EEWORLDEEWORLDEEWORLD

Part Number

Search

DNR18US12-S

Description
AC/DC converter 12v 18w
Categorysemiconductor    Power management   
File Size174KB,4 Pages
ManufacturerAll Sensors
Environmental Compliance  
Download Datasheet Parametric View All

DNR18US12-S Online Shopping

Suppliers Part Number Price MOQ In stock  
DNR18US12-S - - View Buy Now

DNR18US12-S Overview

AC/DC converter 12v 18w

DNR18US12-S Parametric

Parameter NameAttribute value
Datasheets
DNR Series, 5-60 W
Product Photos
DNR18
Other Related Documents
DNR(05 - 60) Series TUV Certificate
DNR(05 - 60) Series UL Certificate
DNR(05 - 60) Series CB Re
RoHS Informati
DNR(05 - 60) Series Declaration of Conformity
Standard Package5
CategoryPower Supplies - External/Internal (Off-Board)
FamilyAC DC Converters
TypeEnclosed
Number of Outputs1
Voltage - Inpu90 ~ 264 VAC
Voltage - Output 112V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (Max)1.5A
Power (Watts)18W
ApplicationsITE (Commercial)
Voltage - Isolati3kV (3000V)
Efficiency77%
Operating Temperature-20°C ~ 70°C
FeaturesAdjustable Output, DC Input Capable, Remote On/Off, Remote Sense, Universal Inpu
Mounting TypeDIN Rail
Size / Dimensi4.53" L x 0.89" W x 3.48" H (115.0mm x 22.5mm x 88.5mm)
Minimum Load RequiredN
ApprovalsCE
Power (Watts) - Max18W
AC DC
5 60 Watts
DNR Series
Up to 89% Efficiency
Full Power to +60 °C
Wide Adjustment Range
DC OK 24 V Models
DC Standby Versions
3 Year Warranty
xppower.com
Rugged Design for Industrial Applications
Specification
Input
• 90-264 VAC, 120-375 VDC (DNR05/10/18)
85-264 VAC, 90-375 VDC (DNR30/60)
Input Frequency
• 47-63 Hz
Input Current
• See tables
Inrush Current
• 5-18 W: 10/18 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Power Factor
• EN61000-3-2, class A
Earth Leakage Current
• 0.8 mA max
Input Protection
• Internal fuse T2A, 250 VAC fitted in line
Input Voltage
General
Efficiency
Isolation
Switching Frequency
Signals
• See tables
• 3000 VAC Input to Output, 1500 VAC Input
to Ground, 500 VAC Output to Ground
• 132 KHz typical, 55-90 kHz (DNR60)
• DC ON indicator LED Green: All models
DC LOW indicator LED Red: 5-18 W models
DC OK: 24 V 30-60 W models
DC OK: All standby models
• 800 kHrs typical Bellcore, Issue 6 at +40 °C,
GB (DNR05/10/18), 530 kHrs typical
Bellcore, Issue 6 at +40 °C, GB (DNR30/60)
• Compatible with TS35/7.5 or TS35/15
MTBF
DIN Rail
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
See tables
See tables
±1%
No minimum load required
<1 s (may increase at low
temperature extremes)
<150 ms
30/130 ms at 115/230 VAC (DNR05)
25/100 ms at 115/230 VAC (DNR10)
20/75 ms at 115/230 VAC (DNR18)
20/30 ms at 115/230 VAC (DNR30)
20/30 ms at 115/230 VAC DNR60)
5-18 W: ±1.0% max
30-60 W: ±0.5% max
5-18 W: ±2.0% max
30-60 W: ±0.5% max
Redundancy module DPM10 available
for load currents up to 10 A (not with
standby system), contact sales
4% max deviation recovery to within
1% in 2 ms for a 50% load change
50 mV pk-pk, 20 MHz bandwidth (may
increase at low temperature extremes)
Output clamps at 120-145% Vnom,
auto recovery
110-145% constant current (DNR05-18)
105-150% power limited (DNR30/60)
Power limited, auto recovery
±0.03%/°C
Environmental
Operating Temperature
• -20 °C to +70 °C (DNR05/10/18)
-40 °C to +70 °C, start up at -35 °C
(DNR30/60), all units derate linearly from
60 °C (see derating curves)
Cooling
• Convection-cooled with 25mm free space
all sides
Operating Humidity
• 20-95% RH, non-condensing
Storage Temperature
• -25 °C to +85 °C (DNR05/10/18)
-40 °C to +85 °C (DNR30/60)
Shock
• 15 g, 11 ms, X, Y & Z axis, 3 shocks/axis
in both directions
Vibration
• 2 g, 10 Hz to 500 Hz, along X, Y & Z axis,
60 mins/axis, mounted on rail
Line Regulation
Load Regulation
Parallel Operation
Transient Response
Ripple & Noise
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
EN55022, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, level 4, Perf Criteria A
EN61000-4-3, level 3, Perf Criteria A
EN61000-4-4, level 4, Perf Criteria A
EN61000-4-5, installation class 3,
Perf Criteria A
EN61000-4-6, level 3, Perf Criteria A
EN61000-4-8, level 4 Perf Criteria A
EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
EN60950-1, UL508 Pollution Degree 2,
UL1310 class 2 power recognised,
See note 3 & ratings table,
UL60950-1 Overvoltage Category II,
UL508 Overvoltage Category III,
DNR30 & DNR60: SEMI F47
ANSI/ISA 12.12.01. Class 1, Division 2
Groups A,B,C and D
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
Discussion on RS485 electric energy meter communication protocol DL645!
I have been learning the communication RS485 of the microcontroller recently, and implementing the program of the DL645 electric energy meter communication protocol. I have drawn many flow charts but ...
single MCU
42 Chinese wives made a foreigner vomit blood and die
: A foreigner who was learning Chinese vomited blood and died because he saw the synonym list of the word wife that Lao Liu gave him: 1, spouse 2, wife 3, wife 4, madam 5, madam 6 , lover 7, wife 8 , ...
qufuybj Talking
Qorvo Launches New Highly Configurable, Compact PMIC Serving IoT and Space-Constrained Applications
The CT88420 has an input voltage range of 2.7 V to 5.5 V and provides two 4 A and two 2 A buck regulators, as well as two 400 mA LDOs. Regulator 1 and the LDO can be configured as load switches, and r...
btty038 RF/Wirelessly
msp430g2553TACCTL0 cannot enter interrupt
Use launchpad to capture external pulses; TACTL is used as timing clock, and TACCTL0 captures pulses; but the capture interrupt can never be entered. The external pulse is provided by the signal gener...
断桥 Microcontroller MCU
How should I deal with the warnings I encountered during QUARTUS simulation? Please continue to help me~~~~
1.Warning: Can't display state machine states -- register holding state machine bit "|times|t_state.t0" was synthesized away 2.Warning: Ignored node vector in source file. Cannot find corresponding no...
wangdj1107 FPGA/CPLD
Recruiting WinCE embedded engineers, hardware engineers
Our company is a newly established company with a strong market, but we are in need of a group of experienced, passionate and entrepreneurial technicians to join us. We will give developers great free...
richpowerHK Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1518  2181  2669  2660  879  31  44  54  18  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号