Parallel - Fundamental Quartz Crystal, 15.999MHz Nom, SMD, 4 PIN
ABM81-15.999MHZ-6-E4G-T3 Parametric
Parameter Name
Attribute value
Is it Rohs certified?
conform to
Objectid
145206951475
package instruction
SMD, 4 PIN
Reach Compliance Code
unknown
Country Of Origin
Mainland China
YTEOL
7.23
Ageing
2 PPM/FIRST YEAR
Crystal/Resonator Type
PARALLEL - FUNDAMENTAL
Drive level
10 µW
frequency stability
0.0015%
frequency tolerance
30 ppm
JESD-609 code
e4
load capacitance
6 pF
Installation features
SURFACE MOUNT
Nominal operating frequency
15.999 MHz
Maximum operating temperature
70 °C
Minimum operating temperature
physical size
3.2mm X 2.5mm X 0.65mm
Series resistance
120 Ω
surface mount
YES
Terminal surface
Nickel/Gold (Ni/Au)
ABM81-15.999MHZ-6-E4G-T3 Preview
CERAMIC SMD CRYSTAL
ABM8
Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and not Moisture
Sensitive - MSL = N/A: Not Applicable
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
FEATURES:
• Seam sealed package assures high reliability
• Tight tolerance and stability available
• Suitable for RoHS reflow
APPLICATIONS:
• High density applications
• Modems, communication and test equipment
• PMCIA, Wireless applications
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging
Insulation Resistance
TABLE 1- Standard ESR
Frequency (MHz)
10.000 -11.999 (Fund)
12.000 -15.999 (Fund)
16.000 -19.999 (Fund)
20.000 - 29.999 (Fund)
-2
500
ESR( )
max
200
120
70
50
Minimum
10.000
Typical
Maximum
125.000*
Units
MHz
Notes
Contact Abracon for
available F<10MHz
10MHz - 54MHz
64MHz - 125MHz
Please contact Abracon for
available frequencies
Fundamental
3rd Overtone
(Standard Frequencies: 64, 66, 66.6666, 75,
80, 98.304, 100, 125MHz)
-10
+60
-55
+125
-50
+50
-50
See table 1 below
3.0
18.0
10
100
+2
+50
ºC
ºC
ppm
ppm
pF
pF
µW
ppm
M
(see options if other than STD)
Standard
Standard
Standard
(see options if other than STD)
(see options if other than STD)
Standard
(See options if
other than STD)
@25°C±3°C
First year
@ 100Vdc ± 15V
ESR( )
max
40
35
120
80
Frequency (MHz)
30.000 - 39.999 (Fund)
40.000 - 54.000 (Fund)
64.000 - 80.000 (3rd OT)
98.304 - 125.000 (3rd OT)
OPTIONS AND PART IDENTIFICATION: (Left blank if standard)
ABM8
Height (mm)
Blank: 0.80 max
1: 0.65±0.05
2: 0.60±0.10
Frequency in MHz
Please specify the
frequency in MHz.
e.g. 16.000MHz
Load Capacitance (pF)
Please specify CL (min
6pF) in pF or S for series
Custom ESR if
other than standard
R
: Specify a value in
(e.g.: R40)
Operating Temp.
E
Blank: -10°C ~ +60°C
E: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J**: -40°C ~ +105°C
K**: -40°C ~ +125°C
** Frequency stability ±
50ppm and ± 100 ppm
-
MHz -
-
-
-
Packaging
Blank: Bulk
T: 1kpcs / reel
T2: 250pcs / reel
T3: 3kpcs / reel
Freq. Stability
Blank: ± 50 ppm
U: ± 10 ppm(*)
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
(*) Option E, B, and
-10°C to +60°C only.
Freq. Tolerance
Blank: ± 50 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
LLC
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
ABRACON IS
REVISED: 07-1-20
ISO9001-2015
CERTIFIED
CERAMIC SMD CRYSTAL
ABM8
OUTLINE DRAWING:
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
Note:
Due to material availability, the chamfer could be located
on pin #1, 3, or 4. Be advised that the chamfer location has
no impact on the electrical performance of the device.
Table 2
Height (mm)
ABM8
0.80 max
ABM81
0.65+/-0.05
ABM82
0.60+/-0.10
Dimensions: mm
TAPE & REEL:
Option "-T"
: Tape and reel (1,000pcs/reel) : ABM8, ABM82
Tape and reel (3,000pcs/reel) : ABM81
Option "-T2" : Tape and reel (250pcspcs/reel) : ABM8
Option "-T3" : Tape and reel (3,000pcs/reel) : ABM8, ABM82 only
REFLOW PROFILE:
Zone
1
2
3
Dimensions: mm
Description
Temperature
Time
Preheat
Reflow
Peak heat
T
SMIN
~ T
SMAX
150°C ~ 180°C
T
L
230°C
T
P
260°C
±
5°C
60 ~ 120 sec.
30 ~ 40 sec.
10 sec. MAX
ATTENTION:
Abracon LLC’s products are COTS – Commercial-O -The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependent Medical applications or any application requiring high reliability
where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment,
written consent and authorization from Abracon LLC is required. Please contact Abracon LLC for more information.
When debugging the LCD driver of s3c410 under Linux, I encountered this problem. My screen is 320x240 4bp grayscale, so normally each line should be 320x4/8=160byte, that is, when I write the 160th by...
The board is at91sam9g45. I configured linux2.6.30 and compiled uImage to replace the uImage provided by the company. After all the programming is completed, I start the development board and can log ...
The main reason for writing this post is to record the process of doing this project, and to record the process of thinking and practice. I want to make a board that can accurately measure the posture...
Does anyone have experience with the stm8s003 microcontroller? How can I use the serial port to burn a program developed with IAR for stm8 into the microcontroller?...
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Against the backdrop of global warming, energy conservation and emission reduction have become a global hotspot and focus, which has also sounded the clarion call for the take-off of the LED lighti...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]
summary
This article will briefly analyze the success and shortcomings of high-frequency DC-DC switching power supplies in the process of miniaturization (the second basic goal), and propose m...[Details]
1 Introduction
Washing machines are an indispensable household appliance in the home, and they are developing very fast. Fully automatic washing machines are favored by everyone because of their con...[Details]
LonWorks fieldbus technology is widely used, for example, in intelligent buildings, industrial control, environmental protection, etc. Echelon's LonWorks system has been used in the products of tho...[Details]
introduction
Caller ID delivery (CID) is a service provided to the user's phone. The method is that the originating switch transmits the caller number and other information to the terminal swi...[Details]