Slim Safety Door Switch
D4GS-N
CSM_D4GS-N_DS_E_7_4
Slim Safety Door Switches with IP67 Rating
• Slim design with a width of only 17 mm
(three-contact models).
• Reversible design allowing either front or rear mounting.
• Built-in Switches with two- or three-terminal contact
construction are available.
• Operation Key with rubber mounting hole to absorb vibration and
shock.
• IP67 degree of protection.
Be sure to read the
“Safety Precautions”
on page 9.
For the most recent information on models that have been certified
for safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
Switch
D4GS-N@@-@
1 2 3
Operation Key
D4GS-NK@
1
1. Built-in Switch
1: 1NC/1NO (slow-action)
2: 2NC (slow-action)
3: 2NC/1NO (slow-action)
4: 3NC (slow-action)
2. Direction of Operation
Key Insertion
R: Horizontal
T: Vertical
3. Cable Length
Blank: 1 m
3:
3m
5:
5m
1. Operation Key Type
1: Horizontal mounting
2: Vertical mounting
4: Adjustable mounting (Vertical upward)
4-2: Adjustable mounting (Vertical downward)
Ordering Information
List of Models
Switches (Operation Keys are sold separately.)
Consult with your OMRON representative when ordering any models that are not listed in this table.
Appearance
Direction of
Operation Key
insertion
Cable length
1m
Horizontal
3m
5m
1m
Vertical
3m
5m
1NC/1NO
(Slow-action)
D4GS-N1R
D4GS-N1R-3
D4GS-N1R-5
D4GS-N1T
D4GS-N1T-3
D4GS-N1T-5
2NC
(Slow-action)
D4GS-N2R
D4GS-N2R-3
D4GS-N2R-5
D4GS-N2T
D4GS-N2T-3
D4GS-N2T-5
2NC/1NO
(Slow-action)
D4GS-N3R
D4GS-N3R-3
D4GS-N3R-5
D4GS-N3T
D4GS-N3T-3
D4GS-N3T-5
3NC
(Slow-action)
D4GS-N4R
D4GS-N4R-3
D4GS-N4R-5
D4GS-N4T
D4GS-N4T-3
D4GS-N4T-5
Operation Keys
Type
Horizontal mounting
D4GS-NK1
Model
Type
Model
Adjustable mounting
(Vertical upward)
D4GS-NK4
Vertical mounting
D4GS-NK2
Adjustable mounting
(Vertical downward)
D4GS-NK4-2
1
D4GS-N
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
•
•
•
•
•
Machinery Directive
Low Voltage Directive
EN ISO 14119
EN60204-1
GS-ET-15
Certified Standards
Certification body
TÜV SÜD
UL
*
CQC (CCC)
Standard
EN60947-5-1
(certified direct
opening)
UL508
CSA C22.2 No. 14
GB14048.5
File No.
Consult your OMRON
representative for
details.
E76675
Consult your OMRON
representative for
details.
*
Certification for CSA C22.2 No. 14 is authorized by the UL mark.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Item
Utilization category
AC-15
0.75 A
240 V
DC-13
0.27 A
250 V
Rated operating current (I
e
)
Rated operating voltage (U
e
)
Note:
Use a 10 A fuse type
gI
or
gG
that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
C300
Rated voltage
120 VAC
240 VAC
Carry current
2.5 A
Current (A)
Make
15
7.5
Break
1.5
0.75
Volt-amperes (VA)
Make
1,800
Break
180
Q300
Rated voltage
125 VDC
250 VDC
Carry current
2.5 A
Current (A)
Make
0.55
0.27
Break
0.55
0.27
Volt-amperes (VA)
Make
69
Break
69
2
D4GS-N
Characteristics
Interlock type
Coding level
Degree of protection
*1
Durability
*2
Operating speed
Operating frequency
Direct opening force
*4
Direct opening travel
*4
Contact resistance
Minimum applicable load
*5
Rated insulation voltage (U
i
)
Rated frequency
Protection against electric shock
Pollution degree (operating environment)
Between terminals of
same polarity
Impulse withstand
voltage (Uimp)
(EN60947-5-1)
Between terminals of
different polarity
Between each
terminal and
non-current carrying
metallic parts
Mechanical
Electrical
Type 2 (EN ISO 14119)
Low level coded (EN ISO 14119)
IP67 (EN60947-5-1)
1,000,000 operations min.
