EEWORLDEEWORLDEEWORLD

Part Number

Search

FMXMB1160GEA-07.999000M-LF

Description
Quartz Crystal,
CategoryPassive components    Crystal/resonator   
File Size260KB,1 Pages
ManufacturerFrequency Management International
Environmental Compliance
Download Datasheet Parametric View All

FMXMB1160GEA-07.999000M-LF Overview

Quartz Crystal,

FMXMB1160GEA-07.999000M-LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145049063327
package instructionHC-49/US, 2 PIN
Reach Compliance Codecompliant
Ageing5 PPM/YEAR
Crystal/Resonator TypePARALLEL - FUNDAMENTAL
Drive level50 µW
frequency stability0.0015%
frequency tolerance25 ppm
load capacitance60 pF
Installation featuresTHROUGH HOLE MOUNT
Nominal operating frequency7.999 MHz
Maximum operating temperature70 °C
Minimum operating temperature
physical sizeL11.5XB4.65XH4.1 (mm)/L0.453XB0.183XH0.161 (inch)
Series resistance100 Ω
surface mountNO
FMXMB
SERIES
Thru-hole Crystals
Low Profile
Thru-Hole Package
Multiple Package Heights
Low Cost
HC-49/US
SPECIFICATIONS
Issue 6 - 10182012
Parameter
Frequency Range
Operation Mode
Load Capacitance (CL)
Frequency Tolerance
Temperature Tolerance
Operating Temperature
Storage Temperature
Equivalent Series Resistance (ESR)
Shunt Capacitance (C0)
Drive Level
Aging @ 25°C
All specifications subject to change without notice.
Specification
3.2 - 90 MHz
See Operation Mode and ESR Table
18 pF Std., 8 - 60 pF and Series available
±30 ppm @ 25°C Std. (See Cal. Tol. for Options)
±50 ppm Std. (See Temp. Tol. for Options)
0 to +70°C Std. (See Temp. Range for Options)
-55 to +125°C
See Operation Mode and ESR Table
7 pF max.
50 uW typical, 1 mW max.
±5 ppm per year max.
HC-49/US
OPERATION MODE AND ESR TABLE
Frequency (MHz)
3.200 - 5.999
6.000 - 7.999
8.000 - 9.999
10.00 - 14.99
15.000 - 40.000
27.000 - 70.000
MODE
Fundamental
Fundamental
Fundamental
Fundamental
Fundamental
3
rd
Overtone
MAX ESR (Ohms)
180
100
70
60
40
120
DIMENSION “H” TABLE
STANDARD MARKING
FMI XX.XXX
XX.XXX FREQUENCY in MHz
Package
B1
B2
B3
Max. Height
0.161” (4.1mm)
0.126” (3.2mm)
0.118” (3.0mm)
NOTE: Standard Specifications for product indicated in
color
Dimensions:
Inches
(mm)
PART DESCRIPTION SYSTEM
MARKING: See Page 52, Format A
FMXM B1 1 18 H J A - XX.XXXXXXM - CM
Product Family
Crystal
Package
B1,
B2 or B3
Mode
1 - Fundamental
3 - 3rd Overtone
Load Cap. (CL)
18 - Standard (pF)
00 - Series
## - Custom (pF)
Cal.
D
E
F
G
H
I
J
X
Tol. @ 25°C
±10 ppm
±15 ppm
±20 ppm
±25 ppm
±30 ppm
±40 ppm
±50 ppm
Custom
*Temp. Tol.
D ±10 ppm
E ±15 ppm
F ±20 ppm
G ±25 ppm
H ±30 ppm
I ±40 ppm
J ± 50 ppm
X Custom
Frequency (MHz)
Temp. Range
**
A 0 to 70 °C
B -20 to 70 °C
C -40 to 85 °C
D -10 to 50 °C
E -10 to 60 °C
F -30 to 60 °C
J 0 to 50 °C
X Custom
Options
BI - Base Insulator
LT - Lead Trimming
LF - Lead Forming
PD - Parameter Data
TD - Temp. Data
CM - Custom Mark
BLANK - None Req’d.
**Check with us for availability.
-55°C TO +125°C Available, Limited Stability Options,
please consult the factory.
1-800-800-XTAL
[9825]
www.fmi-inc.com
11
Allwinner V853 Modify UART pins and UART ports in Tina Linux (2)
#### Scenario 2: Use UART3, need to change from UART0 to UART3 (PB6, PB7) 1. Modify `sys_config.fex` (serial port of BOOT0 and Uboot) The path of `sys_config.fex` is `uart_debug_port` in `device/confi...
aleksib Domestic Chip Exchange
Bluetooth 5 standard
The Bluetooth SIG has officially announced the Bluetooth 5.0 standard. After months of revision, the standard has now been finalized and released. In fact, it is inaccurate to call this generation Blu...
Jacktang Wireless Connectivity
Stepper Machine
Four-wire stepper motor successfully simulated using protues....
chasedreamsl Industrial Control Electronics
****Help!###
***Please ask all the masters###The following is a C51 program. How to write this program with MSP430? ?Hope to give advice to the masters;MOV DPTR,#CMD_STD_RD; Standard read command mode settingMOV R...
huoyunbx Microcontroller MCU
MSP430 Introduction to Interrupt Basics
MSP430 Introduction to Interrupt Basics How can I share the importance of interrupts? I personally think that interrupts are the core of microcontroller system programming. Mastering interrupts skillf...
ljh999 Microcontroller MCU
How to Use Slew Rate to Control EMI
[align=left][color=#000]The synchronous buck converter power topology is used in many industrial and automotive applications; these applications also require low conducted and radiated emissions to en...
maylove Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 989  2476  1152  2860  2112  20  50  24  58  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号