The RPP30 series 2:1 input range DC/DC converters are ideal for high end industrial
applications and COTS Military applications where a very wide operating temperature
range of -40°C to +115°C is required. Although the case size is compact, the conver-
ter contains a built-in filter EN55022 Class B / FCC Level B without the need for any
external components. The RPP30 is available in two case styles: the ribbed case and the
baseplate case for high vibration, bulkhead-mounting or for passive cooling applications.
They are UL-60950-1 certified.
30 Watt
2:1 Single
&
Dual Output
Selection Guide
12V, 24V and 48V Input Types
Part Number
Input
Range
VDC
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
Output
Voltage
VDC
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
±12
±15
±24
±12
±15
±24
±12
±15
±24
Output
Current
mA
8500
6000
2500
2000
1250
8000
6000
2500
2000
1250
8000
6000
2500
2000
1250
±1250
±1000
±625
±1250
±1000
±625
±1250
±1000
±625
Efficiency
(2)
RPP30-123.3S
RPP30-1205S
RPP30-1212S
RPP30-1215S
RPP30-1224S
RPP30-243.3S
RPP30-2405S
RPP30-2412S
RPP30-2415S
RPP30-2424S
RPP30-483.3S
RPP30-4805S
RPP30-4812S
RPP30-4815S
RPP30-4824S
RPP30-1212D
RPP30-1215D
RPP30-1224D
RPP30-2412D
RPP30-2415D
RPP30-2424D
RPP30-4812D
RPP30-4815D
RPP30-4824D
87%
89%
88%
89%
89%
87%
89%
88%
89%
88%
88%
89%
89%
89%
88%
88%
89%
89%
88%
89%
88%
89%
89%
88%
2011/65/EU
6/6
RoHS
UL-60950-1 Certified
E224736
RPP30
* ICE Technology
ICE (Innovation in Converter Excellence)
uses state-of-the-art techniques to
minimise internal power dissipation and
to increase the internal temperature
limits to extend the ambient operating
temperature range to the maximum.
Refer to Application Notes
** add suffix for case options
SUFFIX INFORMATION
none = Standard Ribbed Case
-B = Baseplate Case
For other CTRL logic (-1), case style (-F) or low temperature options (-L, -M, -T) please contact RECOM for availability.
www.recom-international.com
REV: 0/2014
PP-13
POWERLINE+
DC/DC-Converter
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
12V input DC-DC ON (min.)
DC-DC OFF (max.)
24V input DC-DC ON (min.)
DC-DC OFF (max.)
48V input
Input Filter
Input Surge Voltage (100 ms max.)
Start Up Time
Remote ON/OFF
(4)
Remote OFF input current
Output Power
Output Voltage Accuracy
Voltage Adjustability
Minimum Load
Line Regulation
Load Regulation
Cross Regulation (10% <> 100% Load)
Ripple and Noise (20MHz bandwith limited)
(measured with 1µF capacitor across outputs)
low line, high line at full load
10% to 100% full load
Dual Outputs only
3.3V, 5V
All others
50% Load and nominal Vin
Single Output only
DC-DC ON (min.)
DC-DC OFF (max.)
12V, 24V Input
48V Input
RPP30-S_D
Series
9-18VDC
18-36VDC
36-75VDC
8.5VDC
8VDC
17.5VDC
17VDC
35VDC
34VDC
Common Mode EMCType
50VDC
100VDC
20ms typ., 50ms max.
Open or 3.0V < Vr < 5.5V
Short or 0V < Vr < 1.2V
2mA typ.
30W
±1.5%
±10%
0%
±0.3%
±0.5%
3% typ./ 5% max.
100mVp-p typ.
1% p-p Vout typ.
±0.04%/°C max.
25% load step change
% of full load at nominal Vin
800µs
120% typ.
Power Limit, automatic recovery
Converter shutdown if Vout > Vout nominal + 20% typ.
Rated at 2250VDC/1 minute, Flash tested at 3000VDC/1 second
10MΩ min.
3000pF max.