100,000 operations min. (1 A resistive load at 125 VAC)
*3
0.1 to 0.5 m/s
30 operations/minute max.
60 N min.
10 mm min.
300 mΩ max. (with 1 m cable)
500 mΩ max. (with 3 m cable)
700 mΩ max. (with 5 m cable)
Resistive load of 4 mA at 24 VDC (N-level reference value)
250 V
50/60 Hz
Class II (double insulation)
3 (EN60947-5-1)
2.5 kV
4 kV
6 kV
100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals of
different polarities, and between each terminal and non-current carrying metal parts
2
×
2 mm min.
Insulation resistance
Contact gap
Vibration resistance
Shock resistance
Malfunction
Destruction
Malfunction
10 to 55 Hz, 0.35 mm single amplitude
1,000 m/s
2
min.
300 m/s
2
min.
100 A (EN60947-5-1)
2.5 A (EN60947-5-1)
−30
to 70°C (with no icing)
95% max.
UL2464 No. 22 AWG, finishing O.D.: 7.2 mm
Approx. 120 g (D4GS-N1R, with 1 m cable)
Conditional short-circuit current
Conventional free air thermal current (I
th
)
Ambient operating temperature
Ambient operating humidity
Cable
Weight
Note: 1.
The above values are initial values.
2.
The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however,
they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability
for smaller loads may be reduced.
*1.
The degree of protection shown above is based on the test method specified in EN60947-5-1. Be sure to confirm in advance the sealing
performance under the actual operating environment and conditions.
Although the switch box is protected from dust, oil, or water penetration, do not use the D4GS-N in places where dust, oil, water, or chemicals
may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2.
The durability conditions are an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
*3.
When the ambient temperature is 35°C or higher, do not apply 1 A at 125 VAC to more than one circuit.
*4.
These figures are minimum requirements for safe operation.
*5.
The value given for minimum applicable load is a reference value for microloads. The value will vary depending on factors such as the switching
frequency, the ambient environment, and the reliability level. Be sure to confirm correct operation with the actual load before application.
3
D4GS-N
Structure and Nomenclature
Structure
Head
The insertion direction of
the Operation Key can be
changed to either vertical
or horizontal.
(The figure shows a horizontal insertion.)
Built-in Switch
Switches are available with 2 or 3 contacts.
Mounting
Reversible design allowing
either front or rear mounting.
IP67 degree of protection
Model and Contact Configuration
(Diagrams Show State with Key Inserted.)
Model
Contact
Contact form
11-12
33-34
Operating pattern
ON
Stroke
Operation
Key insertion
completion
position
Extraction
completion
position
Remarks
D4GS-N1@-@
1NC/1NO
11
33
12
34
Only NC contact 11-12 has a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
11-12
31-32
ON
Stroke
D4GS-N2@-@
2NC
11
31
12
32
NC contacts 11-12 and 31-32
have a certified direct opening
mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
Operation
Key insertion
completion
position
Extraction
completion
position
11
12
22
34
D4GS-N3@-@
2NC/1NO
11-12
21-22
33-34
Stroke
Operation
Key insertion
completion
position
Extraction
completion
position
ON
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22 and
33-34 can be used as unlike
poles.
NC contacts 11-12, 21-22
and 31-32 have a certified
direct opening mechanism.
The terminals 11-12, 21-22 and
31-32 can be used as unlike
poles.
21
33
11
12
22
32
D4GS-N4@-@
3NC
11-12
21-22
31-32
Stroke
Operation
Key insertion
completion
position
Extraction
completion
position
ON
21
31
4
D4GS-N
Dimensions and Operating Characteristics
Switches
D4GS-N@R-@
Red
(Unit: mm)
Black
2.15±0.05R
mounting
hole:
(Operation Key
center position)
UL Style 2464
AWG22
Finishing O.D.: 7.2 mm dia.
Operating characteristics
Key insertion force
Key extraction force
Pretravel (PT)
Movement before being locked
15 N max.
30 N max.
6.8±3 mm
(22 mm)
D4GS-N@T-@
Red
8.4 (Operation Key center position)
Black
2.15±0.05R
mounting
hole:
UL Style 2464
AWG22
Finishing O.D.: 7.2 mm dia.
Note: 1.
Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions. Dimensions in parentheses are reference values.
2.
There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance
before application.
5