS SHOWN. (YYDDD K) Y=YEAR, D=DAY, K=KEY
B
B
COMPANY LOGO
TPA
SEE DETAIL
COMPANY LOGO
PLUG HOUSING
MAT SEAL
B
SCALE
1:1
SCALE
1:1
SECTION
MOLDED IN
SEAL PLUG
A-A
SEE SHEET 3 FOR KEYING CONFIGURATIONS,
AND CIRCUIT CONFIGURATIONS
SEE SHEET 2
THIS DRAWING IS A CONTROLLED DOCUMENT.
DIMENSIONS:
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
DWN
CHK
A
DL DRUMMOND
GENE MILLER
GENE MILLER
-
-
19NOV2012
19NOV2012
19NOV2012
NAME
PART NUMBER
TE Connectivity
A
mm
APVD
DETAIL
SCALE
6:1
MATERIAL
B
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
0.3
0.2
-
-
PRODUCT SPEC
APPLICATION SPEC
2 $
-
-
1
-
-
WEIGHT
-
CUSTOMER DRAWING
A1
00779
SIZE
CAGE CODE
PLUG ASSEMBLY,
SEALED, 24 POSITION, SDM30
LEFT HAND LEVER (NO SHUNTS)
DRAWING NO
RESTRICTED TO
2203516
SCALE
4805 (3/13)
3:1
SHEET
1
OF
5
REV
-
A5
_AFXDLL Issues
I added _AFXDLL to the program and it can't run under WCE, saying that the corresponding component cannot be found. When I remove it, it can run. What's going on? What should I do if I want to add _AF...
lionedwolf Embedded System
Embedded Linux Operating System Learning Plan (Part 3)
Recommended embedded books    Linux Basics    1. "Linux and Unix Shell Programming Guide"    C Language Basics    1. "C Primer Plus, 5th Edition" by Stephen Prata    2. "The C Programming Language, 2n...
rwogn ARM Technology
Does the serial port buffer need to be manually cleared after reading data in WinCE?
Does the data in the serial port need to be cleared after reading?...
pcbrf Embedded System
Technical Life
Technical Life...
安_然 Analog electronics
How to solve the Unicode encoding garbled code?
My device is installed with WINCE and has a serial port connected to a computer. When the computer sends data to WINCE, the data received is garbled. I don't know how to solve this problem?...
msy2009 Embedded System
ADI Data Acquisition System ADUCM360 Series FAQ
[align=left][font=宋体]For the low-power, fully integrated 24-bit data acquisition system ADUCM360/1 series devices, [/font]ADI[font=宋体] experts have summarized some common problems and solutions for us...
新人不新 ADI Reference Circuit

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1297  1541  1191  2756  84  27  32  24  56  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号