Ambient, Free Convection
260kHz ± 40kHz
-40°C to see Calculation (Note 7)
+115°C
-55°C to +125°C
Ribbed Case: Vertical
Ribbed Case: Horizontal
internal thermistor
7.3°C/Watt
10°C/Watt
5% to 95% RH
Aluminium
Silicone (UL94-V0)
continued on next page
Under Voltage Lockout
nominal Vin and constant resistor load
DC-DC ON
DC-DC OFF
Nominal input
RPP30
Temperature Coefficient
Transient Response
Over Load Protection
Short Circuit Protection
Output Over Voltage Protection (refer to block diagram in Application Notes)
Isolation Voltage
Isolation Resistance
Isolation Capacitance (refer to block diagram in Application Notes)
Operating Frequency
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Over Temperature Protection (refer to block diagram in Application Notes)
Thermal Impedance
(Natural convection)
Relative Humidity
Case Material
(7)
Potting Material
PP-14
REV: 0/2014
www.recom-power.com
POWERLINE+
DC/DC-Converter
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Weight
Packing Quantity
Safety Standards
Thermal Cycling
Vibration
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
(5)
Surge
(5)
Conducted Immunity
MTBF calculated according to BELLCORE TR-NWT-000332
(6)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Ribbed Case
Baseplate Case
RPP30-S_D
Series
39g
43g
4 pcs per Tube
certified UL-60950-1, 1st Edition
complies with MIL-STD-810F
10-55Hz, 12G, 30 Min. along X, Y and Z
Class B
Class B
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Perf. Criteria B
Perf. Criteria A
2195 x 10
3
hours
Notes :
1. Typical values at nominal input voltage and no load/full load.
2. Min. values at nominal input voltage and full load.
3. The ON/OFF pin voltage is referenced to negative input. The pin is pulled high internally
ON/OFF control is standard with positive logic: e.g. RPP30-2405S, RPP30-4805D-B
Positive logic: 0= OFF, 1 = ON. The converter will be ON if the CTRL is left open.
4. Requires an external 100µF low ESR capacitor to meet EN61000-4-4 and EN61000-4-5
5. Case l: 50% Stress, Temperature at 50°C (Ground Benign).
6. To ensure a good all-round electrical contact, the baseplate is pressed firmly into place within the aluminium housing.The hydraulic press can leave
tooling marks and deformations to both the housing and baseplate. The case is anodised aluminium, so there will be natural variations in the case
colour and the aluminium is not scratch resistant. Any resultant marks, scratches and colour varations are cosmetic only and do not affect the
operation or performance of the converters.
Example:
T
case
= Case Temperature
R
thcase-ambient
= 7.5°C/W (vertical)
T
ambient
= Environment Temperature
R
thcase-ambient
= 11.5°C/W (horizontal)
P
dissipation
= Internal losses
Tcase - Tambient
P
in
= Input Power
R
thcase-ambient
=
Pdissipation
P
out
= Output Power
Pout
Ƞ
= Efficiency under given Operating Conditions
P
dissipation
= Pin-Pout =
Ƞ
- Pout
R
thcase-ambient
= Thermal Impedance
RPP30
P
dissipation
= Pin-Pout =
Practical Example:
Pout
Ƞ
- Pout
Take the RPP20-1205S with 50% load. What is the maximum ambient operating temperature? Use converter vertical in application.
Eff
min
= 89% @ V
nom
P
out
= 20W
P
outapp
= 20 x 0.5 = 10W
P
dissipation
=
Ƞ
Pout
Ƞ
- P
out
R
th
=
115°C - Tambient
Tcasemax - Tambient
--> 7.5°C/W =
1.36W
P
dissipation
= ~88% (from Eff vs Load Graph)
10
- 10 = 1.36W
0.88
T
ambient
= 104.8°C
P
dissipation
=
www.recom-international.com
REV: 0/2014
PP-15
POWERLINE+
DC/DC-Converter
Typical Characteristics
RPP30-S_D
Series
RPP30-4805S
Efficiency vs Load Over Vin Eff
100
90
80
70
60
50
40
30
20
10
0
0
20
40
60
80
100
Efficiency (%)
Load Current (A)
Recommended PCB Layout
Ribbed Case
Single Output
RPP30
C1
C2
Fuse
Top View
Dual Output
C2
C1
C3
Fuse
Top View
REV: 0/2014
www.recom-power.com
PP-16
POWERLINE+
DC/DC-Converter
Recommended PCB Layout
RPP30-S_D
Series
Single Output
Dual Output
Baseplate Case- suggested PCB layout
C2
C1
No tracks
in this area
(42 x 30mm)
C3
C3
Fuse
Top View
Input Fuse is recommended. Recommended fuse rating = double maximum input current, time delay type.
