Enclosed Switch
SHL
Subminiature Enclosed Switch (Measuring
48 x 17.5 x 45 mm) with High Sealing
Property
• Built-in coil spring type basic switch housed in rigid zinc diecast
alloy casting boasts long life and high precision.
• Requires nearly the same operating force as conventional basic
precision switches (2.35 to 3.92 N).
• Molded terminal model is available.
• Operation indicator model is also available.
• Approved by EN, UL, CSA, and CCC (Chinese standard).
Model Number Structure
■
Model Number Legend
Standard Models
SHL-@55-@
1
1. Actuator
D:
Q:
Q22:
Q21:
W:
W1:
W2:
W21:
W3:
W31:
2
Plunger
Panel mount plunger
Panel mount roller plunger
Panel mount crossroller plunger
Short hinge lever
Hinge lever
Short hinge roller lever
Hinge roller lever
One-way action short hinge roller lever
One-way action hinge roller lever
2. Rated Current
None: Standard
01:
Micro Load
Note:
Refer to page 135 for
Molded Terminal Models.
Ordering Information
■
List of Models
Actuator
Standard model
SHL-D55
SHL-Q55
SHL-Q2255
SHL-Q2155
SHL-D55-01
SHL-Q55-01
SHL-Q2255-01
SHL-Q2155-01
Micro voltage
Plunger
Panel mount plunger
Panel mount roller plunger
Panel mount crossroller plunger
Short hinge lever
SHL-W55
SHL-W55-01
128
Enclosed Switch
SHL
Actuator
Standard model
SHL-W155
SHL-W255
SHL-W2155
SHL-W355
SHL-W155-01
SHL-W255-01
SHL-W2155-01
SHL-W355-01
Micro voltage
Hinge lever
Short hinge roller lever
Hinge roller lever
One-way action short hinge roller lever
One-way action hinge roller lever
SHL-W3155
SHL-W3155-01
Specifications
■
Approved Standards
Agency
UL
CSA
TÜV Rheinland
CCC (CQC)
Standard
UL508
CSA C22.2 No. 14
EN60947-5-1
GB14048.5
File No.
E76675
LR45746
R9451332
2003010305072162
Note:
Ask your OMRON representative for information on approved models.
■
Approved Standard Ratings
UL/CSA
A300
Rated voltage
120 VAC
240 VAC
Carry current
Make
10 A
60 A
30 A
6A
3A
Current
Break
Make
7,200 VA
720 VA
Volt-amperes
Break
TÜV (EN60947-5-1), CCC (GB14048.5)
Model
SHL-@55
SHL-@55-01
SHL-@55-L
SHL-@55-01L
SHL-@55-01L2
SHL-@55-L3
SHL-@55-01L3
SHL-@55-L4
SHL-@55-01L4
Category and rating
AC-15 2 A/125 V
DC-12 2 A/48 V
AC-14 0.1 A/125 V
DC-12 0.1 A/48 V
AC-15 2 A/125 V
AC-14 0.1 A/125 V
DC-12 0.1 A/12 V
DC-12 2 A/24 V
DC-12 0.1 A/24 V
DC-12 2 A/24 V
DC-12 0.1 A/24 V
5A
4A
0.5 A
0.5 A
5A
0.5 A
0.5 A
4A
0.5 A
4A
0.5 A
I the
Note:
For details on the above models, refer to
“Molded Terminal Models” on page 135.
Enclosed Switch
SHL
129
■
General Ratings
Rated voltage
NC
125 VAC
250 VAC
480 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Note: 1.
2.
3.
4.
10 A
10 A
2A
10 A
10 A
5A
0.4 A
0.2 A
Non-inductive load
Resistive load
NO
1.5 A
1.5 A
---
2A
2A
1.5 A
0.4 A
0.2 A
Lamp load
NC
NO
3A
2A
---
5A
5A
1.5 A
0.05 A
0.03 A
NC
Inductive load
Inductive load
NO
2.5 A
1.5 A
---
2A
2A
1.5 A
0.05 A
0.03 A
Motor load
NC
NO
NC
15 A max.
NO
Inrush current
The above figures are for steady-state currents.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
Lamp load has an inrush current of 10 times the steady-state current.
Motor load has an inrush current of 6 times the steady-state current.
