EEWORLDEEWORLDEEWORLD

Part Number

Search

DP2-62E

Description
sensor pressure 1mpa gauge
CategoryThe sensor   
File Size570KB,15 Pages
ManufacturerPanasonic
Websitehttp://www.panasonic.co.jp/semicon/e-index.html
Environmental Compliance  
Download Datasheet Parametric View All

DP2-62E Overview

sensor pressure 1mpa gauge

DP2-62E Parametric

Parameter NameAttribute value
Datasheets
DP2 Series
Product Photos
DP2-6
Standard Package1
CategorySensors, Transducers
FamilyPressure Sensors, Transducers
Pressure TypeGauge
Operating Pressure145 PSI
Port SizeFemale, M5
OutpuOpen Collec
Accuracy-
Voltage - Supply12 V ~ 24 V
Termination StyleConnec
Operating Temperature-10°C ~ 50°C
Package / CaseModule Box with Display
Factory Setting-
Dynamic CatalogDP2 Series
Other Names1110-2445
PRESSURE SENSORS
DP2
SERIES
Digital
Automatic sensitivity With analog
output
setting
High-performance Digital Pressure Sensor
DP5/DPH
Head-separated
DP2
DP3
Digital Display
DP4
Complete functionality!
Selection from a wide
lineup
* Passed the UL 991 Environment Test
* UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended use: UL991, SEMI S2-0200]
Conforming to
EMC Directive
UL Recognition
(Excluding 5 m cable length type)
High accuracy
high resolution
high speed
It achieves a 2.5 ms, or less, response
time at a high resolution of 1/1,000.
It enables highly accurate sensing with its
excellent repeatability and temperature
characteristics.
Clearly visible LED display with 3
1
/
2
digits
Bright red LED 7-segment display having 3
1
/
2
digits, 10 mm
0.394 in
high. The displayed
figures are remarkably noticeable not only in
a dark area, but also in a well-lit place.
Setting with easy key operation
Initialization and threshold value
settings are easily done by key
operation while seeing the values on
the display.
PE
LED Bar Display
DP-M
Response time
2.5 ms or less
Repeatability
Within
0.2 % F.S.
1 digit
Temperature characteristics
Within
1 % F.S.
Incorporates
minus sign
‘ ’
indication
Four output modes enable versatile pressure level control
1
Hysteresis mode
Hysteresis
Comparative
Output 1
OFF
ON
Comparative
Output 2
OFF
0 Set Value 1 (P-1) Set Value 2 (P-2)
High pressure (Positive pressure type)
High vacuum (Vacuum pressure type)
ON
ON
Comparative
Output 1
OFF
ON
Comparative
Output 2
OFF
0 Set Value 1 (P-1) Set Value 2 (P-2)
High pressure (Positive pressure type)
High vacuum (Vacuum pressure type)
Selection from six pressure units
The pressure unit can be selected
from six different systems to suit your
requirement.
The selectable pressure units differ
with the sensor type. When the pres-
sure unit is changed, the measured
pressure value and the set values
are automatically converted.
International
System of
Units (SI)
2
Window comparator mode
Hysteresis
Hysteresis
(
)
The common hysteresis of the comparative
outputs can be set, as desired, with the set values.
The comparative outputs can be turned ON or
OFF by a pressure which is within the pressure
range set by Set Value 1 and Set Value 2.
3
Dual output mode
Hysteresis
ON
Comparative
Output 1
OFF
ON
Comparative
Output 2
OFF
0 Set Value 1 (P-1) Set Value 2 (P-2)
High pressure (Positive pressure type)
High vacuum (Vacuum pressure type)
4
Automatic sensitivity setting mode
Hysteresis
ON
Comparative
Output 1
OFF
ON
Comparative
OFF
Output 2
0 Set Value 1 (P-1) Set Value 2 (P-2)
Set Value 3 (P-3)
High pressure (Positive pressure type)
High vacuum (Vacuum pressure type)
inHg
mmHg
kPa
(Note)
psi
kgf/cm
2
bar
: Vacuum pressure type
: Positive pressure type
Note: ‘MPa’ in case of
DP2-22
,
DP2-42
DP2-62
.
and
The outputs can be put to different use, such as,
detection of different kinds of objects, control
function, alarm function etc.
Using actual objects, if the pressure values for OK
objects and NG objects are input, then the sensor
is automatically set to the optimum pressure value
(mid-value).
792
Can any prawn help me find out why the interrupt cannot respond?
#pragma config POSCMOD = #include #include #define delayms(x) \ { \ int i; \ i = x*10; \ while((--i) != 0); \ } static int count =0; void __ISR(_CHANGE_NOTICE_VECTOR, ipl1) CNIntHandler( void ) { int ...
yaschiro Embedded System
Is there anyone who makes a multimedia decoder for Audi?
Please contact me at wkoji@163.net. If you want to cooperate on a project, it would be best if you are in Hangzhou....
shanqiubin Embedded System
ISP
Please tell me how to write program to EEPROM using ISP programmer, thank you!!...
丞恭 MCU
How to clear the data in the receive FIFO
Recently, I developed a DA card system on the F28035 minimum system board. One board sends data, and the other receives data. Data needs to be sent and received through the send and receive FIFOs. Bot...
jiangpeng DSP and ARM Processors
Doubts about learning wince driver
Dear bosses, I have the following doubts when learning wince drivers: 1. How do drivers relate to system events? For example, if I write a driver for an LCD screen, will wince know to display it on it...
wind518 Embedded System
Hey guys, what is the best solution for 3G to serial port conversion?
From EEWORLD cooperation group: 63762526 Group owner: wangkj Is it feasible to use linux + 3G module and then use linux pppd and linux protocol stack plus socket programming?...
xixihaha Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2368  36  2373  978  785  48  1  20  16  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号