Input Capacitor, C1, is required to meet EN61000 Surge and Fast Transient, otherwise it is not required for normal operation.
Output Capacitors C2/C3 are recommended, but not required for normal operation. Typical capacitor values are 1µF MLCC
To ensure optimum thermal performance, use large areas of copper on the PCB to assist with heat dissipation and mount the converter vertically.
The DLP LightCrafter Display 2000 evaluation module (EVM) is a powerful entry-level platform that enables users to evaluate and prototype DLP in applications such as smart home displays, head-up displ...
My VxWorks system uses a floppy disk to boot, but there is a problem: my hardware platform is PC104, when the PC104 has a hard disk, VxWorks boots the system normally; when the hard disk is not mounte...
I use a professional Shangyang Zigbee module, and its computer-to-computer data transmission experiment cannot be debugged. Is there any hero who can help me solve the puzzle? The module can be bound,...
I would like to ask the experts about the 51 memory problem. When writing a program, we will store the data table in 1000H, such as ORG 1000H DB 09H,90H... So, are these data in RAM or ROM? The on-chi...
The resistance across the power supply of my circuit increases from 1.1M to 6.5M in a short period of time. I don't know why? Or is it because of the capacitive reactance of the capacitor that the tot...
"Have you set your calendar reminder?"
On August 24, Nvidia Robotics' official account posted a photo of a black gift box on a social media platform, with an attached greeting card sig...[Details]
On August 22nd, Lantu Motors unveiled a new technology called "Lanhai Intelligent Hybrid" during a live broadcast of CCTV News' "Top Laboratory." The name sounds like another new term, but a closer...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
As AI accelerates across industries, the demand for data center infrastructure is also growing rapidly.
Keysight Technologies, in collaboration with Heavy Reading, released the "Beyo...[Details]
SMT placement machines are important equipment in surface mount technology (Surface Mount Technology). Their performance has a decisive impact on the quality and efficiency of electronic manufactur...[Details]
Based on the commutation technology, thyristor rectifiers are classified into two main types. Line-commutated and force-commutated inverters are commonly used, while other commutated inverters, nam...[Details]
A human-machine interface (HMI) refers to the platform used by people to operate a PLC. This platform provides an interface between programs and humans, serving as a medium for information transmis...[Details]
Reflow soldering, as an electronics assembly process, has become a vital component of the electronics manufacturing industry. Choosing reflow soldering equipment is crucial for improving production...[Details]
With the gradual popularization of new energy vehicles in recent years, more and more people have been able to access and purchase electric vehicles. The structure of electric vehicles is composed ...[Details]
Renesas Electronics' new ultra-low-power RA4C1 MCU features advanced security and a dedicated peripheral set, making it ideal for metering and other applications.
The new product mee...[Details]
Most cameras on the market use chips manufactured by Japanese companies like Sony, Sharp, Panasonic, and LG. South Korea now has the capability to produce chips, but the quality is somewhat inferio...[Details]
The screen is the first thing you notice when evaluating a phone's quality. Its quality directly impacts both visual and operational performance. However, understanding mobile phone screens r...[Details]
Reasons for the wear of the roller press reducer shaft:
1. Since the expansion sleeve is subjected to a large torque, the mating surfaces of the shaft and the sleeve move relative to each other...[Details]
In industrial production, many different controllers are often used, such as those for pressure, flow, electrical parameters, temperature, and sound. However, due to the limitations of the on-site ...[Details]
Naxin Micro releases the NS800RT737x high-performance real-time control MCU (DSP), enabling core control in the industrial and energy sectors.
In power electronics and electric drive...[Details]