Micro Voltage/Current Load Model
Rated voltage
NC
125 VAC
8 VDC
14 VDC
30 VDC
0.1 A
0.1 A
0.1 A
0.1 A
Non-inductive load
Resistive load
NO
■
Characteristics
(For SHL-W155)
Degree of protections (see note 3)
Durability (see note 4)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
IP67 (EN60947-5-1)
Mechanical:
Electrical:
Mechanical:
Electrical:
50/60 Hz
100 M
Ω
min. (at 500 VDC)
15 m
Ω
max. (initial value)
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal part and ground, and
between each terminal and non-current-carrying metal part
150 V (EN60947-5-1)
1,000 VAC max., 300 VDC max. (EN60947-5-1)
3 (EN60947-5-1)
10 A fuse type gI or gG (IEC269)
100 A (EN60947-5-1)
5 A (EN60947-5-1)
Class II (grounding not required with double insulation)
1,000 VAC max., 300 VDC max. (EN60947-5-1)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction:
Malfunction:
Operating:
Operating:
1,000 m/s
2
min.
300 m/s
2
min.
–10
°
C to 80
°
C (with no icing)
35% to 95%
10,000,000 operations min.
500,000 operations min.
120 operations/min
30 operations/min
0.1 mm to 0.5 m/s (hinge lever models)
Rated insulation voltage (U
i
)
Switching overvoltage
Pollution degree (operating environment)
Short-circuit protective device (SCPD)
Conditional short-circuit current
Conventional enclosed thermal current
(I
the
)
Protection against electric shock
OFF reverse voltage
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight (see note 5)
Approx. 62 to 72 g
Note: 1.
2.
3.
4.
The above figures are for steady-state currents.
The above ratings may vary depending on the model. Contact your OMRON representative for further details.
The head section of the plunger type SHL-D(Q)@@ is excluded.
Durability values are calculated at an operating temperature of 5
°
C to 35
°
C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
5.
The values are for the plunger-type models.
130
Enclosed Switch
SHL
Connections
■
Contact Form
(COM) 1
2 (NC)
4 (NO)
Nomenclature
Movable plunger
Rubber cap (NBR)
Die-cast case (zinc die-cast)
Seal rubber (NBR)
Terminal protection cover
Screw terminal
Seal packing (NBR)
Engineering Data
■
Electrical Durability
Ambient temperature: 5°C to 35°C
Ambient humidity: 40% to 50%
Operating frequency:
30 operations/min.
(cosφ = 1)
250 VAC
Durability (x 10
4
operations)
Switching current (A)
Enclosed Switch
SHL
131
Dimensions
Note: 1.
All units are in millimeters unless otherwise indicated.
2.
Unless otherwise specified, a tolerance of
±
0.4 mm applies to all dimensions.
Model
7.8 dia. (see note)
Two, 4.2 dia.
holes
M14
×
1
Plunger
SHL-D55, SHL-D55-01
SHL-D55
SHL-D55-01
9.81 N
1.96 N
1.5 mm
2 mm
0.5 mm
34
±
0.8 mm
---
OF max.
RF min.
PT max.
OT min.
MD max.
OP
FP max.
16.9
15
×
15
9.6
Note:
Stainless steel pin plunger
Terminal
protective
cover
Rubber seal
Panel Mount Plunger
SHL-Q55, SHL-Q55-01
Model
7.8 dia. (see note)
M14
×
1
Two hexagon nut
(thickness: 2.5,
width: 17)
SHL-Q55
SHL-Q55-01
9.81 N
1.96 N
1.5 mm
2 mm
0.5 mm
34
±
0.8 mm
---
OF max.
RF min.
PT max.
OT min.
MD max.
16.9
Note:
Stainless steel pin plunger
15
×
15
9.6
OP
FP max.
Panel Mount Roller Plunger
SHL-Q2255, SHL-Q2255-01
Model
11 dia.
×
4.7 (see note)
SHL-Q2255
SHL-Q2255-01
9.81 N
1.96 N
1.5 mm
2 mm
0.5 mm
43
±
0.8 mm
---
OF max.
Two hexagon nut
(thickness: 2.5
width: 17)
RF min.
PT max.
OT min.
MD max.
OP
16.9
15
×
15
9.6
FP max.
Note:
Stainless sintered alloy roller
Panel Mount Crossroller Plunger
SHL-Q2155, SHL-Q2155-01
Model
11 dia.
×
4.7 (see note)
SHL-Q2155
SHL-Q2155-01
9.81 N
1.96 N
1.5 mm
2 mm
0.5 mm
43
±
0.8 mm
---
OF max.
Two hexagon nut
(thickness: 2.5
width: 17)
RF min.
PT max.
OT min.
MD max.
OP
FP max.
16.9
Note:
Stainless sintered alloy roller
15
×
15
9.6
132
Enclosed Switch
SHL